6. Disconnect the connector [A] on the scanner lamp.
7. Pull out the scanner lamp [A].
Chromaticity rank adjustment
Each scanner lamp has a specific chromaticity rank. The chromaticity rank is indicated by the bar-code on the new scanner lamp. After replacing the lamp, adjust the chromaticity rank to correspond to the new scanner lamp.
1. Check the first three digits [A] in the bar-code on the new scanner lamp before installing the new lamp.
Scanner
Replacement and Adjustment
Replacement and Adjustment
Replacement and Adjustment
2. After installing the new lamp, go to SP4-954-005 and enter the SP setting number referring to the table below.
1st Three Digits | SP Setting (SP4-954-005) | 1st Three Digits | SP Setting (SP4-954-005) |
139 | 3 | 166 | 12 |
140 | 2 | 167 | 11 |
141 | 1 | 168 | 10 |
142 | 6 | 169 | 15 |
143 | 5 | 170 | 14 |
144 | 4 | 171 | 13 |
145 | 9 | 172 | 18 |
146 | 8 | 173 | 17 |
147 | 7 | 174 | 16 |
148 | 12 | 204 | 3 |
149 | 11 | 205 | 2 |
150 | 10 | 206 | 1 |
151 | 15 | 207 | 6 |
152 | 14 | 208 | 5 |
153 | 13 | 209 | 4 |
154 | 18 | 210 | 9 |
155 | 17 | 211 | 8 |
156 | 16 | 212 | 7 |
157 | 3 | 213 | 12 |
158 | 2 | 214 | 11 |
159 | 1 | 215 | 10 |
160 | 6 | 216 | 15 |