4.7 BIT SWITCHES - 5
Do not adjust a bit switch or use a setting that is described as "Not used", as this may cause the machine to malfunction or to operate in a manner that is not accepted by local regulations. Such bits are for use only in other areas, such as Japan.
Default settings for bit switches are not listed in this manual. Refer to the System Parameter List printed by the machine.
4.7.1 G3-2 AND G3-3 SWITCHES
These switches require an optional G3 interface unit. G3-3 switches are the same as for G3-2 switches.
G3-2 Switch 00 (SP No. 1-106-001) | ||||
No | Function | Comments | ||
0 1 | Monitor speaker during communication (tx and rx) | (0, 0): The monitor speaker is disabled all through the communication. (0, 1): The monitor speaker is on up to phase B in the T.30 protocol. (1, 0): Used for testing. The monitor speaker is on all through the communication. Make sure that you reset these bits after testing. | ||
Bit 1 | Bit 0 | Setting | ||
0 | 0 | Disable | ||
0 | 1 | Up to Phase B | ||
1 | 0 | All the time | ||
1 | 1 | Not used | ||
2 | Monitor speaker during memory transmission 0: Disabled 1: Enabled | 1: The monitor speaker is enabled during memory transmission. | ||
3-7 | Not used | Do not change the settings. |
Bit Switches - 5
G3-2 Switch 01 (SP No. 1-106-002) | ||
No | Function | Comments |
0-3 | Not used | Do not change the settings. |
4 | DIS frame length 0: 10 bytes 1: 4 bytes | 1: The bytes in the DIS frame after the 4th byte will not be transmitted (set to 1 if there are communication problems with PC-based faxes which cannot receive the extended DIS frames). |
5 | Not used | Do not change the setting. |
6 | Forbid CED/AMsam output 0: Off 1: On (Forbid output) | Do not change this setting (Default: 0: Off), unless communication problem is caused by a CED or ANSam transmission. |
7 | Not used | Do not change the setting. |
G3-2 Switch 02 (SP No. 1-106-003) | ||
No | Function | Comments |
0 | G3 protocol mode used 0: Standard and non-standard 1: Standard only | Change this bit to 1 only when the other end can only communicate with machines that send T.30-standard frames only. 1: Disables NSF/NSS signals (these are used in non-standard mode communication) |
1-6 | Not used | Do not change the settings. |
7 | Short preamble 0: Disabled 1: Enabled | Refer to Appendix B in the Group 3 Facsimile Manual for details about Short Preamble. |
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
Bit Switches - 5
G3-2 Switch 03 (SP No. 1-106-004) | ||
No | Function | Comments |
0 | DIS detection number (Echo countermeasure) 0: 1 1: 2 | 0: The machine will hang up if it receives the same DIS frame twice. 1: Before sending DCS, the machine will wait for the second DIS which is caused by echo on the line. |
1 | Not Used | Do not change the settings. |
2 | V.8 protocol 0: Disabled 1: Enabled | 0: V.8/V.34 communications will not be possible. Do not set to 0 unless the line condition is always bad enough to slow down the data rate to 14.4 kbps or lower. |
3 | ECM frame size 0: 256 bytes 1: 64 bytes | Keep this bit at "0" in most cases. |
4 | CTC transmission conditions 0: After one PPR signal received 1: After four PPR signals received (ITU-T standard) | 0: When using ECM in non-standard (NSF/NSS) mode, the machine sends a CTC to drop back the modem rate after receiving a PPR, if the following condition is met in communications at 14.4, 12.0, 9.6, and 7.2 kbps. Ntransmit = Number of transmitted frames Nresend = Number of frames to be retransmitted 1: When using ECM, the machine sends a CTC to drop back the modem rate after receiving four PPRs. PPR, CTC: These are ECM protocol signals. This bit is not effective in V.34 communications. |
Bit Switches - 5
5 | Modem rate used for the next page after receiving a negative code (RTN or PIN) 0: No change 1: Fallback | 1: The machine's tx modem rate will fall back before sending the next page if a negative code is received. This bit is ignored if ECM is being used. |
6 | Not used | Do not change the settings |
7 | Select detection of reverse polarity in ringing 0: Off 1: On | This switch is used to prevent reverse polarity in ringing on the phone line (applied to PSTN-G3 ringing). Do not change this setting 0: No detection 1: Detection (Japan and Korea only) |
G3-2 Switch 04 (SP No. 1-106-005) | ||
No | Function | Comments |
0-3 | Training error detection threshold | 0 - F (Hex); 0 - 15 bits If the number of error bits in the received TCF is below this threshold, the machine informs the sender that training has succeeded. |
4-7 | Not used | Do not change the settings. |
G3-2 Switch 05 (SP No. 1-106-006) | ||||||
No | Function | Comments | ||||
0-3 | Initial Tx modem rate (kbps) | These bits set the initial starting modem rate for transmission. Use the dedicated transmission parameters if you need to change this for specific receivers. If a modem rate 14.4 kbps or slower is selected, V.8 protocol should be disabled manually. Cross reference V.8 protocol on/off - G3 switch 03, bit 2 | ||||
Bit 3 | Bit 2 | Bit 1 | Bit 0 | kbps | ||
0 | 0 | 0 | 1 | 2.4 | ||
0 | 0 | 1 | 0 | 4.8 | ||
0 | 0 | 1 | 1 | 7.2 | ||
0 | 1 | 0 | 0 | 9.6 | ||
0 | 1 | 0 | 1 | 12.0 |
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
Bit Switches - 5
0 | 1 | 1 | 0 | 14.4 | ||
0 | 1 | 1 | 1 | 16.8 | ||
1 | 0 | 0 | 0 | 19.2 | ||
1 | 0 | 0 | 1 | 21.6 | ||
1 | 0 | 1 | 0 | 24.0 | ||
1 | 0 | 1 | 1 | 26.4 | ||
1 | 1 | 0 | 0 | 28.8 | ||
1 | 1 | 0 | 1 | 31.2 | ||
Other settings - Not used | ||||||
4-5 | Initial modem type for 9.6 k or 7.2 kbps. | These bits set the initial modem type for 9.6 and 7.2 kbps, if the initial modem rate is set at these speeds. | ||||
Bit 5 | Bit 4 | Setting | ||||
0 | 0 | V.29 | ||||
0 | 1 | V.17 | ||||
1 | 0 | V.34 | ||||
1 | 1 | Not used | ||||
6-7 | Not used | Do not change the settings. |
Bit Switches - 5
G3-2 Switch 06 (SP No. 1-106-007) | ||||||
No | Function | Comments | ||||
0-3 | Initial Rx modem rate(kbps) | These bits set the initial starting modem rate for reception. Use a lower setting if high speeds pose problems during reception. If a modem rate 14.4 kbps or slower is selected, V.8 protocol should be disabled manually. Cross reference V.8 protocol on/off - G3 switch 03, bit2 | ||||
Bit 3 | Bit 2 | Bit 1 | Bit 0 | kbps | ||
0 | 0 | 0 | 1 | 2.4 | ||
0 | 0 | 1 | 0 | 4.8 | ||
0 | 0 | 1 | 1 | 7.2 | ||
0 | 1 | 0 | 0 | 9.6 | ||
0 | 1 | 0 | 1 | 12.0 | ||
0 | 1 | 1 | 0 | 14.4 | ||
0 | 1 | 1 | 1 | 16.8 | ||
1 | 0 | 0 | 0 | 19.2 | ||
1 | 0 | 0 | 1 | 21.6 | ||
1 | 0 | 1 | 0 | 24.0 | ||
1 | 0 | 1 | 1 | 26.4 | ||
1 | 1 | 0 | 0 | 28.8 | ||
1 | 1 | 0 | 1 | 31.2 | ||
Other settings - Not used | ||||||
4-7 | Modem types available for reception The setting of these bits is used to inform the transmitting terminal of the available modem type for the machine in receive mode. If V.34 is not selected, V.8 protocol must be disabled manually. Cross reference V.8 protocol on/off - G3 switch 03, bit 2 | |||||
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Types | ||
0 | 0 | 0 | 1 | V.27ter |
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
Bit Switches - 5
0 | 0 | 1 | 0 | V.27ter | |
0 | 0 | 1 | 1 | V.27ter | |
0 | 1 | 0 | 0 | V.27ter | |
0 | 1 | 0 | 1 | V.27ter | |
Other settings - Not used |
Bit Switches - 5
G3-2 Switch 07 (SP No. 1-106-008) | |||||
No | Function | Comments | |||
0-1 | PSTN cable equalizer (tx mode: Internal) | Use a higher setting if there is signal loss at higher frequencies because of the length of wire between the modem and the telephone exchange. Use the dedicated transmission parameters for specific receivers. Also, try using the cable equalizer if one or more of the following symptoms occurs. Communication error Modem rate fallback occurs frequently. This setting is not effective in V.34 communications. | |||
Bit 1 | Bit 0 | Setting | |||
0 | 0 | None | |||
0 | 1 | Low | |||
1 | 0 | Medium | |||
1 | 1 | High | |||
2-3 | PSTN cable equalizer (rx mode: Internal) | Use a higher setting if there is signal loss at higher frequencies because of the length of wire between the modem and the telephone exchange. Also, try using the cable equalizer if one or more of the following symptoms occurs. Communication error with error codes such as 0-20, 0-23, etc. Modem rate fallback occurs frequently. This setting is not effective in V.34 communications. | |||
Bit 3 | Bit 2 | Setting | |||
0 | 0 | None | |||
0 | 1 | Low | |||
1 | 0 | Medium | |||
1 | 1 | High | |||
4 | PSTN cable equalizer (V.8/V.17 rx mode: External) 0: Disabled 1: Enabled | Keep this bit at "1". |
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
Fax Option Type 5002 (D629)
5-7 | Not used | Do not change the settings. |
5-7 | Not used | Do not change the settings. |
5-7 | Not used | Do not change the settings. |
G3-2 Switch 08 - Not used (do not change the settings) |
G3-2 Switch 09 - Not used (do not change the settings) |
G3-2 Switch 08 - Not used (do not change the settings) |
G3-2 Switch 09 - Not used (do not change the settings) |
G3-2 Switch 08 - Not used (do not change the settings) |
G3-2 Switch 09 - Not used (do not change the settings) |
Bit Switches - 5
G3-2 Switch 0A (SP No. 1-106-011) | ||||
No | Function | Comments | ||
0-1 | Maximum allowable carrier drop during image data reception | These bits set the acceptable modem carrier drop time. Try a longer setting if error code 0-22 is frequent. | ||
Bit 1 | Bit 0 | Value (ms) | ||
0 | 0 | 200 | ||
0 | 1 | 400 | ||
1 | 0 | 800 | ||
1 | 1 | Not used | ||
2 | Select cancellation of high-speed RX if carrier signal lost while receiving 0: Off 1: On | This switch setting determines if high-speed receiving ends if the carrier signal is lost when receiving during non-ECM mode | ||
3 | Not used | Do not change the settings | ||
4 | Maximum allowable frame interval during image data reception. 0: 5 s 1: 13 s | This bit set the maximum interval between EOL (end-of-line) signals and the maximum interval between ECM frames from the other end. Try using a longer setting if error code 0-21 is frequent. | ||
5 | Not used | Do not change the settings. |