HOME PAGE | < Previous | Contents | Next >

Copy Adjustments: Printing/Scanning

Rev. 12/27/2012


4.16.3 SCANNING

Before doing the following scanner adjustments, perform or check the printing registration/side-to-side adjustment and the blank margin adjustment.

Use the S5S test chart to perform the following adjustments.


Registration: Platen Mode


image

1. Place the test chart on the exposure glass and make a copy from one of the feed stations.

2. Check the leading edge [A] and side-to-side [B] registration, and adjust them with the following SP modes if necessary.



SP No.

Specification

Leading Edge

SP4-010-1

0 ±2.0 mm

Side-to-side

SP4-011-1

0 ±2.5 mm


D129/D130 4-114 SM

 

Registration: Platen ModeMagnification