HOME PAGE | < Previous | Contents | Next >
PM Tables
Appendix: Preventive Maintenance Tables
Appendix: Preventive Maintenance Tables
Appendix: Preventive Maintenance Tables
EM | 160K | 320K | 800K | Note | |
Fusing Unit and Paper Exit | |||||
Fusing Entrance and Exit Guide Plates | C | Water or alcohol | |||
Hot Roller | R | ||||
Pressure Roller | R | ||||
Fusing Thermistors | R | ||||
Cleaning Roller Bushings | L | Grease: Barrierta JFE 55/2 | |||
Hot Roller Strippers | R | ||||
Web Supply Roller | R | ||||
Web Holder Roller | R | ||||
Brake Pad | R |
EM | 160K | 320K | 800K | Note | |
Fusing Unit and Paper Exit | |||||
Fusing Entrance and Exit Guide Plates | C | Water or alcohol | |||
Hot Roller | R | ||||
Pressure Roller | R | ||||
Fusing Thermistors | R | ||||
Cleaning Roller Bushings | L | Grease: Barrierta JFE 55/2 | |||
Hot Roller Strippers | R | ||||
Web Supply Roller | R | ||||
Web Holder Roller | R | ||||
Brake Pad | R |
EM | 160K | 320K | 800K | Note | |
Fusing Unit and Paper Exit | |||||
Fusing Entrance and Exit Guide Plates | C | Water or alcohol | |||
Hot Roller | R | ||||
Pressure Roller | R | ||||
Fusing Thermistors | R | ||||
Cleaning Roller Bushings | L | Grease: Barrierta JFE 55/2 | |||
Hot Roller Strippers | R | ||||
Web Supply Roller | R | ||||
Web Holder Roller | R | ||||
Brake Pad | R |
2.1.2 OPTIONS
Amounts mentioned as the PM interval indicate the number of prints/ originals. Symbol key: C: Clean, R: Replace, L: Lubricate, I: Inspect
SM Appendix 2-5 D129/D130