6.8.2 SC600 (CONTROLLER)
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC632-00 | D | Counter device error 1 |
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms. | ||
Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged. | ||
Turn the main power off/on. Check the serial communication line. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC633-00 | D | Counter device error 2 |
After communication was established, the controller received the brake signal from the accounting device. | ||
Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged. | ||
Turn the main power off/on. Check the serial communication line. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC634-00 | D | Counter device error 3 |
A backup RAM error was returned by the counter device. | ||
Counter device control board or the backup battery of counter device defective | ||
Replace the counter device control board. Replace the backup battery. |
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC635-00 | D | Counter device error 4 |
A backup battery error was returned by the counter device. | ||
Counter device control board or the backup battery of counter device defective | ||
Replace the counter device control board. Replace the backup battery. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC636-01 | D | IC Card Error (Expanded authentication module error) |
Issued when expanded authentication management is set to "ON" but either of the following occur. There is no expanded authentication module in the machine. The SD card or the file of the expanded authentication module is broken. There is no DESS module in the machine. | ||
There is no DESS module in the machine (models on which the function is optional). There is no expanded authentication module in the machine. The SD card or the file of the expanded authentication module is broken. | ||
Set a working SD card/expanded authentication module file. Install the DESS module. In the SSP mode set SP5-401-160 to "0". In the SSP mode, set SP5-401-161 to "0". Replace the NVRAM. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC636-02 | D | IC Card Error (Version error) |
The version of the expanded authentication module is not correct. | ||
Incorrect module version | ||
Install the correct file of the expanded authentication module. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC637-01 | D | Tracking Information Notification Error (Tracking application error) |
Tracking information was lost. | ||
Tracking SDK application error Internal notification error | ||
Turn the main power off/on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC637-02 | D | Tracking Information Notification Error (Management server error) |
Tracking information was lost. | ||
Communication with tracking management server failed. Network error tracking management server error Tracking SDK application error | ||
Turn the main power off/on. |
Service Call 620-687
SC No. | Type | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
SC641-00 | D | Communication error between BCU and Controller board. |
Controller board does not respond after BCU tries to communicate three times. | ||
Controller board software error Connect error between BCU and Controller board Engine board software error | ||
Check connections between Controller board and BCU. Turn the main switch off and on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC650-01 | C | Remote Service Modem Communication Error (Dialup authentication failure) |
An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. Displayed only when an error is detected while RC Gate is operating. SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP). | ||
Dialup authentication failure | ||
Check the following SPs. SP5-816-156 SP5-816-157 |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC650-04 | C | Remote Service Modem Communication Error (dialup failing because of incorrect modem configuration) |
An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. Displayed only when an error is detected while RC Gate is operating. SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP). | ||
Dialup failing because of incorrect modem configuration | ||
Check if the setting of SP5-816-160 is correct. If it is correct, then there is a software bug. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC650-05 | C | Remote Service Modem Communication Error (insufficient current or connection error) |
An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. Displayed only when an error is detected while RC Gate is operating. SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP). | ||
Insufficient current or connection error | ||
The line is not supported and nothing can be done. |
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC650-13 | C | Remote Service Modem Communication Error (RC Gate Type M was installed but modem is not present (detected during operation)) |
An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on. Displayed only when an error is detected while RC Gate is operating. SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP). | ||
RC Gate Type M was installed but modem is not present (detected during operation) | ||
If a modem board is not installed, install it. Check again if the modem driver configurations (SP5-816-160, SP5-816-165 to 171) are correct. If the problem is not solved, replace the modem. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC650-14 | C | Remote Service Modem Communication Error (RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly) |
An error related to communication (dialup connection, modem board etc.) using the RC Gate was detected or an error that prevents RC Gate operation was detected at power on. Displayed only when an error is detected while RC Gate is operating. SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP). | ||
RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly |
Troubleshooting
Troubleshooting
Troubleshooting
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
If a modem board is attached, remove it. Check if wired/wireless LAN works. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
If a modem board is attached, remove it. Check if wired/wireless LAN works. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
If a modem board is attached, remove it. Check if wired/wireless LAN works. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC651-01 | C | Illegal Remote Service Dial-up (Chat program parameter error) |
An unexpected error occurred when RC Gate Type M dialed up the NRS Center. | ||
Software bug | ||
Logging only. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC651-01 | C | Illegal Remote Service Dial-up (Chat program parameter error) |
An unexpected error occurred when RC Gate Type M dialed up the NRS Center. | ||
Software bug | ||
Logging only. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC651-01 | C | Illegal Remote Service Dial-up (Chat program parameter error) |
An unexpected error occurred when RC Gate Type M dialed up the NRS Center. | ||
Software bug | ||
Logging only. |
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC651-02 | C | Illegal Remote Service Dial-up (Chat program execution error) |
An unexpected error occurred when RC Gate dialed up the NRS Center. | ||
Software bug | ||
Logging only. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC652-00 | A | Remote service ID2 mismatching |
There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM. | ||
Used controller board installed Used NVRAM installed (such action is not allowed.) |
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
If this occurs during RC Gate installation: Check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again. If this occurs after RC Gate installation: Clear the RC Gate install status, check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC653-00 | A | Incorrect remote service ID2 |
ID2 stored in the NVRAM has either of the following problems. Number of characters is not 17. Includes a character that cannot be printed. All spaces NULL | ||
Replace the NVRAM. | ||
Clear the RC Gate install status, write the common certificate, and then begin installation again. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC670-01 | D | Engine start up error when the machine boots up |
/ENGRDY signal was not asserted when the machine was turned on. PCI I/F is not linked up when the machine returns from energy saver mode. /IPURDY signal was not asserted when the machine was turned on or returned from energy saver mode. EC/PC/SC response was not received within specified time from power on. Writing to Rapi driver failed (the other party not found through PCI). Connection defect between controller board and IPU. IPU is down / unstable BCU is down / unstable | ||
Engine board does not start up. | ||
Refer to page 6-227 "When SC670 (Engine start up error) is displayed". |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC670-02 | D | Engine start up error when the machine is in operation |
CPU reset by software CPU reset by anomaly CPU CPU reset by hardware defect / noise Hardware defect | ||
Engine board reset unexpectedly. | ||
Refer to page 6-227 "When SC670 (Engine start up error) is displayed". |
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC670-03 | D | IPU start up error when the machine boots up |
VDET_EPCI signal was not asserted when the machine was turned on. | ||
IPU, PSU, and/or CTL defective Incorrect connection between CTL and IPU. Harness of IPU disconnected | ||
Refer to page 6-227 "When SC670 (Engine start up error) is displayed". |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC670-04 | D | Communication error between the engine and controller |
Communication could not linked up. | ||
IPU and/or CTL defective Incorrect connection between CTL and IPU. | ||
Refer to page 6-227 "When SC670 (Engine start up error) is displayed". |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC672-10 | D | Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established. | ||
Controller stalled Board installed incorrectly Controller board defective Operation panel connector loose, broken, or defective Controller late | ||
Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed". |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC672-11 | D | Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. | ||
Controller stalled Board installed incorrectly Controller board defective Operation panel connector loose, broken, or defective Controller late | ||
Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed". |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC672-12 | D | Controller start up error |
Communication with controller was interrupted after a normal startup. | ||
Controller stalled Board installed incorrectly Controller board defective Operation panel connector loose, broken, or defective Controller late | ||
Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed". |
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC672-13 | D | Controller start up error |
The operation panel detects that the controller is down due to other reason shown in SC672-10, SC672-11, and SC672-12. | ||
Controller stalled Board installed incorrectly Controller board defective Operation panel connector loose, broken, or defective Controller late | ||
Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed". |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC672-99 | D | Controller start up error |
The operation panel software ended abnormally. | ||
Controller stalled Board installed incorrectly Controller board defective Operation panel connector loose, broken, or defective Controller late | ||
Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed". |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-687
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC673-10 | D | Operation panel Flair communication error (Smart Operation Panel) |
This SC is issued only for the machine that has the Smart Operation Panel installed. Communication between Smart Operation Panel and main machine (this is called "Flair communication") is not sent to Smart Operation Panel. SP setting (SP5-748-201) for Smart Operation Panel is not activated. | ||
The CATS module (controller) did not see the response to notification of monitoring service module (operation panel). | ||
Turn the main power OFF/ON. Set SP5-748-201 (OpePanel Setting: Cheetah Panel Connect Setting) to "1: Connect" if the value is "0: Not connect". |