Image Transfer Unit


4.11.7 TM/ID SENSOR


Before Replacing the TM/ID sensor

Each sensor assembly has a list of characteristic values attached to it. Before you replace the TM/ID sensor, you must do the following procedure, or process control/MUSIC will not be done correctly after power is switched on (it will use the values for the old sensor).

The characteristic values attached to the service part must be entered before replacement. It is recommended that in case Process control/MUSIC after replacement is not completed successfully, take a note of values of SP3-333, SP3-334 and SP3-335.

1. Note the characteristic values that are listed on the bar code label.


image


TM/ID Sensor (front): F, TM/ID Sensor (center): C, TM/ID Sensor (rear): R, be careful.

2. Turn on the main power switch, and then go into the SP mode.

3. Input the characteristic values.

Input data for TM/ID Sensor: F into SP3-333. Input data for TM/ID sensor: C into SP3-334. Input data for TM/ID sensor: R into SP3-335.


SP No.

Classification 1

Classification 2

Value

3-333-001

ID.Sens TestVal:F

K2: Check

TM/ID sensor: F, value of [1]

3-333-002

ID.Sens TestVal:F

Diffuse Corr

TM/ID sensor: F, value of [2]

3-333-003

ID.Sens TestVal:F

Vct_reg Check:Slope

TM/ID sensor: F, value of [3]

3-333-004

ID.Sens TestVal:F

Vct_reg Check:Xint

TM/ID sensor: F, value of [4]

3-333-005

ID.Sens TestVal:F

Vct_dif Check:Slope

TM/ID sensor: F, value of [5]

3-333-006

ID.Sens TestVal:F

Vct_dif Check:Xint

TM/ID sensor: F, value of [6]

3-334-001

ID.Sens TestVal:C

K2: Check

TM/ID sensor: C, value of [1]

3-334-002

ID.Sens TestVal:C

Diffuse Corr

TM/ID sensor: C, value of [2]

Replacement and Adjustment

Replacement and Adjustment

Replacement and Adjustment