5.5 MAIN SP TABLES-3
5.5.1 SP3-XXX: PROCESS
3001 | P Sensor Setting | |
001* | Current | [0 to 43 / 13 / 0.1 mA ] |
Allows you to reset the PWM of the ID sensor LED to avoid a service call error after clearing NVRAM or replacing the NVRAM. The PWM data is stored by executing SP-3001-2. | ||
002 | Initialization | - |
Performs the ID sensor initial setting. ID sensor output for the bare drum (VSG) is adjusted automatically to 4.0 ±0.2 V. Press "Execute" to start. Perform this setting after replacing or cleaning the ID sensor, replacing the drum, or clearing NVRAM. |
3045* | Toner End Setting DFU | |
001 | ON/OFF | [0 to 1 / 0 / 1] 0=Off, 1=On |
3902* | New PCU Detection (Not used) | |
001 | ON/OFF Setting | [0 to 1 / 0 / 1] 0: On, 1: Off |
Turns on or off the new unit detection for the transfer belt unit and fusing unit. |