HOME PAGE | < Previous | Contents | Next >
Component (Symbol) | CN | Condition | Symptom |
Platen Cover | 318-5 (SIO) | Open | APS and ARE do not function properly. |
Shorted | No symptom. | ||
Original Length 1 | 313-2 (SIO) | Open/ Shorted | CPU cannot detect the original size properly. APS and ARE do not function correctly. |
Original Length 2 | 313-8 (SIO) | Open/ Shorted | CPU cannot detect the original size properly. APS and ARE do not function correctly. |
Trouble- shooting
Trouble- shooting
Trouble- shooting
6.2.2 SWITCHES
Component (Symbol) | CN | Condition | Symptom |
Right Door | 221-B10 (IOB) | Open | "Open Cover" is displayed even if the right door is closed. |
Shorted | The LCD goes blank when the right door is opened. | ||
Main Power | 903-1,2 (PSU) | Open | The machine does not turn on. |
Shorted | The machine does not turn off. | ||
Interlock | 913-1,2 (PSU) | Open | "Doors/Covers Open" is displayed even if the front or right door is closed. |
Shorted | The LCD goes blank when the front or right door is opened. |