Pressure Roller Thermistor (Center) Error (SC56*-**)


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC561-01

A

Pressure Roller Thermistor (Center) Disconnection

SC561-05

D

Pressure Roller Thermistor (Center) Disconnection (Low Power)



Below 0 degree C detected for 20 sec continuously. Detection period 0.1 sec, detection count: 10 times or more.

Non-contact thermistor disconnection

Connector disconnected

Harness disconnection in the fusing unit

Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board)

BCU defective

Fusing lamp defective

AC controller board defective

1. Check the power supply voltage and reconnect the cable to the outlet. (-05 only)

2. Reconnect the connectors (between the fusing unit and the BCU).

3. Replace the thermistor.

4. Replace the fusing unit.

5. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

6. Replace the BCU.

7. Replace the fusing sleeve belt unit.

8. Replace the PSU (AC controller board).

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC562-02

A

Pressure Roller Thermistor (Center) Does Not Reload

SC562-05

D

Pressure Roller Thermistor (Center) Does Not Reload (Low Power)



Does not reach 40 degree C after fusing lamp 1ON for 12 sec.

Outside input voltage guarantee

Thermistor dirt

Thermistor modification/float

After excessive temperature rise prevention unit operation

Fusing lamp disconnection

Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board)

Thermopile defective

BCU defective

AC controller board defective

1. Check the power supply voltage and reconnect the cable to the outlet.

2. Clean or replace the thermistor.

3. Replace the fusing sleeve thermostat.

4. Replace the fusing sleeve belt unit.

5. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

6. Replace the thermopile (center).

7. Replace the BCU.

8. Replace the PSU (AC controller board).

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC563-00

A

Pressure Roller Thermistor (Center) High Temperature Detection (software)

Above 230 degrees C detected for 1 sec continuously. Detection period: 0.1 sec, detection count: 10 times or more.

Paper setting misdetection

Incorrect paper position in the paper feed tray

Jammed paper between the center thermopile and fusing unit

Thermopile lens dirt

Thermopile modification/float

Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board)

Triac defective (short-circuit)

BCU failure

AC controller board failure

1. Check the paper settings.

2. Check the paper position in the paper feed tray.

3. Reconnect the connectors (main machine side, BCU side).

4. Remove the jammed paper between the center thermopile and fusing unit.

5. Clean or replace the thermopile (center).

6. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

7. Replace the BCU.

8. Replace the PSU (AC controller board).

If the problem cannot be solved after performing the above steps, replace the fusing unit.

Service Call 501-584



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC564-00

A

Pressure Roller Thermistor (Center) High Temperature Detection (Hardware)

Above 240 degrees C detected.

Paper setting misdetection

Incorrect paper position in the paper feed tray

Jammed paper between the center thermopile and fusing unit

Thermopile lens dirt

Thermopile modification/float

Pressure roller HP sensor disconnected

Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board)

Triac defective (short-circuit)

BCU failure

AC controller board failure

1. Check the paper settings.

2. Check the paper position in the paper feed tray.

3. Reconnect the connectors (main machine side, BCU side).

4. Remove the jammed paper between the center thermopile and fusing unit.

5. Clean or replace the thermopile (center).

6. Inspect the pressure roller HP sensor with SP5-803-047.

7. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

8. Replace the BCU.

9. Replace the PSU (AC controller board).

If the problem cannot be solved after performing the above steps, replace the fusing unit.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC569-00

D

Paper Exit/ Pressure Release Motor Error Detection

Retry operation fails 3 times consecutively.

Pressure roller HP sensor disconnected

Pressure release encoder modification

Fusing unit defective

Paper exit/ pressure release motor disconnected

Inspect the pressure roller HP sensor with SP5-803-047. If no response from the sensor, perform steps 1 and 2.

1. Check the connection of the pressure roller HP sensor.

2. Inspect the pressure roller HP sensor.

3. Inspect the pressure release encoder.

4. Replace the fusing unit.

5. Check the connectors of the paper exit/ pressure release motor.