HOME PAGE | < Previous | Contents | Next >
6.7.2 SC500 (ENGINE: FUSING)
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC530-00 | D | Fusing Exhaust Fan Lock |
In the motor ON state, the value of the lock sensor is checked every 0.1 sec. If a lock signal is not obtained for 50 times consecutively. | ||
Motor defective Connector disconnected Harness broken IOB defective | ||
Replace the fusing exhaust fan. Reconnect the connector. Replace the harness. Replace the paper transport IOB. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC531-01 | D | Development Intake Fan/Right Lock |
SC531-03 | D | Drive Cooling Fan Lock |
In the motor ON state, the value of the lock sensor is checked every 0.1 sec. If a lock signal is not obtained for 50 times consecutively. | ||
Motor defective Connector disconnected Harness broken IOB defective | ||
Replace the development intake fan/right for SC531-01, or drive cooling fan for SC531-03. Reconnect the connector. Replace the harness. Replace the imaging IOB. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC533-03 | D | PSU Cooling Fan Lock |
SC533-04 | D | Controller Box Cooling Fan Lock |
In the motor ON state, the value of the lock sensor is checked every 0.1 sec. If a lock signal is not obtained for 50 times consecutively. | ||
Motor defective Connector disconnected Harness broken IOB defective | ||
Replace the PSU exhaust fan for SC533-01, PSU cooling fan for SC533-04 or controller box cooling fan for SC533-04. Reconnect the connector. Replace the harness. Replace the paper transport IOB (for SC533-01, -03). Replace the imaging IOB (for SC533-04). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC534-01 | D | Main Exhaust Fan Lock |
SC534-02 | D | Toner Supply Cooling Fan Lock |
SC534-03 | D | Ozone Exhaust Fan Lock |
In the motor ON state, the value of the lock sensor is checked every 0.1 sec. If a lock signal is not obtained for 50 times consecutively. | ||
Motor defective Connector disconnected Harness broken IOB defective |
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
Replace the development intake fan/right for SC534-01, or drive cooling fan for SC534-03. Reconnect the connector. Replace the harness. Replace the imaging IOB (SC534-01, -02). Replace the paper transport IOB (for SC534-03). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC535-00 | D | Paper Exit Cooling Fan Lock |
In the motor ON state, the value of the lock sensor is checked every 0.1 sec. If a lock signal is not obtained for 50 times consecutively. | ||
Motor defective Connector disconnected Harness broken IOB defective | ||
Replace the paper exit cooling fan. Reconnect the connector. Replace the harness. Replace the imaging IOB. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC540-00 | D | Fusing Motor: Lock |
Motor status is observed at 0.1 sec intervals during motor ON, and the unlock status is detected at least 20 times. | ||
Motor defective Connector disconnected Harness broken IOB defective Unit torque increased | ||
Replace the fusing motor. Reconnect the connector. Replace the harness. Replace the paper transport IOB. |