HOME PAGE | < Previous | Contents | Next >
6.19.3 WHEN AN ABNORMAL IMAGE IS GENERATED
Troubleshooting
Troubleshooting
Troubleshooting
Image Quality Problems
Interval | Target part | Replacement part |
31.4mm | Charge roller cleaner | PCU |
34.6mm | Development roller | Development unit |
37.7mm | Charge roller | PCU |
48.7mm | Paper transfer roller | Paper transfer roller unit |
54.8mm | Image transfer drive roller | Image transfer unit |
94.2mm | Drum | PCU |
94.2mm | Fusing sleeve belt | Fusing sleeve belt unit/ Fusing unit |
100.5mm | Pressure roller | Pressure roller/ Fusing unit |
963.8mm | Image transfer belt | Image transfer belt/ Image transfer unit |