When Abnormal Noise Occurs


Troubleshooting

Troubleshooting

Troubleshooting

6.13 WHEN ABNORMAL NOISE OCCURS


When abnormal noise occurs during machine operating, identify the occurrence location, by using various OUTPUT Check. However, about the following two modules, follow the checking procedure flow.

Check the abnormal noise of the drive unit (peripheral fusing)

Check the abnormal noise when the toner is supplied or the bottle motor is driving


Because the damage or contamination of parts can lead to secondary failure, always follow the procedure.

Take particular care not to be caught in the rotating parts of the motors and/or gears.


6.13.1 PROCEDURE OF CHECKING ABNORMAL NOISE OF DRIVE UNIT (PERIPHERAL FUSING)

When the abnormal noise of drive unit (peripheral fusing) has occurred, follow the following flow, and check whether the fusing unit is the cause, by using SP1-153 (Abnormal Noise Confirmation). If the fusing unit is the cause, replace the fusing unit. If the drive module is the cause, in addition perform the operation check of various motors by using OUTPUT Check, to identify which motor is the cause.

When Abnormal Noise Occurs


image

About the setting value of the operation line speed in SP1-153-003

During warming-up or operating on the operation panel, the motors rotate at low line speeds. At the time, if noise occurs, start checking from [2: Low Speed]. Middle speed is for only thick paper 1 printing, so use middle speed if abnormal noise occurs when thick paper 1 is supplied.

Related SP


SP No.

SP Name

Function

Description

SP1-153-001

Abnormal Noise Confirmation: Unit: Execute

The fusing motor rotates with the heating control.

Fails if the fusing unit is not installed or the cover is open

SP1-153-002

Abnormal Noise Confirmation: No Unit: Execute

The fusing motor rotates without the fusing unit.

Fails if the fusing unit is installed or the cover is open

Troubleshooting

Troubleshooting

Troubleshooting

When Abnormal Noise Occurs


SP No.

SP Name

Function

Description

SP1-153-003

Abnormal Noise Confirmation: Operation Line Speed

Line speed at the time of rotation

0: Standard speed

1: Middle speed

2: Low speed


SP1-153-004

Abnormal Noise Confirmation: Operation Time

Rotates during this time. Initial value: 60 sec.


SP1-153-005

Abnormal Noise Confirmation: Heat Center Target Temp

Temperature setting for SP1-153-001 (Unit:

Execute)

Do not change

SP1-153-006

Abnormal Noise Confirmation: Heat End Target Temp

Temperature setting for SP1-153-001 (Unit:

Execute)

SP1-153-007

Abnormal Noise Confirmation: Press Target Temp

Temperature setting for SP1-153-001 (Unit:

Execute)