Blown Fuse Conditions


6.3 BLOWN FUSE CONDITIONS



image

Use a correct rating fuse for the fuse replacement. Never use a wrong rating fuse. If do so, the machine may be damaged.



Fuse

Rating


Symptom at power on

115V

210 to 230V

Power Supply Board

FU21

6.3A / 250V

6.3A / 250V

SC 533 (Power to IOB)

FU22

6.3A / 250V

6.3A / 250V

SC 144-02 (Power to SIO)


FU23


10A / 250V


10A / 250V

"Open Cover" is displayed. (Power to Interlock Switch)


FU24


10A / 250V


10A / 250V

"Open Cover" is displayed. (Power to Interlock Switch)


FU25


6.3A / 250V


6.3A / 250V

Alert LED turns on and operation panel does not turn on. (Power to MB)


FU26


6.3A / 250V


6.3A / 250V

Stack paper in the optional paper feed unit or LCT is not detected. SC 503 is issued after opening and closing the tray 3 or 4. (Power to optional PFU or LCT)


FU27


6.3A / 250V


6.3 A/ 250V

The machine does not detect a finisher. (Power to optional Finisher)

FU101

15A / 250V

8A / 250V

No response

FU102

12A / 250V

4A / 250V

No response