HOME PAGE | < Previous | Contents | Next >
Firmware Update (Auto Remote Firmware Update)
System Maintenance
System Maintenance
System Maintenance
Checking the ARFU Result
1. Enter the SP mode.
2. Press [Firmware update].
3. Press [Update].
4. Press [Update Package Information].
5. If the firmware package is the same as the one on the global server, the update was completed successfully. Otherwise, check the result using the logging date.
In SP7-520-041 to -045 (Update Log: Auto:Version), you can check the versions of the packages updated by ARFU. (-041 displays the latest result. It is also printed on the SMC sheet.)
Checking the Result Using the Logging Data
1. Enter the SP mode.
2. Press [System/Copy].
3. Check the results for ARFU by SP7-520-051 to 060 (Update Log: Auto:Result)
"-051" is the latest update result. For details about the number of each result log, see next section “Related SP.”
5.6.3 RELATED SP
SP Number | Selection Def. | Overview |
SP5-886-111 | 0: OFF 1: ON | Sets auto update ON/OFF by ARFU. |
SP5-886-112 | 0: OFF 1: ON | Will not run the update when update prohibited time setting is ON and the current time is in the range of the time set. Start time < End time: Prohibited time is from the start time to the end time on the same day. Start time > End time: Prohibited time is from the start time to the end time on the next day. Start time == End time: Prohibited time setting is disabled. (Update will not be prohibited.) |
SP5-886-113 | 0 to 23 9 | |
SP5-886-114 | 0 to 23 17 | |
SP5-886-115 | 0: OFF 1: ON | Even when the update function is disabled, downloading the package is allowed. The downloaded package can be used with SFU. |
Firmware Update (Auto Remote Firmware Update)
SP Number | Selection Def. | Overview |
SP5-886-116 | Display only | Displays when the latest package check will run. |
SP5-886-117 | 1 to 24 1 | Set time for the next version check after retry. |
SP5-886-120 | 0x00 | Update will not run if the corresponding bit for each day below is set to 1. prohibited:bit7 Monday: bit 6 Tuesday: bit 5 Wednesday: bit 4 Thursday: bit 3 Friday: bit 2 Saturday: bit 1 Sunday: bit 0 This setting is not affected by the prohibited time setting. e.g.) Prohibited on Mon., Fri., Sat., and Sun. : 0x47 (01000111) |
SP7-520-011 to 015 | Display only | History of date and time when update has started. The five most recent are recorded, the lowest number being most recent. If the last update failed, this is not recorded. |
SP7-520-021 to 025 | Display only | History of date and time when update has finished. The five most recent are recorded, the lowest number being most recent. The record is created when the update has successfully finished. When the update is cancelled, no record is created. |
SP7-520-031 to 035 | Display only | History of the package number (including suffix) for which update has completed. The five most recent are recorded, the lowest number being most recent. The record is created when the update has successfully finished. When the update is cancelled, no record is created. |
System Maintenance
System Maintenance
System Maintenance
Firmware Update (Auto Remote Firmware Update)
SP Number | Selection Def. | Overview |
SP7-520-041 to 045 | Display only | History of the package version for which update has completed. The five most recent are recorded, the lowest number being most recent. The record is created when the update has successfully finished. When the update is cancelled, no record is created. |
SP7-520-051 to 060 | Display only | History of the result of the download and the update. Refer below for the numbers set. |
Numbers set for the result history for SP7-520-051 to 060
No. | Result | Description |
1 | Downloading with SFU | Cannot download or update as the machine is now downloading the package for SFU. |
2 | HDD uninstalled | Cannot download or update as the machine has no HDD. |
3 | Updating with SFU | Cannot download or update as the machine is being updated with SFU. |
4 | HDD error | Cannot download or update as the HDD cannot be used. |
5 | Version information obtain error | Cannot download or update as the version information cannot be obtained. |
6 | Update download error | Cannot download or update as the update download failed. In non @Remote method, this shows that the download failed because there was no proxy set. |
7 | Name resolution error | Cannot download or update as the name cannot be resolved upon downloading the update. |
Firmware Update (Auto Remote Firmware Update)
No. | Result | Description |
8 | Auto update setting disabled | The package has been downloaded but will not run the update as SP5-886-111 (auto update setting) is disabled and SP5-886-115 (auto download setting for SFU) is enabled. |
9 | Update prohibited time | Cannot start to update as the auto update prohibited time setting (SP5-886-112) is enabled and the time update initiated was in the range of prohibited time (SP5-886-113 to 114). Or the day which update was initiated was a day for which update was prohibited (SP5-886-120). |
10 | Update postponed due to machine in use | Cannot start update due to the following conditions when update was initiated. The machine is in use by a user (the panel was used within 30 seconds) Machine offline for other reasons Operation prohibited Displaying SP/UP menu Firmware update is running with another method Configuration change prohibited Verifying the operation panel (smart panel) |
11 | Update cancelled by user | Update was cancelled because a user selected "Cancel" in the popup shown before starting the update. |
12 | Offline failed | Cannot start to update as the machine is offline for other reasons. |
13 | Update successful | Update was started and successfully completed. |
14 | Update failed | Update was started but failed. |
System Maintenance
System Maintenance
System Maintenance
Firmware Update (Auto Remote Firmware Update)
No. | Result | Description |
15 | Update deemed completed | Update was cancelled after the process was initiated because a user selected “Cancel”. There is no need to resume the update due to one of the following reasons: A newer update has been released and received. When retrying ARFU, the update has already been completed by another method. |
16 | Update cancelled by user after update initiated | Update was cancelled after the process initiated because a user selected "Cancel" during the update. |
17 | Version information obtain error (communication error occurred for hostname) | Cannot download or update as the name cannot be resolved when obtaining version information. |
18 | Version information obtain error (proxy verification failure) | Cannot download or update as the proxy verification failed with proxy settings when obtaining version information. |
19 | Version information obtain error (other than proxy verification failure when proxy is set) | Cannot download or update as an error other than proxy verification with proxy settings occurred when obtaining version information. |
20 | Update download error (proxy verification failure) | Cannot download or update as the proxy verification failed with proxy settings when downloading the package. |
21 | Update download error (other than proxy verification failure when proxy is set) | Cannot download or update as an error other than proxy verification with proxy settings occurred when downloading the package. |
Firmware Update (Auto Remote Firmware Update)
No. | Result | Description |
22 | Update by retry successful | After power failure, unsuccessful update, or rebooting, update by retry is executed successfully. However, this does not apply to the case where the update was cancelled after the process was initiated because a user selected “Cancel”. In this case, the update is “successful” if the retry is not executed between the start and completion of the next update (76 hours after the cancellation). |