Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC547-03

D

Zero cross error (low-frequency error)

Mains power supply frequency is determined to be 44 Hz or lower.

Frequency instability of mains power supply

1. Check that the mains power supply frequency is higher than 44 Hz. If it is equal to or lower than 44 Hz, infrastructure may have defects to be dealt with.

2. Replace the PSU (AC controller board).


Fusing Sleeve (Edge) Error (SC55*-**)


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC551-01

A

Thermopile (Edge) Disconnection

Below -50 degrees C (or below CB) is detected for 0.1 sec continuously.

Thermopile disconnection

Connector disconnected

Harness disconnection between the fusing unit and the BCU

BCU defective

1. Reconnect the connectors (main machine side, BCU side).

2. Replace the thermopile (edge).

3. Replace the harness between the fusing unit and the BCU.

4. Replace the BCU.

SC551-02

A

Non-contact Thermistor (Edge) Disconnection

Above 3F6 is detected for 1 sec continuously (NC sensor center: detection & compensation NC sensor edge: detection & compensation).

Detection period: 0.1 sec, detection frequency: 10 times or more.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



Non-contact thermistor disconnection

Connector disconnected

Harness disconnection in the fusing unit

Harness disconnection between the fusing unit and the BCU

BCU defective

1. Reconnect the connectors (between the fusing unit and the BCU).

2. Replace the non-contact thermistor with the harness.

3. Replace the fusing unit.

4. Replace the harness between the fusing unit and the BCU.

5. Replace the BCU.

SC551-03

A

Non-contact Thermistor (Edge) Short-circuit

Below AD value: 8 is detected for 1 sec. continuously. Detection period: 0.1 sec, detection frequency: 10 times or more.

Non-contact thermistor short-circuit

Connector disconnected

Harness disconnection in the fusing unit

Harness disconnection between the fusing unit and the BCU

BCU defective

1. Reconnect the connectors (between the fusing unit and the BCU).

2. Replace the non-contact thermistor with the harness.

3. Replace the fusing unit.

4. Replace the harness between the fusing unit and the BCU.

5. Replace the BCU.

Service Call 501-584



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC552-02

A

Thermopile (Edge) Does Not Reload

65 degrees C not reached after fusing lamp 1 ON for 14 sec continuously.

SC552-03

A

Thermopile (Edge) Does Not Reload

Heating edge reload permission temperature not reached after fusing lamp 1 ON for 28 sec continuously.

SC552-05

D

Thermopile (Edge) Does Not Reload (Low Power)

65 degrees C not reached after fusing lamp 1 ON for 14 sec continuously.

SC552-06

D

Thermopile (Edge) Does Not Reload (Low Power)

Heating edge reload permission temperature not reached after fusing lamp 1 ON for 28 sec continuously.



Outside input voltage guarantee

Jammed paper between the thermopile and fusing unit

Thermopile lens dirt

Thermopile modification/float

After excessive temperature rise prevention unit operation

Fusing lamp disconnection

Harness disconnection between the fusing unit and BCU or the PSU (AC controller board)

BCU defective

AC controller board defective

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



1. Check the power supply voltage and reconnect the cable to the outlet.

2. Remove the jammed paper between the thermopile and fusing unit.

3. Clean or replace the thermopile (edge).

4. Replace the fusing sleeve thermostat.

5. Reconnect the fusing sleeve belt unit.

6. Reconnect or replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

7. Replace the BCU.

8. Replace the PSU (AC controller board).



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC553-00

A

Thermopile (Edge) High Temperature Detection (software)

Above 240 degrees C detected for 1 sec continuously. Detection period: 0.1 sec, detection count: 10 times or more.

Fusing sleeve belt defective

Paper setting misdetection

Incorrect paper position in the paper feed tray

Gear abrasion

Thermopile failure

Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board)

Triac defective (short-circuit)

BCU failure

AC controller board failure

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



1. Inspect the fusing sleeve belt unit, and replace if damaged.

2. Check the paper settings.

3. Check the paper position in the paper feed tray.

4. Reconnect the connectors (main machine side, BCU side).

5. Inspect or replace the gears in the fusing unit or main machine.

6. Replace the thermopile (edge).

7. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

8. Replace the BCU.

9. Replace the PSU (AC controller board).

If the problem cannot be solved after performing the above steps, replace the fusing unit.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC554-01

A

Thermopile (Edge) high temperature detection (hardware)

In the event of an error

Fusing sleeve belt defective

Paper setting misdetection

Incorrect paper position in the paper feed tray

Gear abrasion

Pressure roller HP sensor disconnected

Thermopile failure

Harness disconnection between the fusing unit and the BCU

Triac defective (short-circuit)

BCU failure

AC controller board failure

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



1. Inspect the fusing sleeve belt unit, and replace if damaged.

2. Check the paper settings.

3. Check the paper position in the paper feed tray.

4. Reconnect the connectors (main machine side, BCU side).

5. Inspect or replace the gears in the fusing unit or main machine.

6. Inspect the pressure roller HP sensor with SP5-803-047.

7. Replace the thermopile (edge).

8. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

9. Replace the BCU.

10. Replace the PSU (AC controller board).

If the problem cannot be solved after performing the above steps, replace the fusing unit.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC554-02

A

Non-contact Thermistor (Edge) high temperature detection (hardware)

In the event of an error

Fusing sleeve belt defective

Paper setting misdetection

Incorrect paper position in the paper feed tray

Jammed paper between the thermopile and fusing unit

Thermopile lens dirt

Thermopile modification/float

Pressure roller HP sensor disconnected

Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board)

Triac defective (short-circuit)

BCU failure

AC controller board failure

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



1. Inspect the fusing sleeve belt unit, and replace if damaged.

2. Check the paper settings.

3. Check the paper position in the paper feed tray.

4. Reconnect the connectors (main machine side, BCU side).

5. Remove the jammed paper between the thermopile and fusing unit.

6. Clean or replace the thermopile (edge).

7. Replace the fusing unit.

8. Inspect the pressure roller HP sensor with SP5-803-047.

9. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

10. Replace the BCU.

11. Replace the PSU (AC controller board).



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC555-01

A

Fusing Edge Lamp Continuously Heat

SC555-05

D

Fusing Edge Lamp Continuously Heat (Low Power)



After waiting for full power for more than 5 sec continuously.

Definition of fusing lamp full power

Continuously heating rate set point (maximum heating rate)

Measurement start point

After reload (after fusing lamp extinguished, after rotation complete) below the standby temperature (target temperature), measurement starts after a fusing lamp heat-up request is issued.

Measurement stop condition

Rotation started due to a print signal during measurement or other

Maximum heat-up Duty (SP interlinked value) 0% is excluded

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 501-584


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



Outside input voltage guarantee

Jammed paper between the thermopile and fusing unit

Thermopile lens dirt

Thermopile modification/float

After excessive temperature rise prevention unit operation

Fusing lamp disconnection

Harness disconnection between the fusing unit and the BCU

BCU defective

AC controller board defective

1. Check the power supply voltage and reconnect the cable to the outlet.

2. Remove the jammed paper between the thermopile and fusing unit.

3. Clean or replace the thermopile (edge).

4. Replace the fusing sleeve thermostat.

5. Replace the fusing sleeve belt unit.

6. Reconnect or replace the harness between the fusing unit and the BCU or the PSU (AC controller board).

7. Replace the BCU.

8. Replace the PSU (AC controller board).



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC557-00

C

Zero Cross Frequency Exceeded

In the event of an error

Frequency instability of mains power supply /Noise

-

Service Call 501-584



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC558-01

C

Low Input Voltage

Input voltage below the specification is detected on the mains power supply

Low input of mains power supply

-



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC559-00

A

Fusing Jam Detected for 3 Times Consecutively

Fusing jam (does not reach fusing exit sensor) is detected for 3 times consecutively.

Detection conditions

Displays the SC559-00 at the time of integrating the counter each time fusing jam occurs, became fusing jam counter value = 3.

The counter value is retained without fusing jam also reset by OFF/ON the power supply.

Control ON/OFF

And enables ON / OFF is this SC, the default is set to OFF, then ON at the time of customer requirements.

SP1-142-001 0: OFF (default), 1: ON (Set at the time of customer requirements)

Counter reset condition occurs fusing jam

1. Normal paper exit has been done during this continuous fusing jam, fusing jam counter is reset.

2. When "1" is changed to "0" SP1-142-001, to reset the (SP9-912-001) fusing jam counter.

3. When after displaying SC559, SC release is made, reset the (SP9912-001) fusing jam counter.



Stripper plate float/ mounting failure

Gear abrasion

Fusing motor failure

Troubleshooting

Troubleshooting

Troubleshooting