4.16.5 TOUCH SCREEN CALIBRATION

After clearing the memory, replacing the operation panel or NVRAM, or if the touch panel detection function is not working correctly, follow this procedure to calibrate the touch screen.

Do not attempt to use items [2] to [7] on the Self-Diagnostic Menu. These items are for design use only.

image

Replacement and Adjustment

Replacement and Adjustment

Replacement and Adjustment

1. Press image, "1", "9", "9", "3", and then press image 5 times to open the Self-Diagnostics menu.

2. On the touch screen press "Touch Screen Adjust" (or press "1").


image

3. Use a pointed (not sharp!) tool to press the upper left mark image.

4. Press the lower right mark image after it appears.

5. Touch a few spots on the touch panel to confirm that the marker (+) appears exactly where the screen is touched.

If the + mark does not appear where the screen is touched, press Cancel and repeat from Step 2.

6. When you are finished, press [#] OK on the screen (or press image).

7. Touch [#] Exit on the screen to close the Self-Diagnostic menu and save the calibration settings.