When reassembling
Adjust the following SP modes after you replace the lens block assembly:
SP4–008 (Sub Scan Mag): "Scanning" in "Copy Adjustments: Printing/Scanning")
SP4–010 (Sub Mag Reg.): "Scanning" in "Copy Adjustments: Printing/Scanning")
SP4–011 (Main Scan Reg): "Scanning" in "Copy Adjustments: Printing/Scanning")
SP4–688 (DF: Density Adjustment): Use this to adjust the density level if the ID of outputs made in the DF and Platen mode is different.
4.4.4 ORIGINAL SIZE SENSOR
1. Exposure glass with left scale p.4-10 "Exposure Glass")
2. Scanner right cover p.4-11 "Scanner Exterior Panels and Operation Panel")
Replacement and Adjustment
Replacement and Adjustment
Replacement and Adjustment
3. SBU cover p.4-14 "Lens Block Assembly")
4. Remove the screw [A] on the sensor board bracket.
5. Circuit chip [A] x 1, x 1)
Scanner
6. Original size sensor bracket [A] x 2)
7. Original size sensors [A] (hooks)