HOME PAGE | < Previous | Contents | Next >

Main SP Tables - 4


2.6 MAIN SP TABLES - 4


SP Mode Tables

SP Mode Tables

SP Mode Tables

2.6.1 SP4-XXX (SCANNER)



4008

[Sub Scan Magnification Adj]

Adjusts Sub Scan Magnification by 0.1% each step.


001


-


*ENG

[-1.0 to 1.0 / 0.0 / 0.1 %/step] Picture will stretch as value increases.

Picture will shrink as value decreases.




4010

[Sub Scan Registration Adj]

Adjusts Sub Scan Registration position of book scanner by 0.1mm each step.


001


-


*ENG

[-2.0 to 2.0 / 0.0 / 0.1 mm/step] Picture will move to back edge of sub scan as value increases.

Picture will move to front edge of sub scan as value decreases.




4011

[Main Scan Reg]

Adjust Main Scan Registration position by 0.1mm each step.


001


-


*ENG

[-2.5 to 2.5 / 0.0 / 0.1 mm/step] Picture moves to right as value increases.

Picture moves to left as value decreases.



4012

[Set Scale Mask]

Main SP Tables - 4



Adjusts scanning margins for the leading and trailing edges (sub scan) and right and left edge (main scan).

Do not adjust unless the customer desires a scanner margin greater than the printer margin. These settings are adjusted to erase shadows caused by the gap between the original and the scale of the scanner unit.


001

Book:Sub LEdge

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase scale shadow of sub scan leading edge (left side or original table) when scanning with book scanner.


002

Book:Sub TEdge

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase scale shadow of sub scan trailing edge (right side or original table) when scanning with book scanner.


003

Book:Main:LEdge

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase scale shadow of main scan leading edge (rear side or original table) when scanning with book scanner.


004

Book:Main:TEdge

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase scale shadow of main scan trailing edge (front side or original table) when scanning with book scanner.


005

ADF: Leading Edge

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase scale shadow of sub scan leading edge when scanning with ADF.


007

ADF: Right

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase scale shadow of main scan leading edge when scanning with ADF.


008

ADF: left

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase scale shadow of main scan trailing edge when scanning with ADF.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




4013

[Scanner Free Run]


Scan operation amount will depend of the latest scanning size


001


Book mode :Lamp Off


ENG

[0 or 1 / 0 / 1/step]

0: OFF

1: ON

Repeats carriage reciprocating motion with lamp off.


002


Book mode :Lamp On


ENG

[0 or 1 / 0 / 1/step]

0: OFF

1: ON

Repeats carriage reciprocating motion with lamp on.



4014

[Scan]


001


HP Detection Enable


ENG

[0 or 1 / 0 / 1/step] 0:OFF, 1:ON

Runs Scanner (HP Detection Enable).

Reading size, speed is same as the most recent run(Default is FC, A3, Actual size)


002


HP Detection Disable


ENG

[0 or 1 / 0 / 1/step] 0:OFF, 1:ON

Runs Scanner (HP Detection Disable).

Reading size, speed is same as the most recent run(Default is FC, A3, Actual size)



4020

[Dust Check]


001


Dust Detect:On/Off


*ENG

[0 or 1 / 0 / 1/step]

0: OFF, 1: ON

Sets DF Dust Detection ON/OFF.

Main SP Tables - 4



002


Dust Detect:Lvl


*ENG

[0 to 8 / 4 / 1/step]

0: lowest detection level 8: highest detection level

Sets DF Dust Detect Level. Easier to Detect as Value increases.

4020

[Dust Check Lvl]


003

Dust Reject:Lvl

*ENG

[0 to 4 / 0 / 1/step]

Sets ON/OFF and switches level of Vertical stripes correction. 0=OFF, sets level to 1 from 4. Stronger correction as value increases.

4020

[DF Dust Check]


011


Dust Detect Level:Rear


*ENG

[0 or 1 / 0 / 1/step]

0: OFF, 1: ON

Sets ON/OFF DF: Rear dust detection setting.


012


Correction Level:Rear


*ENG

[0 to 8 / 4 / 1/step] 0:Lowest level 8:Highest level

Sets DF: Rear dust detection level. As the value enlarges, easier to detect.



4201

[LoCPP edge level:K]


001


600dpi 2bit edge1


*ENG

[0 to 15 / 11 / 1/step]

Value increase: Tonner adhesion amount will increase for Bk picture edge.

Toner decrease: Toner adhesion amount will decrease for Bk picture edge.

Upper limit threshold parameter for smaller edge: 600dpi 2bit

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



002


600dpi 2bit edge23


*ENG

[0 to 15 / 11 / 1/step]

Value increase: Tonner adhesion amount will increase for Bk picture edge.

Toner decrease: Toner adhesion amount will decrease for Bk picture edge

Upper limit threshold parameter for larger edge: 600dpi 2bit


003


600dpi 4bit edge1


*ENG

[0 to 15 / 11 / 1/step]

Value increase: Tonner adhesion amount will increase for Bk picture edge.

Toner decrease: Toner adhesion amount will decrease for Bk picture edge.

Upper limit threshold parameter for smaller edge: 600dpi 4bit


004


600dpi 4bit edge23


*ENG

[0 to 15 / 11 / 1/step]

Value increase: Tonner adhesion amount will increase for Bk picture edge.

Toner decrease: Toner adhesion amount will decrease for Bk picture edge.

Upper limit threshold parameter for larger edge: 600dpi 4bit


4201

[LoCPP edge off/on:K]

Off/on for Smaller/larger edge: 1200dpi 1bit


011

1200dpi 1bit edge12

*ENG

[0 or 1 / 0 / 1/step]

ON/OFF for smaller edge: 1200dpi 1bit

Select ON/OFF for low CPP edge correction with 1200dpi 1bit.


012

1200dpi 1bit edge345

*ENG

[0 or 1 / 0 / 1/step]

ON/OFF for larger edge: 1200dpi 1bit

Select ON/OFF for low CPP edge correction with 1200dpi 1bit.

Main SP Tables - 4


4301

[Operation Check APS Sensor]


001


Operation Check APS Sensor


*ENG

[0 to 255 / 0 / 1/step]

0: Not detected

1: Detected

SP for testing APS Sensor function.



4303

[Min Size for APS]


001


Min Size for APS


*ENG

[0 or 1 / 0 / 1/step] 0 : No Original

1: A5-Lengthwise

Sets display when non-standard (small size) size original is detected.


Sets display when non-standard (small size) size original is detected.

When “2:EU” is selected at SP5-131-001 and “3:8K 16K” with SP4-305-001, Decision of SP4-303-001 will be “1:16K Vertical”



4305

[8K/16K Detection]


001


-


*ENG

[0 to 3 / 0 / 1/step]

0: Normal Detection

1: A4-Sideways LT-Lengthwise

2: LT-Sideways A4-Lengthwise

3: 8K 16K

Sets assign of decision size when original size is detected.


When “0: JA” or “1: NA” is set at SP5-131-001, “3: 8K 16K series” can not be selected with SP4-305-001.



4308

[Scan Size Detection]


001


Detection ON/OFF


*ENG

[0 to 2 / 1 / 1/step]

0: OFF

1: ON

2: APS

Switch Original size detection ON/OFF.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4309

[Scan Size Detect:Setting]


001

Original Density Thresh

*ENG

[0 to 255 / 12 / 1digit/step]

Sets scan image density Thresh for Scan size detection.


002

Detection Time

*ENG

[20 to 100 / 60 / 20 msecstep]

Detection time for scan size detection.


003

Lamp ON:Delay Time

*ENG

[40 to 200 / 40 / 10 msec/step]

Adjusts lamp light timing for scan size detection.


004

LED PWM Duty

*ENG

[0 to 100 / 45 / 1/step]

Adjusts lamp light timing for scan size detection.




4310

[Scan Size Detect Value]

Checks the density of scanning data for the scan size detection.

001

S1:R

ENG


[0 to 255 / 0 / 1digit/step]

002

S1:G

ENG

003

S1:B

ENG

004

S2:R

ENG

005

S2:G

ENG

006

S2:B

ENG

007

S3:R

ENG

008

S3:G

ENG

009

S3:B

ENG

Main SP Tables - 4



4350

[Intermittent Shading : BW]


001


Switch On/Off


ENG

[0 or 1 / 1 / 1/step]

0: Every time shading 1: Interval shading

Switches On/OFF for Intermittent Shading when scanning BW (Simplex/Duplex).


002

Interval 1

ENG

[0 to 65535 / 180 / 1sec/step]

Sets Intermittent Shading interval 1(from light on to the times done in Intermittent Shading interval set with SP4-350-003) when scanning BW.


003

Interval 1 Repetitions

ENG

[1 to 60 / 1 / 1/step]

Sets Shading time within Interval1 when scanning BW.


004

Interval 2

ENG

[0 to 65535 / 180 / 1sec/step]

Sets Intermittent Shading interval 2(Intermittent Shading interval after interval1 is dome) when scanning BW.



4351

[Intermittent Shading : FC]


001


Switch On/Off


ENG

[0 or 1 / 1 / 1/step]

0: Every time shading 1: Interval shading

Selects shading operation for color scanning.


002

Interval 1

ENG

[0 to 65535 / 180 / 1sec/step]

Sets interval shading interval 1 for Color scanning (Duplex/Simplex).


003

Interval 1 Repetitions

ENG

[1 to 60 / 1 / 1/step]

Sets operating times of interval shading interval 1 for color scanning (Duplex/Simplex).


004

Interval 2

ENG

[0 to 65535 / 180 / 1sec/step]

Sets interval shading interval 2 for Color scanning (Duplex/Simplex).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4


4400

[Org Edge Mask]


001

Book:Sub:LEdge(Left)

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase original shadow of sub scan leading edge (left side or original table) when scanning with book scanner.


002

Book:Sub:TEdge(Right)

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase original shadow of sub scan trailing edge (right side or original table) when scanning with book scanner.


003

Book:Main:LEdge(Rear)

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase original shadow of main scan leading edge (rear side or original table) when scanning with book scanner.


004

Book:Main:Tedge(Front)

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase original shadow of main scan trailing edge (front side or original table) when scanning with book scanner.

4400

[Scanner Erase Margin]


005

ADF:Sub:LEdge(Left)

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase original shadow of sub scan leading edge when scanning with ADF.


007

ADF:Main:LEdge(Rear)

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase original shadow of main scan leading edge when scanning with ADF.


008

ADF:Main:TEdge(Front)

*ENG

[0.0 to 3.0 / 0.0 / 0.1 mm/step]

Sets mask area to erase original shadow of main scan trailing edge when scanning with ADF.

Main SP Tables - 4



4417

[IPU Test Pattern]


001


Test Pattern


ENG

[0 to 8 / 0 / 1/step]

0: Scanned image

1: Gradation main scan A 2: Patch 16C

3: Grid pattern A

4: Slant grid pattern B 5: Slant grid pattern C 6: Slant grid pattern D

7: Scanned+Slant Grid C 8: Scanned+Slant Grid D

Selects test pattern packaged with IPU ASIC.

Pattern is for design purpose, content of pattern will be omit,



4429

[Select Copy Data Security]


001

Copying

*ENG

[0 to 3 / 3 / 1/step]

Switches unjust copy output pattern density for copy. As the value enlarges, gets deeper.


002

Scanning

*ENG

[0 to 3 / 3 / 1/step]

Switches unjust copy output pattern density for scan. As the value enlarges, gets deeper.


003

Fax Operation

*ENG

[0 to 3 / 3 / 1/step]

Switches unjust copy output pattern density for fax. As the value enlarges, gets deeper.



4450

[Scan Image Pass Selection]


001


Black Subtraction ON/OFF


*ENG

[0 or 1 / 1 / 1/step] 0:OFF

1:ON(Normal)

Switches IPU Scanner image pass ON/OFF (black reduction).

Use to evaluate design, analyze cause of malfunction (image error).

SP Mode Tables

SP Mode Tables

SP Mode Tables


002


SH ON/OFF


*ENG

[0 or 1 / 0 / 1/step]

0: ON(Normal)

1: OFF

Switches IPU Scanner image pass ON/OFF (shading).

Use to evaluate design, analyze cause of malfunction (image error).


002


SH ON/OFF


*ENG

[0 or 1 / 0 / 1/step]

0: ON(Normal)

1: OFF

Switches IPU Scanner image pass ON/OFF (shading).

Use to evaluate design, analyze cause of malfunction (image error).


002


SH ON/OFF


*ENG

[0 or 1 / 0 / 1/step]

0: ON(Normal)

1: OFF

Switches IPU Scanner image pass ON/OFF (shading).

Use to evaluate design, analyze cause of malfunction (image error).

4460

[Digital AE]


001

Low Limit Value

*ENG

[0 to 1023 / 364 / 1/step]

Sets lower limit threshold to detect background when scanning with DF front/ Book. Considers as background when an area of input image is brighter (larger value) than threshold.


002

Background level

*ENG

[512 to 1535 / 932 / 1/step]

Sets background level to decide output value of background erase when scanning DF front / Book. As the value enlarges, gets thinner.

4460

[Digital AE]


001

Low Limit Value

*ENG

[0 to 1023 / 364 / 1/step]

Sets lower limit threshold to detect background when scanning with DF front/ Book. Considers as background when an area of input image is brighter (larger value) than threshold.


002

Background level

*ENG

[512 to 1535 / 932 / 1/step]

Sets background level to decide output value of background erase when scanning DF front / Book. As the value enlarges, gets thinner.

4460

[Digital AE]


001

Low Limit Value

*ENG

[0 to 1023 / 364 / 1/step]

Sets lower limit threshold to detect background when scanning with DF front/ Book. Considers as background when an area of input image is brighter (larger value) than threshold.


002

Background level

*ENG

[512 to 1535 / 932 / 1/step]

Sets background level to decide output value of background erase when scanning DF front / Book. As the value enlarges, gets thinner.

Main SP Tables - 4



4501

[ACC Target Den]


001

Copy:K:Text

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against letter (edge) part Black plate.


002

Copy:C:Text

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against letter (edge) part Cyan plate.


003

Copy:M:Text

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against letter (edge) part Magenta plate.


004

Copy:Y:Text

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against letter (edge) part Yellow plate.


005

Copy:K:Photo

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against photo (non edge) part Black plate.


006

Copy:C:Photo

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against photo (non edge) part Cyan plate.

Main SP Tables - 4



007

Copy:M:Photo

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against photo (non edge) part Magenta plate.


008

Copy:Y:Photo

*ENG

[0 to 10 / 5 / 1/step]

Sets target value of copy ACC against photo (non edge) part Yellow plate.



4505

[ACC Cor:Bright]


001

Master:K

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Black plate (Highlight area) depending on setting value (-128 to 127).


002

Master:C

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Cyan plate (Highlight area) depending on setting value (-128 to 127).


003

Master:M

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Magenta plate (Highlight area) depending on setting value (-128 to 127).


004

Master:Y

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Yellow plate (Highlight area) depending on setting value (-128 to 127).


005

Slave:K

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Black plate (Highlight area) depending on setting value (-128 to 127).


006

Slave:C

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Cyan plate (Highlight area) depending on setting value (-128 to 127).


007

Slave:M

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Magenta plate (Highlight area) depending on setting value (-128 to 127).

008

Slave:Y

*ENG

[-128 to 127 / 0 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Yellow plate (Highlight area) depending on setting value (-128 to 127).



4506

[ACC Cor:Dark]


001

Master:K

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Black plate (Shadow area) depending on setting value (-128 to 127).


002

Master:C

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Cyan plate (Shadow area) depending on setting value (-128 to 127).


003

Master:M

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Magenta plate (Shadow area) depending on setting value (-128 to 127).


004

Master:Y

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against letter (edge) part Yellow plate (Shadow area) depending on setting value (-128 to 127).


005

Slave:K

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Black plate (Shadow area) depending on setting value (-128 to 127).


006

Slave:C

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Cyan plate (Shadow area) depending on setting value (-128 to 127).


007

Slave:M

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Magenta plate (Shadow area) depending on setting value (-128 to 127).


008

Slave:Y

*ENG

[-128 to 127 / 0 / 1/step]

Adjusts target value (larger, thinner) of copy ACC against photo (non edge) part Yellow plate (Shadow area) depending on setting value (-128 to 127).

Main SP Tables - 4



4520

[IBACC:DetectedValue]

Latest density detecting value per IBACC pattern.

001

Latest:K_P1

*ENG


[0 to 1023 / 0 / 1/step]

002

Latest:K_P2

*ENG

003

Latest:K_P3

*ENG

004

Latest:K_P4

*ENG

005

Latest:K_P5

*ENG

006

Latest:K_P6

*ENG

021

Latest:C_P1

*ENG

022

Latest:C_P2

*ENG

023

Latest:C_P3

*ENG

024

Latest:C_P4

*ENG

025

Latest:C_P5

*ENG

026

Latest:C_P6

*ENG

041

Latest:M_P1

*ENG

042

Latest:M_P2

*ENG

043

Latest:M_P3

*ENG

044

Latest:M_P4

*ENG

045

Latest:M_P5

*ENG

046

Latest:M_P6

*ENG

061

Latest:Y_P1

*ENG

062

Latest:Y_P2

*ENG

063

Latest:Y_P3

*ENG

064

Latest:Y_P4

*ENG

065

Latest:Y_P5

*ENG

066

Latest:Y_P6

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4520

[IBACC:DetectedValue]

Last density detecting value per IBACC pattern.

101

Previous:K_P1

*ENG


[0 to 1023 / 0 / 1/step]

102

Previous:K_P2

*ENG

103

Previous:K_P3

*ENG

104

Previous:K_P4

*ENG

105

Previous:K_P5

*ENG

106

Previous:K_P6

*ENG

121

Previous:C_P1

*ENG

122

Previous:C_P2

*ENG

123

Previous:C_P3

*ENG

124

Previous:C_P4

*ENG

125

Previous:C_P5

*ENG

126

Previous:C_P6

*ENG

141

Previous:M_P1

*ENG

142

Previous:M_P2

*ENG

143

Previous:M_P3

*ENG

144

Previous:M_P4

*ENG

145

Previous:M_P5

*ENG

146

Previous:M_P6

*ENG

161

Previous:Y_P1

*ENG

162

Previous:Y_P2

*ENG

163

Previous:Y_P3

*ENG

164

Previous:Y_P4

*ENG

165

Previous:Y_P5

*ENG

166

Previous:Y_P6

*ENG

Main SP Tables - 4



4540

[Print Coverage]


001


RY Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of R (to Y) Phase.


002

RY Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding R (to Y) Phase. Larger the darker.


003

RY Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding R (to Y) Phase. Larger the darker.


004

RY Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding R (to Y) Phase. Larger the darker.


005


YR Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of Y (to R) Phase.


006

YR Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding Y (to R) Phase. Larger the darker.


007

YR Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding Y (to R) Phase. Larger the darker.


008

YR Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding Y (to R) Phase. Larger the darker.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



009


YG Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of Y (to G) Phase.


010

YG Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding Y (to G) Phase. Larger the darker.


011

YG Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding Y (to G) Phase. Larger the darker.


012

YG Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding Y (to G) Phase. Larger the darker.


013


GY Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of G (to Y) Phase.


014

GY Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding G (to Y) Phase. Larger the darker.


015

GY Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding G (to Y) Phase. Larger the darker.


016

GY Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding G (to Y) Phase. Larger the darker.

Main SP Tables - 4



017


GC Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of G (to C) Phase.


018

GC Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding G (to C) Phase. Larger the darker.


019

GC Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding G (to C) Phase. Larger the darker.


020

GC Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding G (to C) Phase. Larger the darker.


021


CG Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of C (to G) Phase.


022

CG Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding C (to G) Phase. Larger the darker.


023

CG Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding C (to G) Phase. Larger the darker.


024

CG Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding C (to G) Phase. Larger the darker.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



025


CB Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of C (to B) Phase.


026

CB Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding C (to B) Phase. Larger the darker.


027

CB Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding C (to B) Phase. Larger the darker.


028

CB Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding C (to B) Phase. Larger the darker.


029


BC Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of B (to C) Phase.


030

BC Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding B (to C) Phase. Larger the darker.


031

BC Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding B (to C) Phase. Larger the darker.


032

BC Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding B (to C) Phase. Larger the darker.

Main SP Tables - 4



033


BM Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of B (to M) Phase.


034

BM Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding B (to M) Phase. Larger the darker.


035

BM Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding B (to M) Phase. Larger the darker.


036

BM Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding B (to M) Phase. Larger the darker.


037


MB Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of M (to B) Phase.


038

MB Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding M (to B) Phase. Larger the darker.


039

MB Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding M (to B) Phase. Larger the darker.


040

MB Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding M (to B) Phase. Larger the darker.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



041


MR Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of M (to R) Phase.


042

MR Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding M (to R) Phase. Larger the darker.


043

MR Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding M (to R) Phase. Larger the darker.


044

MR Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding M (to R) Phase. Larger the darker.


045


RM Phase: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of R (to M) Phase.


046

RM Phase: R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding R (to M) Phase. Larger the darker.


047

RM Phase: G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding R (to M) Phase. Larger the darker.


048

RM Phase: B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding R (to M) Phase. Larger the darker.

Main SP Tables - 4



049


WHITE: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of highlight area.


050

WHITE:R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding highlight area. Larger the darker.


051

WHITE:G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding highlight area. Larger the darker.


052

WHITE:B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding highlight area. Larger the darker.


053


BLACK: Option


*ENG

[0 to 255 / 0 / 1/step] 0:OFF

1:ON

Sets ON/OFF (0: OFF, 1: ON) for copy output color adjust (each corresponding picture quality mode) of shadow area.


054

BLACK:R

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (C ingredient) corresponding shadow area. Larger the darker.


055

BLACK:G

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (M ingredient) corresponding shadow area. Larger the darker.


056

BLACK:B

*ENG

[-256 to 255 / 0 / 1/step]

Adjusts Value (-256 to +255) for copy output color (Y ingredient) corresponding shadow area. Larger the darker.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4550

[Scan Apli:Txt/Print]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Text/Chart mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Text/ Chart mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Text/ Chart mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Text/ Chart mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Text/ Chart mode. 0 is for OFF, Larger the value, Stronger the Erase.



4551

[Scan Apli:Txt]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Text mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Text mode. 0 is for OFF, Larger the value, the Smoother.

Main SP Tables - 4



007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Text mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Text mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Text mode. 0 is for OFF, Larger the value, Stronger the Erase.



4552

[Scan Apli:Txt Dropout]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Text (Drop Out Color) mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Text (Drop Out Color) mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Text (Drop Out Color) mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Text (Drop Out Color) mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Text (Drop Out Color) mode. 0 is for OFF, Larger the value, Stronger the Erase.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4553

[Scan Apli:Txt/Photo]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Text/Photo mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Text/Photo mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Text/Photo mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Text/Photo mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Text/Photo mode. 0 is for OFF, Larger the value, Stronger the Erase.



4554

[Scan Apli:Photo]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Photo mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Photo mode. 0 is for OFF, Larger the value, the Smoother.

Main SP Tables - 4



007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Photo mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Photo mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Photo mode. 0 is for OFF, Larger the value, Stronger the Erase.



4565

[Scan Apli:GrayScale]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: GrayScale mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: GrayScale mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: GrayScale mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: GrayScale mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: GrayScale mode. 0 is for OFF, Larger the value, Stronger the Erase.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4570

[Scan Apli:Col Txt/Photo]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Color Text/Photo mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Color Text/Photo mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Color Text/Photo mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Color Text/Photo mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Color Text/Photo mode. 0 is for OFF, Larger the value, Stronger the Erase.



4571

[Scan Apli:Col Gloss Photo]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Color Gloss Photo mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Color Gloss Photo mode. 0 is for OFF, Larger the value, the Smoother.

Main SP Tables - 4



007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Color Gloss Photo mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Color Gloss Photo mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Color Gloss Photo mode. 0 is for OFF, Larger the value, Stronger the Erase.



4572

[Scan Apli:AutoCol]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for Scan Apli: Auto Color mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for Scan Apli: Auto Color mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for Scan Apli: Auto Color mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for Scan Apli: Auto Color mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for Scan Apli: Auto Color mode. 0 is for OFF, Larger the value, Stronger the Erase.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4580

[Fax Apli:Txt/Chart]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for FAX Apli: Text/Chart mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for FAX Apli: Text/Chart mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for FAX Apli: Text/Chart mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for FAX Apli: Text/Chart mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for FAX Apli: Text/Chart mode. 0 is for OFF, Larger the value, Stronger the Erase.


010

Texture Erase: 0

*ENG

[0 to 2 / 0 / 1/step]

Sets Texture Erase for FAX Apli: Text/Chart mode. 0: Fixed Threshold, 1: Variable Threshold, 2: Variable Threshold (Threshold type used for 1 and 2 are different)



4581

[Fax Apli:Txt]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for FAX Apli: Text mode. 0 is for OFF, Larger the value, Stronger the emphasis.

Main SP Tables - 4



006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for FAX Apli: Text mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for FAX Apli: Text mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for FAX Apli: Text mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for FAX Apli: Text mode. 0 is for OFF, Larger the value, Stronger the Erase.



4582

[Fax Apli:Txt/Photo]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for FAX Apli: Text/Photo mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for FAX Apli: Text/Photo mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for FAX Apli: Text/Photo mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for FAX Apli: Text/Photo mode. 128 is for No Correction, Larger the value, Stronger the Contrast.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for FAX Apli: Text/Photo mode. 0 is for OFF, Larger the value, Stronger the Erase.


010

Texture Erase: 0

*ENG

[0 to 2 / 0 / 1/step]

Sets Texture Erase for FAX Apli: Text/Photo mode. 0: Fixed Threshold, 1: Variable Threshold, 2: Variable Threshold (Threshold type used for 1 and 2 are different)



4583

[Fax Apli:Photo]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for FAX Apli: Photo mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for FAX Apli: Photo mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for FAX Apli: Photo mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for FAX Apli: Photo mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for FAX Apli: Photo mode. 0 is for OFF, Larger the value, Stronger the Erase.

010

Texture Erase: 0

*ENG

[0 to 2 / 0 / 1/step]

Main SP Tables - 4



Sets Texture Erase for FAX Apli: Photo mode. 0: Fixed Threshold, 1: Variable Threshold, 2: Variable Threshold (Threshold type used for 1 and 2 are different)



4584

[Fax Apli:Original 1]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for FAX Apli: Special Original 1 mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

Sets Smoothing level for FAX Apli: Special Original 1 mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for FAX Apli: Special Original 1 mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for FAX Apli: Special Original 1 mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Ind Dot Erase: 0(Off) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for FAX Apli: Special Original 1 mode. 0 is for OFF, Larger the value, Stronger the Erase.



4585

[Fax Apli:Original 2]


005

MTF: 0(Off) 1-15

(Weak-Strong)


*ENG


[0 to 15 / 8 / 1/step]

Sets emphasis level for FAX Apli: Special Original 2 mode. 0 is for OFF, Larger the value, Stronger the emphasis.


006

Smoothing: 0(x1) 1-7 (Weak-Strong)


*ENG


[0 to 7 / 4 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



Sets Smoothing level for FAX Apli: Special Original 2 mode. 0 is for OFF, Larger the value, the Smoother.


007

Brightness: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Brightness level (1 to 255) for FAX Apli: Special Original 2 mode. 128 is for No Correction, Larger the value, the Brighter.


008

Contrast: 1-255

*ENG

[1 to 255 / 128 / 1/step]

Sets Contrast level (1 to 255) for FAX Apli: Special Original 2 mode. 128 is for No Correction, Larger the value, Stronger the Contrast.


009

Independent Dot Erase (0)/ 1-7 (Strong)


*ENG


[0 to 7 / 0 / 1/step]

Sets Independent Dot Erase level for FAX Apli: Special Original 2 mode. 0 is for OFF, Larger the value, Stronger the Erase.



4600

[SBU Version Display]


001

SBU ID

ENG

[0x00 to 0xFF / 0 / 1/step]

In case of SBU's ID is irregular due to SBU malfunction, or wrong part is set, sets a cause flag to SP 4-647-001 and makes SC 144-00.


002

SCAT ID

ENG

[0x00 to 0xFF / 0 / 1/step]

Displays ID of SBU (SCAT).

In case of SBU's ID is irregular due to SBU malfunction, or wrong part is set, sets a cause flag to SP 4-647-001 and makes SC 144-00.




4602

[Scanner Memory Access]

Read/Writes register of ASIC: GASBU mount to SBU. Use for design evaluation/failure analysis.


001


-


ENG

[0x000000 to 0xFFFFFF /

0x000000 / -]

002

Scanner Memory Access

ENG

[0x0 to 0x000000FF / 0x000000 / -]

003

Data Set

ENG

-

Main SP Tables - 4



4603

[Auto Adjustment Operation]

Runs SBU adjustment (light quantity adjust, SSCG correct, checking back level, adjusting white level) normally done when scanner powers on from SP.

Use for process adjust/design evaluation/error analyze.

001

HP Detection Enable

ENG

[0 or 1 / 0 / 1/step]

002

HP Detection Disable

ENG

[0 or 1 / 0 / 1/step]



4604

[FGATE Open/Close]


001



ENG

[0 or 1 / 0 / 1/step]

0: OFF

1: ON

Used for to forcedly open/close FGATE to input scanner image data when doing scanner optical adjustment during the process.

Use for process adjust/design evaluation/error analyze.



4609

[Gray Balance Set: R]


001

Book Scan

*ENG

[-384 to 255 / -100 / 1digit/step]

Displays/Saves gray balance adjustment value (RED) of scanners face side (Book).

Adjusted value during the scanner unit Warranty process is saved.


002

DF Scan

*ENG

[-384 to 255 / -100 / 1digit/step]

Displays/Saves gray balance adjustment value (RED) of scanners face side (ADF).

Adjusted value during the scanner unit Warranty process is saved.


Gray balance adjustment value of DF scan can be corrected with SP4-688-001/002: DF density adjust. (temperature difference correction of Book scan and DF face side scan)

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4610

[Gray Balance Set: G]


001

Book Scan

*ENG

[-384 to 255 / -100 / 1digit/step]

Displays/Saves gray balance adjustment value (GREEN) of scanners face side (Book).

Adjusted value during the scanner unit Warranty process is saved.


002

DF Scan

*ENG

[-384 to 255 / -100 / 1digit/step]

Displays/Saves gray balance adjustment value (GREEN) of scanners face side (ADF).

Adjusted value during the scanner unit Warranty process is saved.


Gray balance adjustment value of DF scan can be corrected with SP4-688-001/002: DF density adjust. (temperature difference correction of Book scan and DF face side scan)



4611

[Gray Balance Set: B]


001

Book Scan

*ENG

[-384 to 255 / -100 / 1digit/step]

Displays/Saves gray balance adjustment value (BLUE) of scanners face side (Book).

Adjusted value during the scanner unit Warranty process is saved.


002

DF Scan

*ENG

[-384 to 255 / -100 / 1digit/step]

Displays/Saves gray balance adjustment value (BLUE) of scanners face side (ADF).

Adjusted value during the scanner unit Warranty process is saved.


Gray balance adjustment value of DF scan can be corrected with SP4-688-001/002: DF density adjust. (temperature difference correction of Book scan and DF face side scan)

Main SP Tables - 4



4635

[SSCG Correction Set]


001


Mode Selection


*ENG

[0 to 3 / 1 / 1/step]

0: Do not noise correct SSCG.

1: Only adjust analog (initial value) 2: Only adjust digital

3: Adjust both analog/digital

Selects SSCG noise correction mode.

Use when setting SSCG adjust OFF as a temporally proceed when SSCG does not work correctly due to an unexpected malfunction.

Temporally use if by changing settings improves wide stripes, side stripes caused by scanner when SSCG correction does not work correctly.



4637

[SSCG Correction Value (Ana.)]


001

Latest:RE

ENG

[-31 to 31 / 0 / 1digit/step]

Displays SSCG analog correction value (F Side/RED/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


002

Latest:RO

ENG

[-31 to 31 / 0 / 1digit/step]

Displays SSCG analog correction value (F Side/RED/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


003

Latest:GE

ENG

[-31 to 31 / 0 / 1digit/step]

Displays SSCG analog correction value (F Side/GREEN/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


004

Latest:GO

ENG

[-31 to 31 / 0 / 1digit/step]

Displays SSCG analog correction value (F Side/GREEN/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

005

Latest:BE

ENG

[-31 to 31 / 0 / 1digit/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables


Displays SSCG analog correction value (F Side/BLUE/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


006

Latest:BO

ENG

[-31 to 31 / 0 / 1digit/step]

Displays SSCG analog correction value (F Side/BLUE/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


Displays SSCG analog correction value (F Side/BLUE/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


006

Latest:BO

ENG

[-31 to 31 / 0 / 1digit/step]

Displays SSCG analog correction value (F Side/BLUE/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


Displays SSCG analog correction value (F Side/BLUE/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


006

Latest:BO

ENG

[-31 to 31 / 0 / 1digit/step]

Displays SSCG analog correction value (F Side/BLUE/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

4638

[SSCG Correction Value (Dig.)]


001

Latest:RE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/RED/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


002

Latest:RO

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/RED/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


003

Latest:GE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/GREEN/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


004

Latest:GO

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/GREEN/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


005

Latest:BE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/BLUE/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

4638

[SSCG Correction Value (Dig.)]


001

Latest:RE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/RED/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


002

Latest:RO

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/RED/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


003

Latest:GE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/GREEN/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


004

Latest:GO

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/GREEN/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


005

Latest:BE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/BLUE/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

4638

[SSCG Correction Value (Dig.)]


001

Latest:RE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/RED/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


002

Latest:RO

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/RED/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


003

Latest:GE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/GREEN/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


004

Latest:GO

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/GREEN/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


005

Latest:BE

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/BLUE/EVEN pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

Main SP Tables - 4

Main SP Tables - 4




006

Latest:BO

*ENG

[-255 to 255 / 0 / 1digit/step]

Displays SSCG Digital correction value (F Side/BLUE/ODD pixel). Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).



4639

[SSCG Noise Cancel (Analog)]


001

Factory Setting:RE

*ENG

[-31 to 31 / 0 / 1digit/step]

Display/Saves Factory SSCG Analog correction value (F Side/RED/EVEN pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


002

Factory Setting:RO

*ENG

[-31 to 31 / 0 / 1digit/step]

Display/Saves Factory SSCG Analog correction value (F Side/RED/ODD pixel). Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


003

Factory Setting:GE

*ENG

[-31 to 31 / 0 / 1digit/step]

Display/Saves Factory SSCG Analog correction value (F Side/GREEN/EVEN pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


004

Factory Setting:GO

*ENG

[-31 to 31 / 0 / 1digit/step]

Display/Saves Factory SSCG Analog correction value (F Side/GREEN/ODD pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




005

Factory Setting:BE

*ENG

[-31 to 31 / 0 / 1digit/step]

Display/Saves Factory SSCG Analog correction value (F Side/BLUE/EVEN pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


006

Factory Setting:BO

*ENG

[-31 to 31 / 0 / 1digit/step]

Display/Saves Factory SSCG Analog correction value (F Side/BLUE/ODD pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.



4640

[SSCG Correction Value (Dig.)]


001

Factory Setting:RE

ENG

[-255 to 255 / 0 / 1digit/step]

Display/Saves Factory SSCG Digital correction value (F Side/RED/EVEN pixel). Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


002

Factory Setting:RO

ENG

[-255 to 255 / 0 / 1digit/step]

Display/Saves Factory SSCG Digital correction value (F Side/RED/ODD pixel). Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


003

Factory Setting:GE

ENG

[-255 to 255 / 0 / 1digit/step]

Display/Saves Factory SSCG Digital correction value (F Side/GREEN/EVEN pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.

Main SP Tables - 4




004

Factory Setting:GO

ENG

[-255 to 255 / 0 / 1digit/step]

Display/Saves Factory SSCG Digital correction value (F Side/GREEN/ODD pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


005

Factory Setting:BE

ENG

[-255 to 255 / 0 / 1digit/step]

Display/Saves Factory SSCG Digital correction value (F Side/BLUE/EVEN pixel).

Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.


006

Factory Setting:BO

ENG

[-255 to 255 / 0 / 1digit/step]

Display/Saves Factory SSCG Digital correction value (F Side/BLUE/ODD pixel). Adjusted SSCG correction Value during the main unit warranty process is saved.

Use for analyzing malfunction, comparing factory / current value.



4641

[SSCG Noise Amplitude]


001

RE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays SSCG Nose Amplitude (F Side/RED/EVEN pixel) when adjusting SSCG.

Correction value will be decided depending on detected Noise Amplitude when adjusting.

Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




002

RO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays SSCG Nose Amplitude (F Side/RED/ODD pixel) when adjusting SSCG.

Correction value will be decided depending on detected Noise Amplitude when adjusting.

Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


003

GE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays SSCG Nose Amplitude (F Side/GREEN/EVEN pixel) when adjusting SSCG.

Correction value will be decided depending on detected Noise Amplitude when adjusting.

Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


004

GO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays SSCG Nose Amplitude (F Side/GREEN/ODD pixel) when adjusting SSCG.

Correction value will be decided depending on detected Noise Amplitude when adjusting.

Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).


005

BE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays SSCG Nose Amplitude (F Side/BLUE/EVEN pixel) when adjusting SSCG.

Correction value will be decided depending on detected Noise Amplitude when adjusting.

Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

Main SP Tables - 4




006

BO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays SSCG Nose Amplitude (F Side/BLUE/ODD pixel) when adjusting SSCG.

Correction value will be decided depending on detected Noise Amplitude when adjusting.

Adjustment will be done when scanner turns on.

Use for design evaluation, analyzing malfunction (abnormal images).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




4646

[Scan Adjust Error]

Displays error value of scanning adjustment.


001


White level


ENG

[0 to 65535 / 0 / 1/step] Bit15:Unused

Bit14: Unused

Bit13:White level abnormal (F side/RED/EVEN pixel)

Bit12: White level abnormal (F side

/RED/ODD pixel)

Bit11: White level abnormal (F side

/GREEN/EVEN pixel)

Bit10: White level abnormal (F side

/GREEN/ODD pixel)

Bit9: White level abnormal (F side

/BLUE/EVEN pixel)

Bit8:White level abnormal (F side

/BLUE/ODD pixel) Bit7: Unused

Bit6: Unused

Bit5:gain abnormal (F side

/RED/EVEN pixel)

Bit4: gain abnormal (F side

/RED/ODD pixel)

Bit3: gain abnormal (F side

/GREEN/EVEN pixel)

Bit2: gain abnormal (F side

/GREEN/ODD pixel)

Bit1: gain abnormal (F side

/BLUE/EVEN pixel)

Bit0: gain abnormal (F side

/BLUE/ODD pixel)

Main SP Tables - 4



Shows cause of error when an error occurs during the white level adjustment when scanner turns on.

When an error, SC142-00(F side/white level adjustment error)will be given.[format] binary

Scan adjust error (F side/White level) flag= (b15,b14,b13,b12,b11,b10,b9,b8,b7,b6,b5,b4,b3,b2,b1,b0)


002


Black level


ENG

[0 to 65535 / 0 / 1/step] Bit7: Unused

Bit6: Unused

Bit5: Black level abnormal (F side/RED/EVEN Pixel)

Bit4: Black level abnormal (F side

/RED/ODD Pixel)

Bit3: Black level abnormal (F side

/GREEN/EVEN Pixel)

Bit2: Black level abnormal (F side

/GREEN/ODD Pixel)

Bit1: Black level abnormal (F side

/BLUE/EVEN Pixel)

Bit0: Black level abnormal (F side

/BLUE/ODD Pixel)

Shows cause of error when an error occurs With the Black level check when scanner turns on.

When an error, SC141-00(F side/Black level adjustment error) will be given. [format] binary

Scan adjust error (F side/Black level) flag=(b7,b6,b5,b4,b3,b2,b1,b0)

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



003


SSCG Correction


ENG

[0 to 65535 / 0 / 1/step] Bit7: Unused

Bit6: Unused

Bit5: SSCG correction error (Fside/RED/EVEN Pixel) Bit4: SSCG correction error (Fside/RED/ODD Pixel) Bit3: SSCG correction error (Fside/GREEN/EVEN Pixel) Bit2: SSCG correction error (Fside/GREEN/ODD Pixel) Bit1: SSCG correction error (Fside/BLUE/EVEN Pixel) Bit0: SSCG correction error (Fside/BLUE/ODD Pixel)

Shows cause of error when an error occurs With the SSCG Noise correction when scanner turns on.

When an error, Correction turns off. [format] binary

Scan adjust error (F side/SSCG correction) flag= (b7,b6,b5,b4,b3,b2,b1,b0)

Main SP Tables - 4




4647

[Scanner Hard Error]

Displays result of SBU connection check.


001


Power-ON


ENG

[0 to 65535 / 0 / 1/step] Bit15: Unused

Bit14:SBU hardware error (Power ON/un-reset error)

Bit13:SBU hardware error (Serial communication error: F side) Bit12:SBU hardware error (Reset error: F side)

Bit11: Unused Bit10: Unused

Bit9:SBU hardware error (Version error)

Bit8: Unused Bit7: Unused Bit6: Unused

Bit5:SBU hardware error (Serial communication error: L side) Bit4:SBU hardware error (Reset error:Lside)

Bit3: Unused Bit2: Unused Bit1: Unused

Shows cause of error when an error occurs with the SBU connection detect when Scanner turns on..

When an error, SC144-00 (SBU Communication error) will be given. [format] binary

Scan adjust error (SSCG correction) flag= (b15,b14,b13,b12,b11,b10,b9,b8,b7,b6,b5,b4,b3,b2,b1,b0)

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4651

[Black Level Adj. Value (Ana.)]


001

Latest: RE Color

ENG

[0 to 127 / 0 / 1digit/step]

Displays black level analog adjustment value (RED/EVEN pixel).

Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: RO Color

ENG

[0 to 127 / 0 / 1digit/step]

Displays black level analog adjustment value (RED/ODD pixel).

Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4652

[Black Level Adj. Value (Ana.)]


001

Latest: GE Color

ENG

[0 to 127 / 0 / 1digit/step]

Displays black level analog adjustment value (GREEN/EVEN pixel). Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU.

Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: GO Color

ENG

[0 to 127 / 0 / 1digit/step]

Displays black level analog adjustment value (GREEN/ODD pixel). Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU.

Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4


4653

[Black Level Adj. Value (Ana.)]


001

Latest: BE Color

ENG

[0 to 127 / 0 / 1digit/step]

Displays black level analog adjustment value (BLUE/EVEN pixel). Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU.

Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: BO Color

ENG

[0 to 127 / 0 / 1digit/step]

Displays black level analog adjustment value (BLUE/ODD pixel).

Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4654

[Black Level Adj. Value (Dig.)]


001

Latest: RE Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays black level digital adjustment value (RED/EVEN pixel).

Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: RO Color

*ENG

0 to 16383 / 0 / 1digit/step]

Displays black level digital adjustment value (RED/ODD pixel).

Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4655

[Black Level Adj. Value (Dig.)]


001

Latest: GE Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays black level digital adjustment value (GREEN/EVEN pixel). Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: GO Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays black level digital adjustment value (GREEN/ODD pixel). Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU.

Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4656

[Black Level Adj. Value (Dig.)]


001

Latest: BE Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays black level digital adjustment value (BLUE/EVEN pixel).

Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: BO Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays black level digital adjustment value (BLUE/ODD pixel).

Black level adjust is regularly done hardwarely by ASIC (SCAT) of SBU. Adjusted value will be given from checking the black level when scanner powers ON.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4


4658

[Analog Gain Adjust]


001

Latest: R Color

*ENG

[0 to 14 / 0 / 1digit/step]

Displays analog gain adjustment value (RED pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4659

[Analog Gain Adjust]


001

Latest: G Color

*ENG

[0 to 14 / 0 / 1digit/step]

Displays analog gain adjustment value (GREEN pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4660

[Analog Gain Adjust]


001

Latest: B Color

*ENG

[0 to 14 / 0 / 1digit/step]

Displays analog gain adjustment value (BLUE pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4661

[Digital Gain Adjust]


001

Latest: RE Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays digital gain adjustment value (RED/EVEN pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: RO Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays digital gain adjustment value (RED/ODD pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4662

[Digital Gain Adjust]


001

Latest: GE Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays digital gain adjustment value (GREEN/EVEN pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4




002

Latest: GO Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays digital gain adjustment value (GREEN/ODD pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4663

[Digital Gain Adjust]


001

Latest: BE Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays digital gain adjustment value (BLUE/EVEN pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: BO Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays digital gain adjustment value (BLUE/ODD pixel).

White level adjust is done when scanner powers ON to keep the dynamic range of image signal.

Image signal will be amplified or attenuated with white level adjust, therefore gain adjust will be done by ASIC (SCAT) of SBU hardwarely, and adjusted value will be given.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4670

[Black Level Adj. Value (Ana.)]


001

Factory Setting: RE Color

*ENG

[0 to 127 / 0 / 1digit/step]

Displays/Saves factory default black level analog adjust value (RED/EVEN pixel).

Factory default black level analog adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: RO Color

*ENG

[0 to 127 / 0 / 1digit/step]

Displays/Saves factory default black level analog adjust value (RED/ODD pixel). Factory default black level analog adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4671

[Black Level Adj. Value (Ana.)]


001

Factory Setting: GE Color

*ENG

[0 to 127 / 0 / 1digit/step]

Displays/Saves factory default black level analog adjust value (GREEN/EVEN pixel).

Factory default black level analog adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: GO Color

*ENG

[0 to 127 / 0 / 1digit/step]

Displays/Saves factory default black level analog adjust value (GREEN/ODD pixel).

Factory default black level analog adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4



4672

[Black Level Adj. Value (Ana.)]


001

Factory Setting: BE Color

*ENG

[0 to 127 / 0 / 1digit/step]

Displays/Saves factory default black level analog adjust value (BLUE/EVEN pixel).

Factory default black level analog adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: BO Color

*ENG

[0 to 127 / 0 / 1digit/step]

Displays/Saves factory default black level analog adjust value (BLUE/ODD pixel).

Factory default black level analog adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4673

[Black Level Adj. Value (Dig.)]


001

Factory Setting: RE Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays/Saves factory default black level digital adjust value (RED/EVEN pixel).

Factory default black level digital adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: RO Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays/Saves factory default black level digital adjust value (RED/ODD pixel). Factory default black level digital adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4674

[Black Level Adj. Value (Dig.)]


001

Factory Setting: GE Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays/Saves factory default black level digital adjust value (GREEN/EVEN pixel).

Factory default black level digital adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: GO Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays/Saves factory default black level digital adjust value (GREEN/ODD pixel).

Factory default black level digital adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4675

[Black Level Adj. Value (Dig.)]


001

Factory Setting: BE Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays/Saves factory default black level digital adjust value (BLUE/EVEN pixel).

Factory default black level digital adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: BO Color

*ENG

[0 to 16383 / 0 / 1digit/step]

Displays/Saves factory default black level digital adjust value (BLUE/ODD pixel).

Factory default black level digital adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4


4677

[Analog Gain Adjust]


001

Factory Setting: R Color

*ENG

[0 to 14 / 0 / 1digit/step]

Displays/Saves factory default analog gain adjust value (RED pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4678

[Analog Gain Adjust]


001

Factory Setting: G Color

*ENG

[0 to 14 / 0 / 1digit/step]

Displays/Saves factory default analog gain adjust value (GREEN pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4679

[Analog Gain Adjust]


001

Factory Setting: B Color

*ENG

[0 to 14 / 0 / 1digit/step]

Displays/Saves factory default analog gain adjust value (BLUE pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4680

[Digital Gain Adjust]


001

Factory Setting: RE Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves factory default digital gain adjust value (RED/EVEN pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: RO Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves factory default digital gain adjust value (RED/ODD pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4681

[Digital Gain Adjust]


001

Factory Setting: GE Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves factory default digital gain adjust value (GREEN/EVEN pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: GO Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves factory default digital gain adjust value (GREEN/ODD pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4



4682

[Digital Gain Adjust]


001

Factory Setting: BE Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves factory default digital gain adjust value (BLUE/EVEN pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: BO Color

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves factory default digital gain adjust value (BLUE/ODD pixel). Factory default analog gain adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4688

[DF Density Adjustment]


001


ARDF


*ENG

[80 to 120 / 102 / 1 %/step] Value increase: ADF density deeper.

Value decrease: ADF density thinner.

For Oversetters only. Adjusts density difference between Book and ADF.

4688

[Scan Image Density Adjustment]


002

1-pass DF

*ENG

[80 to 120 / 103 / 1 %/step]

For Single-Pass simultaneous duplex models only. Adjusts density difference between Book and ADF.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4690

[White Level Peak Read]


001

RE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (RED/EVEN pixel).

White level adjust is done by scanning the white reference plate when scanner powers ON to keep the dynamic range of image signal.

Scanning level of white reference plate from white level adjusting is given. When white level peak scanning value is an error (adjustment not finishing correctly) SC142-00 is given.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

RO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (RED/ODD pixel).

White level adjust is done by scanning the white reference plate when scanner powers ON to keep the dynamic range of image signal.

Scanning level of white reference plate from white level adjusting is given. When white level peak scanning value is an error (adjustment not finishing correctly) SC142-00 is given.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4691

[White Level Peak Read]


001

GE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (GREEN/EVEN pixel).

White level adjust is done by scanning the white reference plate when scanner powers ON to keep the dynamic range of image signal.

Scanning level of white reference plate from white level adjusting is given. When white level peak scanning value is an error (adjustment not finishing correctly) SC142-00 is given.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4



002

GO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (GREEN/ODD pixel).

White level adjust is done by scanning the white reference plate when scanner powers ON to keep the dynamic range of image signal.

Scanning level of white reference plate from white level adjusting is given. When white level peak scanning value is an error (adjustment not finishing correctly) SC142-00 is given.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4692

[White Level Peak Read]


001

BE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (BLUE/EVEN pixel).

White level adjust is done by scanning the white reference plate when scanner powers ON to keep the dynamic range of image signal.

Scanning level of white reference plate from white level adjusting is given. When white level peak scanning value is an error (adjustment not finishing correctly) SC142-00 is given.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

BO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (BLUE/ODD pixel).

White level adjust is done by scanning the white reference plate when scanner powers ON to keep the dynamic range of image signal.

Scanning level of white reference plate from white level adjusting is given. When white level peak scanning value is an error (adjustment not finishing correctly) SC142-00 is given.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



4693

[Black Level Peak Read]


001

RE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays black level scanning value (RED/EVEN pixel).

Black level check is done when scanner powers ON, then offset level of image signal is checked and that value will be given.

Check whether the offset adjustment of SBU (SCAT) is working correctly. Gives SC141-00 if the black level scanning value is an error.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

RO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays black level scanning value (RED/ODD pixel).

Black level check is done when scanner powers ON, then offset level of image signal is checked and that value will be given.

Check whether the offset adjustment of SBU (SCAT) is working correctly. Gives SC141-00 if the black level scanning value is an error.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).




4694

[Black Level Peak Read]

-


001

GE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays black level scanning value (GREEN/EVEN pixel).

Black level check is done when scanner powers ON, then offset level of image signal is checked and that value will be given.

Check whether the offset adjustment of SBU (SCAT) is working correctly. Gives SC141-00 if the black level scanning value is an error.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4




002

GO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays black level scanning value (GREEN/EVEN pixel).

Black level check is done when scanner powers ON, then offset level of image signal is checked and that value will be given.

Check whether the offset adjustment of SBU (SCAT) is working correctly. Gives SC141-00 if the black level scanning value is an error.

Cause of error will be displayed on SP4-646-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).




4695

[Black Level Peak Read]

-


001

BE

ENG

[0 to 1023 / 0 / 1digit/step]

Displays black level scanning value (BLUE/EVEN pixel).

Black level check is done when scanner powers ON, then offset level of image signal is checked and that value will be given.

Check whether the offset adjustment of SBU (SCAT) is working correctly. Gives SC141-00 if the black level scanning value is an error.

Cause of error will be displayed on SP4-646-002.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

BO

ENG

[0 to 1023 / 0 / 1digit/step]

Displays black level scanning value (BLUE/ODD pixel).

Black level check is done when scanner powers ON, then offset level of image signal is checked and that value will be given.

Check whether the offset adjustment of SBU (SCAT) is working correctly. Gives SC141-00 if the black level scanning value is an error.

Cause of error will be displayed on SP4-646-002.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables


4698

[Factory Setting Input]

-

001

On/Off

*ENG

[0 to 1 / 0 / 1/step]


4698

[Factory Setting Input]

-

001

On/Off

*ENG

[0 to 1 / 0 / 1/step]


4698

[Factory Setting Input]

-

001

On/Off

*ENG

[0 to 1 / 0 / 1/step]


4795

[CIS Black Level Data: B]

-

Displays black level; data of CIS.

When DF powers ON, black level of CIS is checked, then detect the black level per chip and display scanning level.

Cause of error will be displayed on SP4-745-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

001

Chip1

ENG

[0 to 255 / 0 / 1digit/step]

002

Chip2

ENG

[0 to 255 / 0 / 1digit/step]

003

Chip3

ENG

[0 to 255 / 0 / 1digit/step]

004

Chip4

ENG

[0 to 255 / 0 / 1digit/step]

005

Chip5

ENG

[0 to 255 / 0 / 1digit/step]

006

Chip6

ENG

[0 to 255 / 0 / 1digit/step]

007

Chip7

ENG

[0 to 255 / 0 / 1digit/step]

008

Chip8

ENG

[0 to 255 / 0 / 1digit/step]

009

Chip9

ENG

[0 to 255 / 0 / 1digit/step]

010

Chip10

ENG

[0 to 255 / 0 / 1digit/step]

011

Chip11

ENG

[0 to 255 / 0 / 1digit/step]

012

Chip12

ENG

[0 to 255 / 0 / 1digit/step]

013

Chip13

ENG

[0 to 255 / 0 / 1digit/step]

014

Chip14

ENG

[0 to 255 / 0 / 1digit/step]

015

Chip15

ENG

[0 to 255 / 0 / 1digit/step]


4795

[CIS Black Level Data: B]

-

Displays black level; data of CIS.

When DF powers ON, black level of CIS is checked, then detect the black level per chip and display scanning level.

Cause of error will be displayed on SP4-745-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

001

Chip1

ENG

[0 to 255 / 0 / 1digit/step]

002

Chip2

ENG

[0 to 255 / 0 / 1digit/step]

003

Chip3

ENG

[0 to 255 / 0 / 1digit/step]

004

Chip4

ENG

[0 to 255 / 0 / 1digit/step]

005

Chip5

ENG

[0 to 255 / 0 / 1digit/step]

006

Chip6

ENG

[0 to 255 / 0 / 1digit/step]

007

Chip7

ENG

[0 to 255 / 0 / 1digit/step]

008

Chip8

ENG

[0 to 255 / 0 / 1digit/step]

009

Chip9

ENG

[0 to 255 / 0 / 1digit/step]

010

Chip10

ENG

[0 to 255 / 0 / 1digit/step]

011

Chip11

ENG

[0 to 255 / 0 / 1digit/step]

012

Chip12

ENG

[0 to 255 / 0 / 1digit/step]

013

Chip13

ENG

[0 to 255 / 0 / 1digit/step]

014

Chip14

ENG

[0 to 255 / 0 / 1digit/step]

015

Chip15

ENG

[0 to 255 / 0 / 1digit/step]


4795

[CIS Black Level Data: B]

-

Displays black level; data of CIS.

When DF powers ON, black level of CIS is checked, then detect the black level per chip and display scanning level.

Cause of error will be displayed on SP4-745-001.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

001

Chip1

ENG

[0 to 255 / 0 / 1digit/step]

002

Chip2

ENG

[0 to 255 / 0 / 1digit/step]

003

Chip3

ENG

[0 to 255 / 0 / 1digit/step]

004

Chip4

ENG

[0 to 255 / 0 / 1digit/step]

005

Chip5

ENG

[0 to 255 / 0 / 1digit/step]

006

Chip6

ENG

[0 to 255 / 0 / 1digit/step]

007

Chip7

ENG

[0 to 255 / 0 / 1digit/step]

008

Chip8

ENG

[0 to 255 / 0 / 1digit/step]

009

Chip9

ENG

[0 to 255 / 0 / 1digit/step]

010

Chip10

ENG

[0 to 255 / 0 / 1digit/step]

011

Chip11

ENG

[0 to 255 / 0 / 1digit/step]

012

Chip12

ENG

[0 to 255 / 0 / 1digit/step]

013

Chip13

ENG

[0 to 255 / 0 / 1digit/step]

014

Chip14

ENG

[0 to 255 / 0 / 1digit/step]

015

Chip15

ENG

[0 to 255 / 0 / 1digit/step]

Main SP Tables - 4

Main SP Tables - 4


016

Chip16

ENG

[0 to 255 / 0 / 1digit/step]

017

Chip17

ENG

[0 to 255 / 0 / 1digit/step]

018

Chip18

ENG

[0 to 255 / 0 / 1digit/step]

019

Chip19

ENG

[0 to 255 / 0 / 1digit/step]

020

Chip20

ENG

[0 to 255 / 0 / 1digit/step]

021

Chip21

ENG

[0 to 255 / 0 / 1digit/step]

022

Chip22

ENG

[0 to 255 / 0 / 1digit/step]

023

Chip23

ENG

[0 to 255 / 0 / 1digit/step]

024

Chip24

ENG

[0 to 255 / 0 / 1digit/step]




4796

[Low Density Color Correction]

-


001


Front Side


*ENG

[0 to 3 / 0 / 1/step]

0: OFF

1: WEAK

2: MEDIUM

3: STRONG

Corrects low chroman area of front side.

With Single-Pass duplex models, coloring might change between the front side and the rear side of the gray half tone area, due to scanning system difference. if user points out this difference, by changing this setting, difference can be reduced.

Adjusts intensity of correction depending on coloring difference.

For a side effect, low chroman area's reproducibility will spoil as stronger the intensity gets.


002


Rear Side


*ENG

[0 to 3 / 0 / 1/step]

0: OFF

1: WEAK

2: MEDIUM

3: STRONG

SP Mode Tables

SP Mode Tables

SP Mode Tables


Corrects low chroman area of rear side.

With Single-Pass duplex models, coloring might change between the front side and the rear side of the gray half tone area, due to scanning system difference. if user points out this difference, by changing this setting, difference can be reduced.

Adjusts intensity of correction depending on coloring difference.

For a side effect, low chroman area's reproducibility will spoil as stronger the intensity gets.


Corrects low chroman area of rear side.

With Single-Pass duplex models, coloring might change between the front side and the rear side of the gray half tone area, due to scanning system difference. if user points out this difference, by changing this setting, difference can be reduced.

Adjusts intensity of correction depending on coloring difference.

For a side effect, low chroman area's reproducibility will spoil as stronger the intensity gets.


Corrects low chroman area of rear side.

With Single-Pass duplex models, coloring might change between the front side and the rear side of the gray half tone area, due to scanning system difference. if user points out this difference, by changing this setting, difference can be reduced.

Adjusts intensity of correction depending on coloring difference.

For a side effect, low chroman area's reproducibility will spoil as stronger the intensity gets.

4797

[Rear Side: Digital AE]


001

Low Limit Setting

*ENG

[0 to 1023 / 364 / 1/step]

Sets lower limit threshold to detect background when scanning with DF rear. Considers as background when an area of input image is brighter (larger value) than threshold.


002

Background Erase Level

*ENG

[512 to 1535 / 932 / 1/step]

Sets background level to decide output value of background erase when scanning with DF rear. As the value enlarges, gets thinner.

4797

[Rear Side: Digital AE]


001

Low Limit Setting

*ENG

[0 to 1023 / 364 / 1/step]

Sets lower limit threshold to detect background when scanning with DF rear. Considers as background when an area of input image is brighter (larger value) than threshold.


002

Background Erase Level

*ENG

[512 to 1535 / 932 / 1/step]

Sets background level to decide output value of background erase when scanning with DF rear. As the value enlarges, gets thinner.

4797

[Rear Side: Digital AE]


001

Low Limit Setting

*ENG

[0 to 1023 / 364 / 1/step]

Sets lower limit threshold to detect background when scanning with DF rear. Considers as background when an area of input image is brighter (larger value) than threshold.


002

Background Erase Level

*ENG

[512 to 1535 / 932 / 1/step]

Sets background level to decide output value of background erase when scanning with DF rear. As the value enlarges, gets thinner.

Main SP Tables - 4


4798

[CIS LED Duty]


001

-

*ENG

[0 to 65535 / 0 / 1/step]

Displays/Saves LED lighting Duty of CIS.

Value set with the shipping test of CIS is saved. Normally do not change setting.

Main SP Tables - 4



4799

[CIS TEST Pattern]


001


select


ENG

[0 to 5 / 0 / 1/step]

Sets CIS test pattern output. 0: Scanned Image

1: Fixed Value Pattern

2: EO Fixed Value Pattern 3: Main Scan Gradation 4: Sub Scan Gradation

5: Grid Pattern

To print the test pattern selected with this SP, after setting SP, press the interrupt key, and set paper size, scale, image processing conditions etc... from the panel as like a regular copy job, then set original and press copy button.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Even Output Level Setting

ENG

[0 to 4095 / 0 / 1digit/step]

Sets test pattern fixed value output level (Even) of CIS.

Fixed value will be displayed / set when SP4-799-001-1: full side fixed value, or SP4-799-001-2: Fixed value per EO is selected.


003

Odd Output Level Setting

ENG

[0 to 4095 / 0 / 1digit/step]

Sets test pattern fixed value output level (ODD) of CIS.

Fixed value will be displayed / set when SP4-799-001-1: full side fixed value, or SP4-799-001-2: Fixed value per EO is selected.



4802

[Scanner Free run]


001

DF mode :Lamp Off

ENG

[0 or 1 / 0 / 1/step]

Repeat DF shading with lamp off.


002

DF mode :Lamp On

ENG

[0 or 1 / 0 / 1/step]

Repeat DF shading with lamp on.

SP Mode Tables

SP Mode Tables

SP Mode Tables

4803

[Home Position Adj Value]


001

-

ENG

[-2 to 2 / 0 / 0.1mm/step]

Run Home position operation (Homing).

4803

[Home Position Adj Value]


001

-

ENG

[-2 to 2 / 0 / 0.1mm/step]

Run Home position operation (Homing).

4803

[Home Position Adj Value]


001

-

ENG

[-2 to 2 / 0 / 0.1mm/step]

Run Home position operation (Homing).

4804

[Home Position Operation]


001

-

ENG

[0 or 1 / 0 / 1/step]

Run Home position operation (Homing).

4804

[Home Position Operation]


001

-

ENG

[0 or 1 / 0 / 1/step]

Run Home position operation (Homing).

4804

[Home Position Operation]


001

-

ENG

[0 or 1 / 0 / 1/step]

Run Home position operation (Homing).

Main SP Tables - 4


4806

[Scan Carriage Retract Op]


001

-

ENG

[0 or 1 / 0 / 1/step]

Run Carriage retract operation.



4807

[SBU Off Mode]


001


On/Off


ENG

[0 or 1 / 1 / 0] 0:OFF

1:ON(default)

Switch ON/OFF for stopping CCD drive clock of SBU when scanner is standby. Use for process adjustment/design evaluation.

Main SP Tables - 4



4813

[ALC Selection]


001


FC


*ENG

[0 or 1 / 1 / 1/step] 0:OFF

1:ON(default)

Sets ON/OFF variable correction for scanning level of original when continuously scanning multiple originals using ADF.

For increasing productivity of ADF, creating correction data is done at a certain (3min) interval.

If shade correcting data is not updated, original scanning level will change affected by the light source brightness changing, therefore, variable will be corrected by scanning the guide plate (white) of ADF from between originals. This SP setting (enable/disable) will apply to color scan.

In an occasion of an unexpected malfunction and level correcting does not work, or background density disorderly changes among multiple scanned originals, and by changing setting these will improve; then temporarily set correction OFF.

By setting interval shading OFF with SP4-351-001, even when ALC is set to OFF, shading will be done each time, and will prevent density change when having level correction OFF.

But in this case, shading data is created (moving carriage) with original interval of ADF scanning, therefore Productivity will drop

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




002


BW


*ENG

[0 or 1 / 1 / 1/step] 0:OFF

1:ON(default)

Sets ON/OFF variable correction for scanning level of original when continuously scanning multiple originals using ADF.

For increasing productivity of ADF, creating correction data is done at a certain (3min) interval.

If shade correcting data is not updated, original scanning level will change affected by the light source brightness changing, therefore , variable will be corrected by scanning the guide plate (white) of ADF from between originals. This SP setting (enable/disable) will apply to B&W scan.

In an occasion of an unexpected malfunction and level correcting does not work, or background density disorderly changes among multiple scanned originals, and by changing setting these will improve; then temporarily set correction OFF.

By setting interval shading OFF with SP4-351-001, even when ALC is set to OFF, shading will be done each time, and will prevent density change when having level correction OFF.

But in this case, shading data is created (moving carriage) with original interval of ADF scanning, therefore Productivity will drop



4850

[PMW]


001

Latest

*ENG

[0 to 8191 / 0 / 1digit/step]

Displays LED lighting Duty (PWM) adjustment value of LED light quantity adjust.

When output of CCD is overflowed from the amount of light, Reduces light quantity by adjusting LED light source lighting duty when scanner powers ON. Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4




002

Factory Setting

*ENG

[0 to 8191 / 0 / 1digit/step]

Displays LED lighting Duty (PWM) adjustment value of factory default LED light quantity adjust.

Factory default LED lighting Duty (PWM) adjustment value is saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4851

[LED White Level Peak Read]


001

Latest: RE

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (RED/EVEN pixel) of LED light quantity adjustment.

Displays scanning levels of White reference plate when scanner powers on and LED light source lighting duty (PWM) is adjusted.

SC102-00 is given when LED light quantity does not complete.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Latest: RO

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (RED/ODD pixel) of LED light quantity adjustment.

Displays scanning levels of White reference plate when scanner powers on and LED light source lighting duty (PWM) is adjusted.

SC102-00 is given when LED light quantity does not complete.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


003

Latest: GE

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (GREEN/EVEN pixel) of LED light quantity adjustment.

Displays scanning levels of White reference plate when scanner powers on and LED light source lighting duty (PWM) is adjusted.

SC102-00 is given when LED light quantity does not complete.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



004

Latest: GO

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (GREEN/ODD pixel) of LED light quantity adjustment.

Displays scanning levels of White reference plate when scanner powers on and LED light source lighting duty (PWM) is adjusted.

SC102-00 is given when LED light quantity does not complete.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


005

Latest: BE

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (BLUE/EVEN pixel) of LED light quantity adjustment.

Displays scanning levels of White reference plate when scanner powers on and LED light source lighting duty (PWM) is adjusted.

SC102-00 is given when LED light quantity does not complete.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


006

Latest: BO

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays white level peak scanning value (BLUE/ODD pixel) of LED light quantity adjustment.

Displays scanning levels of White reference plate when scanner powers on and LED light source lighting duty (PWM) is adjusted.

SC102-00 is given when LED light quantity does not complete.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

Main SP Tables - 4



4852

[LED White Level Peak Read]


001

Factory Setting: RE

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves white level peak scanning value (RED/EVEN pixel) of factory default LED light quantity adjustment.

Factory default white level peak scanning data will be saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


002

Factory Setting: RO

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves white level peak scanning value (RED/ODD pixel) of factory default LED light quantity adjustment.

Factory default white level peak scanning data will be saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


003

Factory Setting: GE

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves white level peak scanning value (GREEN/EVEN pixel) of factory default LED light quantity adjustment.

Factory default white level peak scanning data will be saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


004

Factory Setting: GO

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves white level peak scanning value (GREEN/ODD pixel) of factory default LED light quantity adjustment.

Factory default white level peak scanning data will be saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




005

Factory Setting: BE

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves white level peak scanning value (BLUE/EVEN pixel) of factory default LED light quantity adjustment.

Factory default white level peak scanning data will be saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).


006

Factory Setting: BO

*ENG

[0 to 1023 / 0 / 1digit/step]

Displays/Saves white level peak scanning value (BLUE/ODD pixel) of factory default LED light quantity adjustment.

Factory default white level peak scanning data will be saved during the main unit warranty process.

Use for design evaluation/analyzing cause of malfunction (abnormal image, SC).



4902

[Disp ACC Data]


001

R_DATA1

*ENG

[0 to 255 / 0 / 1/step]

Displays (0 to 255) scan value (R component) of scanner for AAC pattern (white background area)


002

G_DATA1

*ENG

[0 to 255 / 0 / 1/step]

Displays (0 to 255) scan value (G component) of scanner for AAC pattern (white background area)


003

B_DATA1

*ENG

[0 to 255 / 0 / 1/step]

Displays (0 to 255) scan value (B component) of scanner for AAC pattern (white background area)


004

R_DATA2

*ENG

[0 to 255 / 0 / 1/step]

Displays (0 to 255) scan value (R component) of scanner for AAC pattern (Cyan max. density area)

Main SP Tables - 4




005

G_DATA2

*ENG

[0 to 255 / 0 / 1/step]

Displays (0 to 255) scan value (G component) of scanner for AAC pattern (Magenta max. density area)


006

B_DATA2

*ENG

[0 to 255 / 0 / 1/step]

Displays (0 to 255) scan value (B component) of scanner for AAC pattern (Yellow max. density area)



4905

[Select Gradation Level]


001

-

*ENG

[0 to 255 / 0 / 1/step]

Sets when switching threshold matrix used for tone process.




4909

[Man Gamma:P ColK]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




4910

[Man Gamma:Txt:K]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]




4911

[Man Gamma:Txt:C]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]




4912

[Man Gamma:Txt:M]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

Main SP Tables - 4


002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]




4913

[Man Gamma:Txt:Y]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]




4914

[Man Gamma:T:ColK]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4


006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]




4915

[Man Gamma:Pht:K]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]




4916

[Man Gamma:Pht:C]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]

Main SP Tables - 4



4917

[Man Gamma:Pht:M]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]




4918

[Man Gamma:Pht:Y]

-

001

Offset:Highlight

*ENG

[0 to 30 / 15 / 1/step]

002

Offset:Middle

*ENG

[0 to 30 / 15 / 1/step]

003

Offset:Shadow

*ENG

[0 to 30 / 15 / 1/step]

004

Offset:IDmax

*ENG

[0 to 30 / 15 / 1/step]

005

Option:Highlight

*ENG

[0 to 255 / 0 / 1/step]

006

Option:Middle

*ENG

[0 to 12 / 0 / 1/step]

007

Option:Shadow

*ENG

[0 to 255 / 0 / 1/step]

008

Option:IDmax

*ENG

[0 to 255 / 0 / 1/step]

4918

[Man Gamma Adj]


009

-

ENG

[- / - / -]

Adjusts manual gamma with setting value of "Option-IDmax" against highlight, middle, shadow, and IdMax.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4


4930

[Coverage Ctrl: Text]


001

Copy: Full Color 1

*ENG

[0 to 400 / 200 / 1/step]

Sets text area total amount control value (0% to 400%) when full color copying with text/photo mode.


002

Copy: Full Color 2

*ENG

[0 to 400 / 200 / 1/step]

Sets text area total amount control value (0% to 400%) when full color copying with modes except text/photo mode.


003

Copy: Single Color

*ENG

[0 to 400 / 100 / 1/step]

Sets text area total amount control value (0% to 400%) when copying in color mode (B&W).


004

Copy: Color Conversion

*ENG

[0 to 400 / 180 / 1/step]

Sets text area total amount control value (0% to 400%) when copying in color mode (One color, Two colors).


005

Coverage Ctrl OFF

*ENG

[0 to 400 / 400 / 1/step]

Sets text area total amount control value (0% to 400%) when outputting image in other image output modes (normally, decontrolling total amount control)



4931

[Coverage Ctrl: Photo]


001

Copy: Full Color 1

*ENG

[0 to 400 / 240 / 1/step]

Sets photo area total amount control value (0% to 400%) when full color copying with text/photo mode.


002

Copy: Full Color 2

*ENG

[0 to 400 / 260 / 1/step]

Sets photo area total amount control value (0% to 400%) when full color copying with modes except text/photo mode.


003

Copy: Single Color

*ENG

[0 to 400 / 100 / 1/step]

Sets photo area total amount control value (0% to 400%) when copying in color mode (B&W).

004

Copy: Color Conversion

*ENG

[0 to 400 / 200 / 1/step]

Main SP Tables - 4



Sets photo area total amount control value (0% to 400%) when copying in color mode (One color, Two colors).


005

Coverage Ctrl OFF

*ENG

[0 to 400 / 400 / 1/step]

Sets photo area total amount control value (0% to 400%) when outputting image in other image output modes (normally, decontrolling total amount control)




4940

[Base Gamma Ctrl Pt:Txt K]

-


001


N.K.x1.y1


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




4941

[Base Gamma Ctrl Pt: Text C]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4942

[Base Gamma Ctrl Pt: Text M]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4943

[Base Gamma Ctrl Pt: Text Y]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4944

[Base Gamma Ctrl Pt: Photo K]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4945

[Base Gamma Ctrl Pt: Photo C]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4946

[Base Gamma Ctrl Pt: Photo M]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4947

[Base Gamma Ctrl Pt: Photo Y]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4948

[ACC Execute Time:Present]

-


001


yy/mm/dd


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



002


hh/mm/ss


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4949

[ACC Execute Time:Previous]

-


001


yy/mm/dd


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


hh/mm/ss


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]



4954

[Restore Test Chart]


005

Chromaticity Rank

ENG

[0 to 255 / 0 / 1/step]

Correct dispersion of scanner reading value among same models, based on the Color degree rank setting value of Scanner (front side).(Setting value0: Correction OFF)



4958

[Restore Test Chart: Rear]


005

Chromaticity Rank

ENG

[0 to 255 / 0 / 1/step]

Correct dispersion of scanner reading value among same models, based on the Color degree rank setting value of Scanner (rear side).(Setting value0: Correction OFF)




4960

[BaseGamma Ctrl Pt:Def:TxtK]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4961

[BaseGamma Ctrl Pt:Def:TxtC]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4962

[BaseGamma Ctrl Pt:Def:TxtM]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4964

[BaseGamma Ctrl Pt:Def:PhotoK]

-


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4965

[BaseGamma Ctrl Pt:Def:PhotoC]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


4966

[BaseGamma Ctrl Pt:Def:PhotoM]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


4966

[BaseGamma Ctrl Pt:Def:PhotoM]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


4966

[BaseGamma Ctrl Pt:Def:PhotoM]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4

Main SP Tables - 4




4967

[BaseGamma Ctrl Pt:Def:PhotoY]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4970

[Base Gamma Ctrl Pt:Prev:TxtK]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4971

[Base Gamma Ctrl Pt:Prev:TxtC]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4972

[Base Gamma Ctrl Pt:Prev:TxtM]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4973

[Base Gamma Ctrl Pt:Prev:TxtY]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



003


x4 y4 x5 y5


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4974

[Base Gamma Ctrl Pt:Prev:PhotoK]

-


001


N K x1 y1


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4975

[Base Gamma Ctrl Pt:Prev:PhotoC]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4976

[Base Gamma Ctrl Pt:Prev:PhotoM]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4977

[Base Gamma Ctrl Pt:Prev:PhotoY]

-


001


N K x1 y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2 y2 x3 y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4 y4 x5 y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6 y6 x7 y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8 y8 x9 y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10 y10 x11 y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



007


x12 y12 x13 y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14 y14 x15 y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16 y16


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4980

[IBACC Gamma Ctrl Pt: K]

-


001


N.K.x1.y1


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4




4981

[IBACC Gamma Ctrl Pt: C]

-


001


N.K.x1.y1


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4982

[IBACC Gamma Ctrl Pt: M]

-


001


N.K.x1.y1


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

Main SP Tables - 4



004


x6.y6.x7.y7


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


009


x16.y16


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4983

[IIBACC Gamma Ctrl Pt: Y]

-


001


N.K.x1.y1


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


002


x2.y2.x3.y3


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


003


x4.y4.x5.y5


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


004


x6.y6.x7.y7


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


005


x8.y8.x9.y9


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


006


x10.y10.x11.y11


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


007


x12.y12.x13.y13


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]


008


x14.y14.x15.y15


ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables - 4



009


x16.y16


*ENG

[0x00000000 to 0xFFFFFFFF /

0x00000000 / 1/step]




4984

[IBACC Target Den]

Sets reflecting rate (0 to 10) of copy IBACC correction against K, C, M, Y plate. As value enlarges, reflecting rate increases. Copy IBACC correction will not be done when setting to 0.

001

IBACC notch K

*ENG


[0 to 10 / 5 / 1/step]

002

IBACC notch C

*ENG

003

IBACC notch M

*ENG

004

IBACC notch Y

*ENG




4990

[IPU Memory Access]

-


001


-


*ENG

[0x000000 to 0xFFFFFF /

0x000000 / - /step]


002


Address Setting


*ENG

[0x000000 to 0xFFFFFFFF /

0x000000 / - /step]


003


Data Setting


*ENG

[0x000000 to 0x000000 / 0x000000

/ - /step]




4991

[IPU Memory Access]


001

RGB Frame Memory

ENG

[0 to 19 / 2 / 1/step]

002

Filter test output

*ENG

[0 to 28 / 24 / 1/step]

003

Data Setting

*ENG

[0 to 15 / 1 / 1/step]

004

Filter CPR output

ENG

[0 to 15 / 0 / 1/step]

Main SP Tables - 4



4993

[High Light Correction]


001


Sensitivity Selection


*ENG

[0 to 9 / 4 / 1/step]

0: Weak

9: Strong

Sets detect sensitivity for full color auto density. Larger the value, weaker (less background tracking) the sensitivity.


002


Range Selection


*ENG

[0 to 9 / 4 / 1/step]

0: Weak

9: Strong

Sets detect area for full color auto density. Larger the value, wider the area.



4994

[Adj Txt/Photo Recog Level]


001

High Compression PDF

*ENG

[0 to 2 / 1 / 1/step]

Adjusts the guide for recognize images text area and image area. Settings are 0: textish, 1: basic 2:imageish



4996

[White Paper Detection Level]


001

-

*ENG

[0 to 6 / 3 / 1/step]

Sets blank paper detect level. Larger the value, easier detecting.