HOME PAGE | < Previous | Contents | Next >
SP No. | Classification 1 | Classification 2 | Value |
3-334-003 | ID.Sens TestVal:C | Vct_reg Check:Slope | TM/ID sensor: C, value of [3] |
3-334-004 | ID.Sens TestVal:C | Vct_reg Check:Xint | TM/ID sensor: C, value of [4] |
3-334-005 | ID.Sens TestVal:C | Vct_dif Check:Slope | TM/ID sensor: C, value of [5] |
3-334-006 | ID.Sens TestVal:C | Vct_dif Check:Xint | TM/ID sensor: C, value of [6] |
3-335-001 | ID.Sens TestVal:R | K2: Check | TM/ID sensor: R, value of [1] |
3-335-002 | ID.Sens TestVal:R | Diffuse Corr | TM/ID sensor: R, value of [2] |
3-335-003 | ID.Sens TestVal:R | Vct_reg Check:Slope | TM/ID sensor: R, value of [3] |
3-335-004 | ID.Sens TestVal:R | Vct_reg Check:Xint | TM/ID sensor: R, value of [4] |
3-335-005 | ID.Sens TestVal:R | Vct_dif Check:Slope | TM/ID sensor: R, value of [5] |
3-335-006 | ID.Sens TestVal:R | Vct_dif Check:Xint | TM/ID sensor: R, value of [6] |
Replacement procedure
1. Image transfer belt unit (page 4-71)
2. Paper transfer roller unit (page 4-89)
3. Fusing unit (page 4-129)
4. TM/ID sensor unit [A]
When installing the TM/ID sensor unit.
1. Attach the screw of the front side [B]
2. Attach the screw of the back side [C]
When installed in reverse order, an SC may occur because the sensor position has shifted.
Image Transfer Unit
5. Disconnect the connectors.
6. TM/ID sensor [A]