6.7.2 SC500 (ENGINE: FUSING)


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC530-00

D

Fusing Exhaust Fan Lock

In the motor ON state, the value of the lock sensor is checked every 0.1 sec.

If a lock signal is not obtained for 50 times consecutively.

Motor defective

Connector disconnected

Harness broken

IOB defective

Replace the fusing exhaust fan.

Reconnect the connector.

Replace the harness.

Replace the paper transport IOB.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC531-01

D

Development Intake Fan/Right Lock

SC531-03

D

Drive Cooling Fan Lock



In the motor ON state, the value of the lock sensor is checked every 0.1 sec.

If a lock signal is not obtained for 50 times consecutively.

Motor defective

Connector disconnected

Harness broken

IOB defective

Replace the development intake fan/right for SC531-01, or drive cooling fan for SC531-03.

Reconnect the connector.

Replace the harness.

Replace the imaging IOB.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC533-03

D

PSU Cooling Fan Lock

SC533-04

D

Controller Box Cooling Fan Lock



In the motor ON state, the value of the lock sensor is checked every 0.1 sec.

If a lock signal is not obtained for 50 times consecutively.

Motor defective

Connector disconnected

Harness broken

IOB defective

Replace the PSU exhaust fan for SC533-01, PSU cooling fan for SC533-04 or controller box cooling fan for

SC533-04.

Reconnect the connector.

Replace the harness.

Replace the paper transport IOB (for SC533-01, -03).

Replace the imaging IOB (for SC533-04).



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC534-01

D

Main Exhaust Fan Lock

SC534-02

D

Toner Supply Cooling Fan Lock

SC534-03

D

Ozone Exhaust Fan Lock



In the motor ON state, the value of the lock sensor is checked every 0.1 sec.

If a lock signal is not obtained for 50 times consecutively.

Motor defective

Connector disconnected

Harness broken

IOB defective

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



Replace the development intake fan/right for SC534-01, or drive cooling fan for SC534-03.

Reconnect the connector.

Replace the harness.

Replace the imaging IOB (SC534-01, -02).

Replace the paper transport IOB (for SC534-03).



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC535-00

D

Paper Exit Cooling Fan Lock

In the motor ON state, the value of the lock sensor is checked every 0.1 sec.

If a lock signal is not obtained for 50 times consecutively.

Motor defective

Connector disconnected

Harness broken

IOB defective

Replace the paper exit cooling fan.

Reconnect the connector.

Replace the harness.

Replace the imaging IOB.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC540-00

D

Fusing Motor: Lock

Motor status is observed at 0.1 sec intervals during motor ON, and the unlock status is detected at least 20 times.

Motor defective

Connector disconnected

Harness broken

IOB defective

Unit torque increased

Replace the fusing motor.

Reconnect the connector.

Replace the harness.

Replace the paper transport IOB.

 

Fusing Sleeve (Center) Error (SC54*-**)Fusing Sleeve (Edge) Error (SC55*-**)Pressure Roller Thermistor (Center) Error (SC56*-**)Pressure Roller Thermistor (Edge) Error (SC57*-**)Pressure Roller Thermistor (Full-bleed edge) Error (SC58*-**)