HOME PAGE | < Previous | Contents | Next >
6.20 OTHER TROUBLESHOOTING
6.20.1 WHEN FLUORESCENT/ LED LAMPS FLICKER
Problem
Under the usage environment of this machine, at the placement location, fluorescent and/or LED lamps flicker.
Causes
As a result of the voltage drop occurs, when the fusing lamp is applied an electrical current. It depends on the electrical power environment, at the customer's placement location.
Solutions
The procedure varies by the flicker occurrence timing. So check the occurrence timing, and do the procedure that matches the timing.
Occurrence Timing
Timing | Solutions | Side effect |
Recovery from energy saving | Set SP1-135-001 (Inrush Control) to "1 (ON)". | Recovery time from energy saving becomes slower approx. 0.4 sec.. |
Troubleshooting
Troubleshooting
Troubleshooting
Other Troubleshooting
Timing | Solutions | Side effect |
After the recovery from energy saving | Set SP1-135-001 (Inrush Control) to "1 (ON)". Set SP1-135-002 (Flicker Control) to "1 (ON)". | Recovery time from energy saving becomes slower approx. 0.4 sec.. In the case of the adhesion amount of an image is large, an offset may occur. In the case of a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed. |
If it has not been improved in the above, do the following procedures in addition; Stop the lighting of the fusing lamp after the warm-up. Set SP1-121-001 (Switch:Rotation Start/Stop:Time:After Reload) to "0 sec". | The fusing temperature drops during the operation. After copying starts, the fusing temperature is raised up to a printable temperature. Because of that, copying completion time becomes slower (approx. 1-2 sec.). | |
Printing | Set SP1-135-002 (Flicker Control) to "1 (ON)". | In the case of the adhesion amount of an image is large, an offset may occur. In the case of a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed. |
Related SP to Fusing Offsets
SP Name | SP No. | Value |
Print Target Temp.:Plain1:FC:Center | SP1-105-001 | As initial values + 10 °C are the upper limits, change values to improve offsets. |
Print Target Temp.:Plain1:BW:Center | SP1-105-003 | |
Print Target Temp.:Plain2:FC:Center | SP1-105-005 |
Other Troubleshooting
SP Name | SP No. | Value |
Print Target Temp.:Plain2:BW:Center | SP1-105-007 | |
Print Target Temp.: Thin:FC:Center | SP1-105-009 | |
Print Target Temp.: Thin:BW:Center | SP1-105-011 | |
Print Target Temp.: M-thick:FC:Center | SP1-105-013 | |
Print Target Temp.: M-thick:BW:Center | SP1-105-015 |