SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC547-03 | D | Zero cross error (low-frequency error) |
Mains power supply frequency is determined to be 44 Hz or lower. | ||
Frequency instability of mains power supply | ||
1. Check that the mains power supply frequency is higher than 44 Hz. If it is equal to or lower than 44 Hz, infrastructure may have defects to be dealt with. 2. Replace the PSU (AC controller board). |
Fusing Sleeve (Edge) Error (SC55*-**)
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC551-01 | A | Thermopile (Edge) Disconnection |
Below -50 degrees C (or below CB) is detected for 0.1 sec continuously. | ||
Thermopile disconnection Connector disconnected Harness disconnection between the fusing unit and the BCU BCU defective | ||
1. Reconnect the connectors (main machine side, BCU side). 2. Replace the thermopile (edge). 3. Replace the harness between the fusing unit and the BCU. 4. Replace the BCU. | ||
SC551-02 | A | Non-contact Thermistor (Edge) Disconnection |
Above 3F6 is detected for 1 sec continuously (NC sensor center: detection & compensation NC sensor edge: detection & compensation). Detection period: 0.1 sec, detection frequency: 10 times or more. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
Non-contact thermistor disconnection Connector disconnected Harness disconnection in the fusing unit Harness disconnection between the fusing unit and the BCU BCU defective | ||
1. Reconnect the connectors (between the fusing unit and the BCU). 2. Replace the non-contact thermistor with the harness. 3. Replace the fusing unit. 4. Replace the harness between the fusing unit and the BCU. 5. Replace the BCU. | ||
SC551-03 | A | Non-contact Thermistor (Edge) Short-circuit |
Below AD value: 8 is detected for 1 sec. continuously. Detection period: 0.1 sec, detection frequency: 10 times or more. | ||
Non-contact thermistor short-circuit Connector disconnected Harness disconnection in the fusing unit Harness disconnection between the fusing unit and the BCU BCU defective | ||
1. Reconnect the connectors (between the fusing unit and the BCU). 2. Replace the non-contact thermistor with the harness. 3. Replace the fusing unit. 4. Replace the harness between the fusing unit and the BCU. 5. Replace the BCU. |
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC552-02 | A | Thermopile (Edge) Does Not Reload |
65 degrees C not reached after fusing lamp 1 ON for 14 sec continuously. | ||
SC552-03 | A | Thermopile (Edge) Does Not Reload |
Heating edge reload permission temperature not reached after fusing lamp 1 ON for 28 sec continuously. | ||
SC552-05 | D | Thermopile (Edge) Does Not Reload (Low Power) |
65 degrees C not reached after fusing lamp 1 ON for 14 sec continuously. | ||
SC552-06 | D | Thermopile (Edge) Does Not Reload (Low Power) |
Heating edge reload permission temperature not reached after fusing lamp 1 ON for 28 sec continuously. | ||
Outside input voltage guarantee Jammed paper between the thermopile and fusing unit Thermopile lens dirt Thermopile modification/float After excessive temperature rise prevention unit operation Fusing lamp disconnection Harness disconnection between the fusing unit and BCU or the PSU (AC controller board) BCU defective AC controller board defective |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
1. Check the power supply voltage and reconnect the cable to the outlet. 2. Remove the jammed paper between the thermopile and fusing unit. 3. Clean or replace the thermopile (edge). 4. Replace the fusing sleeve thermostat. 5. Reconnect the fusing sleeve belt unit. 6. Reconnect or replace the harness between the fusing unit and the BCU or the PSU (AC controller board). 7. Replace the BCU. 8. Replace the PSU (AC controller board). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC553-00 | A | Thermopile (Edge) High Temperature Detection (software) |
Above 240 degrees C detected for 1 sec continuously. Detection period: 0.1 sec, detection count: 10 times or more. | ||
Fusing sleeve belt defective Paper setting misdetection Incorrect paper position in the paper feed tray Gear abrasion Thermopile failure Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board) Triac defective (short-circuit) BCU failure AC controller board failure |
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
1. Inspect the fusing sleeve belt unit, and replace if damaged. 2. Check the paper settings. 3. Check the paper position in the paper feed tray. 4. Reconnect the connectors (main machine side, BCU side). 5. Inspect or replace the gears in the fusing unit or main machine. 6. Replace the thermopile (edge). 7. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board). 8. Replace the BCU. 9. Replace the PSU (AC controller board). If the problem cannot be solved after performing the above steps, replace the fusing unit. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC554-01 | A | Thermopile (Edge) high temperature detection (hardware) |
In the event of an error | ||
Fusing sleeve belt defective Paper setting misdetection Incorrect paper position in the paper feed tray Gear abrasion Pressure roller HP sensor disconnected Thermopile failure Harness disconnection between the fusing unit and the BCU Triac defective (short-circuit) BCU failure AC controller board failure |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
1. Inspect the fusing sleeve belt unit, and replace if damaged. 2. Check the paper settings. 3. Check the paper position in the paper feed tray. 4. Reconnect the connectors (main machine side, BCU side). 5. Inspect or replace the gears in the fusing unit or main machine. 6. Inspect the pressure roller HP sensor with SP5-803-047. 7. Replace the thermopile (edge). 8. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board). 9. Replace the BCU. 10. Replace the PSU (AC controller board). If the problem cannot be solved after performing the above steps, replace the fusing unit. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC554-02 | A | Non-contact Thermistor (Edge) high temperature detection (hardware) |
In the event of an error | ||
Fusing sleeve belt defective Paper setting misdetection Incorrect paper position in the paper feed tray Jammed paper between the thermopile and fusing unit Thermopile lens dirt Thermopile modification/float Pressure roller HP sensor disconnected Harness disconnection between the fusing unit and the BCU or the PSU (AC controller board) Triac defective (short-circuit) BCU failure AC controller board failure |
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
1. Inspect the fusing sleeve belt unit, and replace if damaged. 2. Check the paper settings. 3. Check the paper position in the paper feed tray. 4. Reconnect the connectors (main machine side, BCU side). 5. Remove the jammed paper between the thermopile and fusing unit. 6. Clean or replace the thermopile (edge). 7. Replace the fusing unit. 8. Inspect the pressure roller HP sensor with SP5-803-047. 9. Replace the harness between the fusing unit and the BCU or the PSU (AC controller board). 10. Replace the BCU. 11. Replace the PSU (AC controller board). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC555-01 | A | Fusing Edge Lamp Continuously Heat |
SC555-05 | D | Fusing Edge Lamp Continuously Heat (Low Power) |
After waiting for full power for more than 5 sec continuously. Definition of fusing lamp full power Continuously heating rate set point (maximum heating rate) Measurement start point After reload (after fusing lamp extinguished, after rotation complete) below the standby temperature (target temperature), measurement starts after a fusing lamp heat-up request is issued. Measurement stop condition Rotation started due to a print signal during measurement or other Maximum heat-up Duty (SP interlinked value) 0% is excluded |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
Outside input voltage guarantee Jammed paper between the thermopile and fusing unit Thermopile lens dirt Thermopile modification/float After excessive temperature rise prevention unit operation Fusing lamp disconnection Harness disconnection between the fusing unit and the BCU BCU defective AC controller board defective | ||
1. Check the power supply voltage and reconnect the cable to the outlet. 2. Remove the jammed paper between the thermopile and fusing unit. 3. Clean or replace the thermopile (edge). 4. Replace the fusing sleeve thermostat. 5. Replace the fusing sleeve belt unit. 6. Reconnect or replace the harness between the fusing unit and the BCU or the PSU (AC controller board). 7. Replace the BCU. 8. Replace the PSU (AC controller board). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC557-00 | C | Zero Cross Frequency Exceeded |
In the event of an error | ||
Frequency instability of mains power supply /Noise | ||
- |
Service Call 501-584
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC558-01 | C | Low Input Voltage |
Input voltage below the specification is detected on the mains power supply | ||
Low input of mains power supply | ||
- |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC559-00 | A | Fusing Jam Detected for 3 Times Consecutively |
Fusing jam (does not reach fusing exit sensor) is detected for 3 times consecutively. Detection conditions Displays the SC559-00 at the time of integrating the counter each time fusing jam occurs, became fusing jam counter value = 3. The counter value is retained without fusing jam also reset by OFF/ON the power supply. Control ON/OFF And enables ON / OFF is this SC, the default is set to OFF, then ON at the time of customer requirements. SP1-142-001 0: OFF (default), 1: ON (Set at the time of customer requirements) Counter reset condition occurs fusing jam 1. Normal paper exit has been done during this continuous fusing jam, fusing jam counter is reset. 2. When "1" is changed to "0" SP1-142-001, to reset the (SP9-912-001) fusing jam counter. 3. When after displaying SC559, SC release is made, reset the (SP9912-001) fusing jam counter. | ||
Stripper plate float/ mounting failure Gear abrasion Fusing motor failure |
Troubleshooting
Troubleshooting
Troubleshooting