HOME PAGE | < Previous | Contents | Next >

Image Transfer Unit


SP No.

Classification 1

Classification 2

Value

3-334-003

ID.Sens TestVal:C

Vct_reg Check:Slope

TM/ID sensor: C, value of [3]

3-334-004

ID.Sens TestVal:C

Vct_reg Check:Xint

TM/ID sensor: C, value of [4]

3-334-005

ID.Sens TestVal:C

Vct_dif Check:Slope

TM/ID sensor: C, value of [5]

3-334-006

ID.Sens TestVal:C

Vct_dif Check:Xint

TM/ID sensor: C, value of [6]

3-335-001

ID.Sens TestVal:R

K2: Check

TM/ID sensor: R, value of [1]

3-335-002

ID.Sens TestVal:R

Diffuse Corr

TM/ID sensor: R, value of [2]

3-335-003

ID.Sens TestVal:R

Vct_reg Check:Slope

TM/ID sensor: R, value of [3]

3-335-004

ID.Sens TestVal:R

Vct_reg Check:Xint

TM/ID sensor: R, value of [4]

3-335-005

ID.Sens TestVal:R

Vct_dif Check:Slope

TM/ID sensor: R, value of [5]

3-335-006

ID.Sens TestVal:R

Vct_dif Check:Xint

TM/ID sensor: R, value of [6]


Replacement procedure

1. Image transfer belt unit (page 4-71)

2. Paper transfer roller unit (page 4-89)

3. Fusing unit (page 4-129)

4. TM/ID sensor unit [A]


When installing the TM/ID sensor unit.

1. Attach the screw of the front side [B]

2. Attach the screw of the back side [C]

When installed in reverse order, an SC may occur because the sensor position has shifted.

Image Transfer Unit



image

5. Disconnect the connectors.


image

6. TM/ID sensor [A]


image