HOME PAGE | < Previous | Contents | Next >

Troubleshooting for SC Errors


Troubleshooting

Troubleshooting

Troubleshooting

6.12.5 ISOLATION DIAGRAM OF SC663, 664, 665, 667, 668, AND 670-01

The modules considered to be the cause of SC663, 664, 665, 667, 668 and 670-01 are as follows.


image


6.12.6 WHEN SC670 (ENGINE START UP ERROR) IS DISPLAYED


Causes

The engine board resets at an unexpected time, and does not start up again.


Solutions

Note: CTL = Controller

SC670-01

Engine start up error when the machine boots up

If the symptom occurs, use the following chart to decide the best course of action.

Troubleshooting for SC Errors


image

SC670-02

Engine start up error when the machine is in operation.

Replace the part in order of precedence stated below (since there is a high possibility that those parts are broken and causing the error).

1. Replace BCU

2. Replace IPU

3. Replace CTL

4. Replace PSU

SC670-03

IPU start up error when the machine boots up.

Replace the part in order of precedence stated below (since there is a high possibility that those parts are broken and causing the error).

1. Replace IPU

2. Replace CTL

3. Replace PSU

4. Replace BCU.

SC670-04

Communication error between the engine and controller.

Replace the part in order of precedence stated below (since there is a high possibility that those parts are broken and causing the error).

1. Replace IPU

2. Replace BCU

3. Replace CTL