Service Call 620-687


Troubleshooting

Troubleshooting

Troubleshooting

6.8.2 SC600 (CONTROLLER)


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC632-00

D

Counter device error 1

After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.

Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged.

Turn the main power off/on.

Check the serial communication line.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC633-00

D

Counter device error 2

After communication was established, the controller received the brake signal from the accounting device.

Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged.

Turn the main power off/on.

Check the serial communication line.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC634-00

D

Counter device error 3

A backup RAM error was returned by the counter device.

Counter device control board or the backup battery of counter device defective

Replace the counter device control board.

Replace the backup battery.

Service Call 620-687


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC635-00

D

Counter device error 4

A backup battery error was returned by the counter device.

Counter device control board or the backup battery of counter device defective

Replace the counter device control board.

Replace the backup battery.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC636-01

D

IC Card Error (Expanded authentication module error)

Issued when expanded authentication management is set to "ON" but either of the following occur.

There is no expanded authentication module in the machine.

The SD card or the file of the expanded authentication module is broken.

There is no DESS module in the machine.

There is no DESS module in the machine (models on which the function is optional).

There is no expanded authentication module in the machine.

The SD card or the file of the expanded authentication module is broken.

Set a working SD card/expanded authentication module file.

Install the DESS module.

In the SSP mode set SP5-401-160 to "0".

In the SSP mode, set SP5-401-161 to "0".

Replace the NVRAM.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 620-687



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC636-02

D

IC Card Error (Version error)

The version of the expanded authentication module is not correct.

Incorrect module version

Install the correct file of the expanded authentication module.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC637-01

D

Tracking Information Notification Error (Tracking application error)

Tracking information was lost.

Tracking SDK application error

Internal notification error

Turn the main power off/on.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC637-02

D

Tracking Information Notification Error (Management server error)

Tracking information was lost.

Communication with tracking management server failed.

Network error

tracking management server error

Tracking SDK application error

Turn the main power off/on.

Service Call 620-687




SC No.


Type

Details (Symptom, Possible Cause, Troubleshooting Procedures)

SC641-00

D

Communication error between BCU and Controller board.

Controller board does not respond after BCU tries to communicate three times.

Controller board software error

Connect error between BCU and Controller board

Engine board software error

Check connections between Controller board and BCU.

Turn the main switch off and on.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-01

C

Remote Service Modem Communication Error (Dialup authentication failure)

An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.

Displayed only when an error is detected while RC Gate is operating.

SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).

Dialup authentication failure

Check the following SPs.

SP5-816-156

SP5-816-157

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 620-687



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-04

C

Remote Service Modem Communication Error (dialup failing because of incorrect modem configuration)

An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.

Displayed only when an error is detected while RC Gate is operating.

SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).

Dialup failing because of incorrect modem configuration

Check if the setting of SP5-816-160 is correct. If it is correct, then there is a software bug.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-05

C

Remote Service Modem Communication Error (insufficient current or connection error)

An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.

Displayed only when an error is detected while RC Gate is operating.

SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).

Insufficient current or connection error

The line is not supported and nothing can be done.

Service Call 620-687


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-13

C

Remote Service Modem Communication Error (RC Gate Type M was installed but modem is not present (detected during operation))

An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.

Displayed only when an error is detected while RC Gate is operating.

SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).

RC Gate Type M was installed but modem is not present (detected during operation)

If a modem board is not installed, install it.

Check again if the modem driver configurations (SP5-816-160, SP5-816-165 to 171) are correct.

If the problem is not solved, replace the modem.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-14

C

Remote Service Modem Communication Error (RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly)

An error related to communication (dialup connection, modem board etc.) using the RC Gate was detected or an error that prevents RC Gate operation was detected at power on.

Displayed only when an error is detected while RC Gate is operating.

SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).

RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly

Troubleshooting

Troubleshooting

Troubleshooting

SC No.

Type

Error Name/Error Condition/Major Cause/Solution



If a modem board is attached, remove it.

Check if wired/wireless LAN works.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution



If a modem board is attached, remove it.

Check if wired/wireless LAN works.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution



If a modem board is attached, remove it.

Check if wired/wireless LAN works.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC651-01

C

Illegal Remote Service Dial-up (Chat program parameter error)

An unexpected error occurred when RC Gate Type M dialed up the NRS Center.

Software bug

Logging only.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC651-01

C

Illegal Remote Service Dial-up (Chat program parameter error)

An unexpected error occurred when RC Gate Type M dialed up the NRS Center.

Software bug

Logging only.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC651-01

C

Illegal Remote Service Dial-up (Chat program parameter error)

An unexpected error occurred when RC Gate Type M dialed up the NRS Center.

Software bug

Logging only.

Service Call 620-687


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC651-02

C

Illegal Remote Service Dial-up (Chat program execution error)

An unexpected error occurred when RC Gate dialed up the NRS Center.

Software bug

Logging only.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC652-00

A

Remote service ID2 mismatching

There was an authentication mismatch between ID2 for

@Remote, the controller board, and NVRAM.

Used controller board installed

Used NVRAM installed (such action is not allowed.)

Service Call 620-687


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



If this occurs during RC Gate installation:

Check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again.

If this occurs after RC Gate installation:

Clear the RC Gate install status, check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC653-00

A

Incorrect remote service ID2

ID2 stored in the NVRAM has either of the following problems.

Number of characters is not 17.

Includes a character that cannot be printed.

All spaces

NULL

Replace the NVRAM.

Clear the RC Gate install status, write the common certificate, and then begin installation again.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 620-687



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-01

D

Engine start up error when the machine boots up

/ENGRDY signal was not asserted when the machine was turned on.

PCI I/F is not linked up when the machine returns from energy saver mode.

/IPURDY signal was not asserted when the machine was turned on or returned from energy saver mode.

EC/PC/SC response was not received within specified time from power on.

Writing to Rapi driver failed (the other party not found through PCI).

Connection defect between controller board and IPU.

IPU is down / unstable

BCU is down / unstable

Engine board does not start up.

Refer to page 6-227 "When SC670 (Engine start up error) is displayed".



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-02

D

Engine start up error when the machine is in operation

CPU reset by software

CPU reset by anomaly CPU

CPU reset by hardware defect / noise

Hardware defect

Engine board reset unexpectedly.

Refer to page 6-227 "When SC670 (Engine start up error) is displayed".

Service Call 620-687



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-03

D

IPU start up error when the machine boots up

VDET_EPCI signal was not asserted when the machine was turned on.

IPU, PSU, and/or CTL defective

Incorrect connection between CTL and IPU.

Harness of IPU disconnected

Refer to page 6-227 "When SC670 (Engine start up error) is displayed".



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-04

D

Communication error between the engine and controller

Communication could not linked up.

IPU and/or CTL defective

Incorrect connection between CTL and IPU.

Refer to page 6-227 "When SC670 (Engine start up error) is displayed".



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-10

D

Controller start up error

After the machine was powered on, communication between the controller and the operation panel was not established.

Controller stalled

Board installed incorrectly

Controller board defective

Operation panel connector loose, broken, or defective

Controller late

Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed".

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 620-687


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-11

D

Controller start up error

After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.

Controller stalled

Board installed incorrectly

Controller board defective

Operation panel connector loose, broken, or defective

Controller late

Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed".



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-12

D

Controller start up error

Communication with controller was interrupted after a normal startup.

Controller stalled

Board installed incorrectly

Controller board defective

Operation panel connector loose, broken, or defective

Controller late

Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed".

Service Call 620-687



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-13

D

Controller start up error

The operation panel detects that the controller is down due to other reason shown in SC672-10, SC672-11, and SC672-12.

Controller stalled

Board installed incorrectly

Controller board defective

Operation panel connector loose, broken, or defective

Controller late

Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed".



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-99

D

Controller start up error

The operation panel software ended abnormally.

Controller stalled

Board installed incorrectly

Controller board defective

Operation panel connector loose, broken, or defective

Controller late

Refer to page 6-229 "When SC672 (Controller start up error) Is Displayed".

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 620-687



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC673-10

D

Operation panel Flair communication error (Smart Operation Panel)

This SC is issued only for the machine that has the Smart Operation Panel installed.

Communication between Smart Operation Panel and main machine (this is called "Flair communication") is not sent to Smart Operation Panel.

SP setting (SP5-748-201) for Smart Operation Panel is not activated.

The CATS module (controller) did not see the response to notification of monitoring service module (operation panel).

Turn the main power OFF/ON.

Set SP5-748-201 (OpePanel Setting: Cheetah Panel Connect Setting) to "1: Connect" if the value is "0: Not connect".