HOME PAGE | < Previous | Contents | Next >

Other Troubleshooting


6.20 OTHER TROUBLESHOOTING


6.20.1 WHEN FLUORESCENT/ LED LAMPS FLICKER

Problem

Under the usage environment of this machine, at the placement location, fluorescent and/or LED lamps flicker.

Causes

As a result of the voltage drop occurs, when the fusing lamp is applied an electrical current. It depends on the electrical power environment, at the customer's placement location.

Solutions

The procedure varies by the flicker occurrence timing. So check the occurrence timing, and do the procedure that matches the timing.

Occurrence Timing


image


Timing

Solutions

Side effect

image Recovery from energy saving

Set SP1-135-001 (Inrush Control) to "1 (ON)".

Recovery time from energy saving becomes slower approx. 0.4 sec..

Troubleshooting

Troubleshooting

Troubleshooting

Other Troubleshooting


Timing

Solutions

Side effect

image After the recovery from energy saving

Set SP1-135-001 (Inrush Control) to "1 (ON)".

Set SP1-135-002 (Flicker Control) to "1 (ON)".

Recovery time from energy saving becomes slower approx. 0.4 sec..

In the case of the adhesion amount of an image is large, an offset may occur.

In the case of a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed.

If it has not been improved in the above, do the following procedures in addition;

Stop the lighting of the fusing lamp after the warm-up. Set

SP1-121-001

(Switch:Rotation Start/Stop:Time:After Reload) to "0 sec".

The fusing temperature drops during the operation. After copying starts, the fusing temperature is raised up to a printable temperature. Because of that, copying completion time becomes slower (approx. 1-2 sec.).

image Printing

Set SP1-135-002 (Flicker Control) to "1 (ON)".

In the case of the adhesion amount of an image is large, an offset may occur.

In the case of a fusing offset occurs, in the related SP to fusing offsets, setting values must be changed.


Related SP to Fusing Offsets


SP Name

SP No.

Value

Print Target Temp.:Plain1:FC:Center

SP1-105-001


As initial values + 10 °C are the upper limits, change values to improve offsets.

Print Target Temp.:Plain1:BW:Center

SP1-105-003

Print Target Temp.:Plain2:FC:Center

SP1-105-005

Other Troubleshooting


SP Name

SP No.

Value

Print Target Temp.:Plain2:BW:Center

SP1-105-007


Print Target Temp.: Thin:FC:Center

SP1-105-009

Print Target Temp.: Thin:BW:Center

SP1-105-011

Print Target Temp.: M-thick:FC:Center

SP1-105-013

Print Target Temp.: M-thick:BW:Center


SP1-105-015

Other Troubleshooting


Troubleshooting

Troubleshooting

Troubleshooting

DETAILED DESCRIPTIONS


RE V IS ION H IST ORY

Page

Date

Added/ Updated/ New



None