HOME PAGE | < Previous | Contents | Next >

Rev. 12/27/2012

Copy Adjustments: Printing/Scanning


Magnification

Use the S5S test chart to perform the following adjustment.

Sub Scan Magnification


image


Replacement and Adjustment

Replacement and Adjustment

Replacement and Adjustment

1. Place the test chart on the exposure glass and make a copy from one of the feed stations.

2. Check the magnification ratio. Use SP4-008 (Scanner Sub Scan Magnification) to adjust if necessary. Specification: ±0.9%.



SM 4-115 D129/D130