6.13.2 OPERATION CHECK PROCEDURES OF THE TONER SUPPLY MOTOR/TONER BOTTLE DRIVE MOTOR
The operation check of the toner supply motor and/or toner bottle drive motor, is performed by a forced toner supply, not OUTPUT Check.
Operation other than the following procedures may occur the abnormal density, toner scattering, scumming, and cleaning failure at the image transfer unit.
1. Do [Force Tnr Supply :Exe (SP3-050-003 to 006)] for the applicable color twice. If there is enough toner in the toner supply unit, the toner bottle drive motor will not work.
SP No. | SP Name |
SP3-050-003 | Force Tnr Supply :Exe Execute: K |
SP3-050-004 | Force Tnr Supply :Exe Execute: C |
SP3-050-005 | Force Tnr Supply :Exe Execute: M |
SP3-050-006 | Force Tnr Supply :Exe Execute: Y |
2. Do [Manual ProCon :Exe Density Adjustment (SP3-011-002)] once.
If the operation of the toner bottle drive motor could not be checked, do step1 again after the manual execution of density adjustment.