Drive Unit


4.12.19 TRANSPORT COIL UNIT


Y

1. Image transfer belt unit (page 4-71)

2. PCDU (page 4-58)

3. Toner bottle drive motor (page 4-120)

4. Sub hopper (page 4-114)

5. ID chip contact board (page 4-122)

image

6. Put a piece of disposable paper [A] on the inside of the machine to avoid damage due to toner spillage.


image

7. Put a piece of disposable paper [A] under the transport coil to avoid damage due to toner spillage.


8. Remove all the harnesses connecting to the transport coil unit image×8).

Replacement and Adjustment

Replacement and Adjustment

Replacement and Adjustment

Drive Unit


image

9. Remove the screws fixing the transport coil units [A] image×5, each color).


image

10. Release the claws for the transport coil units [A] (claw ×1, each color).


image

11. Remove the screws securing the bracket [A] image×2).

image

12. Put a piece of disposable paper on the floor because toner can spill when you put the transport coil unit down.

Drive Unit


13. Pull out the whole transport coil unit [A] together with the bracket [B].

Be sure to put a piece of disposable paper on the floor because toner can spill when you put the transport coil unit down.

14. Transport coil unit for (Y) [A] (tab×1).

 

YMCK