HOME PAGE | < Previous | Contents | Next >

Image Adjustment



What It Does

SP code

Leading edge registration (Home Position Adj Value)

SP4-803-001

Side-to-Side Registration (Main Scan Reg)

SP4-011-001


Replacement and Adjustment

Replacement and Adjustment

Replacement and Adjustment

4.20.3 ARDF


ARDF Side-to-side, Leading Edge Registration and Trailing Edge


image

A: Leading edge registration

Use A3/DLT paper to make a temporary test chart as shown above.

1. Put the temporary test chart on the ARDF. Then make a copy from one of the feed stations.

2. Check the registration. Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.

Standard: 4.2 ± 2 mm for the leading edge registration, 2 ± 1 mm for the side-to-side registration. Use the following SP modes to adjust if necessary.


SP Code

What It Does

Adjustment Range

SP6-006-001

Side-to-Side Regist: Front

± 3.0 mm

SP6-006-003

Leading Edge Registration

± 5.0 mm

SP6-006-005

Buckle: Duplex Front

± 3.0 mm

SP6-006-006

Buckle: Duplex Rear

± 2.5 mm

SP6-006-007

Rear Edge Erase (Trailing Edge)

± 10.0 mm