HOME PAGE | < Previous | Contents | Next >
Input and Output Check
Input and Output Check
Input and Output Check
3.2 OUTPUT CHECK TABLE
5804 | [OUTPUT Check] | ||
001 | Feed Pickup Solenoid 1 | ENG | [0 or 1 / 0 / 1/step] |
Moves 1st paper feed tray pick up solenoid. | |||
002 | Feed Pickup Solenoid 2 | ENG | [0 or 1 / 0 / 1/step] |
Moves 2nd paper feed tray pick up solenoid. | |||
003 | Bypass Pickup Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Moves bypass pick up solenoid. | |||
004 | Exit Junction Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Moves output paper divide solenoid. | |||
5804 | [OUTPUT Check] | ||
Moves paper feed tray rising motor. | |||
005 | Tray 1 Lift Motor:CW | ENG | [0 or 1 / 0 / 1/step] |
006 | Tray 1 Lift Motor:CCW | ENG | |
007 | Tray 2 Lift Motor:CW | ENG | |
008 | Tray 2 Lift Motor:CCW | ENG | |
5804 | [OUTPUT Check] | ||
Moves register motor. | |||
009 | Regist Motor:CCW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
010 | Regist Motor:CCW:Middle Speed | ENG | |
011 | Regist Motor:CCW:Low Speed | ENG |
Output Check Table
5804 | [OUTPUT Check] | ||
015 | Regist Motor:Position Hold | ENG | [0 or 1 / 0 / 1/step] |
Holds position of register motor. | |||
5804 | [OUTPUT Check] | ||
Moves paper feed motor. | |||
016 | Feed Motor:CW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
017 | Feed Motor:CW:Middle Speed | ENG | |
018 | Feed Motor:CW:Low Speed | ENG | |
022 | Feed Motor:CCW:Standard Speed | ENG | |
023 | Feed Motor:CCW:Middle Speed | ENG | |
024 | Feed Motor:CCW:Low Speed | ENG | |
5804 | [OUTPUT Check] | ||
Moves vertical carry motor. | |||
028 | Bypass V-Transport Motor:CW:Std Speed | ENG | [0 or 1 / 0 / 1/step] |
029 | Bypass V-Transport Motor:CW:Middle Speed | ENG | |
030 | Bypass V-Transport Motor:CW:Low Speed | ENG | |
5804 | [OUTPUT Check] | ||
034 | Bypass V-Transport Motor:Position Hold | ENG | [0 or 1 / 0 / 1/step] |
Holds position of vertical carry motor. | |||
037 | Exit Motor: CW: Fusing Pressure Release | ENG | [0 or 1 / 0 / 1/step] |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
Moves fusing dis-pressure. | |||
5804 | [OUTPUT Check] | ||
Moves paper exit motor. | |||
041 | Exit Motor:CCW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
042 | Exit Motor:CCW:Middle Speed | ENG | |
043 | Exit Motor:CCW:Low Speed | ENG | |
5804 | [OUTPUT Check] | ||
Moves reverse motor. | |||
047 | Inverter Motor:CW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
048 | Inverter Motor:CW:Middle Speed | ENG | |
049 | Inverter Motor:CW:Low Speed | ENG | |
052 | Inverter Mt: CW: Normal Speed: Duplex | ENG | |
054 | Inverter Mt: CW: Low Speed: Duplex | ENG | |
056 | Inverter Motor:CCW:Standard Speed | ENG | |
057 | Inverter Motor:CCW:Middle Speed | ENG | |
058 | Inverter Motor:CCW:Low Speed | ENG | |
061 | Inverter Mt: CCW: Normal Speed: Inc Speed | ENG |
Output Check Table
5804 | [OUTPUT Check] | ||
Moves duplex entrance motor. | |||
065 | Duplex Entrance Motor:CW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
066 | Duplex Entrance Motor:CW:Middle Speed | ENG | |
067 | Duplex Entrance Motor:CW:Low Speed | ENG | |
068 | Duplex Entrance Motor: Normal Speed: Duplex | ENG | |
069 | Duplex Entrance Motor: Low Speed: Duplex | ENG | |
5804 | [OUTPUT Check] | ||
Moves duplex bypass motor. | |||
071 | Duplex Bypass Motor:CW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
072 | Duplex Bypass Motor:CW:Middle Speed | ENG | |
073 | Duplex Bypass Motor:CW:Low Speed | ENG | |
074 | Duplex Bypass Motor: CW: Normal Speed: Dup | ENG | |
075 | Duplex Bypass Motor: CW: Low Speed: Duplex | ENG | |
077 | Duplex Bypass Motor:CCW:Standard Speed | ENG | |
078 | Duplex Bypass Motor:CCW:Middle Speed | ENG |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
079 | Duplex Bypass Motor:CCW:Low Speed | ENG | |
080 | Duplex Bypass Motor: CCW: Normal Speed: Feed | ENG | |
081 | Duplex Bypass Motor: CCWr: Low Speed: Feed | ENG | |
5804 | [OUTPUT Check] | ||
083 | Duplex Bypass Motor:Position Hold | ENG | [0 or 1 / 0 / 1/step] |
Holds position of duplex bypass motor. | |||
084 | SI Bypass SF Drive Motor:CW (500pps) | ENG | [0 or 1 / 0 / 1/step] |
Moves SI bypass SF drive motor. | |||
085 | SI Bypass SF Dr M:CW:PlsCnt:460Pls(2mm) | ENG | [0 or 1 / 0 / 1/step] |
Moves SI bypass SF drive motor for 2mm. | |||
086 | SI Bypass SF Dr M:CW:PlsCnt:920Pls(4mm) | ENG | [0 or 1 / 0 / 1/step] |
Moves SI bypass SF drive motor for 4mm. | |||
087 | SI Bypass SF Drive Motor:CCW (500pps) | ENG | [0 or 1 / 0 / 1/step] |
Moves SI bypass SF drive motor. | |||
088 | SI Bypass SF Dr M:CCW:PlsCnt:920Pls(2mm) | ENG | [0 or 1 / 0 / 1/step] |
Moves SI bypass SF drive motor for 2mm. | |||
089 | SI Bypass SF Dr M:CCW:PlsCnt:920Pls(4mm) | ENG | [0 or 1 / 0 / 1/step] |
Moves SI bypass SF drive motor for 4mm. |
Output Check Table
5804 | [OUTPUT Check] | ||
Moves fusing motor. *See Important below | |||
092 | Fusing Motor:CW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
093 | Fusing Motor:CW:Middle Speed | ENG | |
094 | Fusing Motor:CW:Low Speed | ENG | |
098 | Fusing Motor:CCW:Low Speed | ENG | |
Important: Use the procedure below to do the output checks for the fusing exit motor. If you do not follow this procedure, a kink will form in the fusing belt sleeve, and the fusing sleeve belt unit will need to be replaced. 1. Do one of the following:  Open the right cover of the paper bank  Remove one of the toner bottles  Pull out the waste toner bottle half-way  Remove the fusing unit 2. Enter SP mode. 3. Do the following out output checks:  SP5-804-092 (Fusing Motor:CW:Standard Speed)  SP5-804-093 (Fusing Motor:CW:Middle Speed)  SP5-804-094 (Fusing Motor:CW:Low Speed)  SP5-804-098 (Fusing Motor:CCW:Low Speed) 4. Without exiting SP mode, turn the main power switch off and then on again. Important: If you exit SP mode before you turn the main power switch off, the fusing exit motor will stay off when the machine warms up. Heat will be concentrated in one area of the fusing belt sleeve and cause a kink to form. If this happens, you will need to replace the fusing sleeve belt unit. 5. Do the reverse of what you did in step 1 (for example, reattach the fusing unit). | |||
5804 | [OUTPUT Check] | ||
104 | Polygon Motor: L | ENG | [0 or 1 / 0 / 1/step] |
Runs motor with 21969 rpm. |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
105 | Polygon Motor: M | ENG | [0 or 1 / 0 / 1/step] |
Runs motor with 25512 rpm. | |||
106 | Polygon Motor: H | ENG | [0 or 1 / 0 / 1/step] |
Runs motor with 30236 rpm. | |||
107 | Polygon Motor: HH | ENG | [0 or 1 / 0 / 1/step] |
Runs motor with 34488 rpm. | |||
110 | Fusing Fan: Full Speed | ENG | [0 or 1 / 0 / 1/step] |
Moves fusing exhaust heat fan. | |||
111 | Fusing Fan: Half Speed | ENG | [0 or 1 / 0 / 1/step] |
Moves fusing exhaust heat fan. | |||
112 | Dev Fan: Left/Toner Supply Cooling Fan | ENG | [0 or 1 / 0 / 1/step] |
Moves develop left exhaust air fan and toner supply cooling fan. | |||
113 | PSU Cooling/Exhaust Heat Fan | ENG | [0 or 1 / 0 / 1/step] |
Moves PSU cooling fan and exhaust heat fan. | |||
114 | Ozone Fan | ENG | [0 or 1 / 0 / 1/step] |
Moves ozone exhaust heat fan. | |||
115 | PCB Box Cooling Fan: Full Speed | ENG | [0 or 1 / 0 / 1/step] |
Moves electric BOX cooling fan. | |||
116 | PCB Box Cooling Fan: Half Speed | ENG | [0 or 1 / 0 / 1/step] |
Moves electric BOX cooling fan. | |||
117 | Development: Right/DriveCooling/MainFan | ENG | [0 or 1 / 0 / 1/step] |
Moves main unit exhaust heat fan, develop right exhaust air fan, driver cooler. |
Output Check Table
118 | ExhaustCooling Fan | ENG | [0 or 1 / 0 / 1/step] |
Moves paper exit cooling fan. | |||
119 | Development Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Moves develop solenoid. | |||
5804 | [OUTPUT Check] | ||
Moves develop motor. | |||
120 | Development Motor K: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
121 | Development Motor K: Middle Speed | ENG | |
122 | Development Motor K: Low Speed | ENG | |
128 | Development Motor FC: Standard Speed | ENG | |
129 | Development Motor FC: Middle Speed | ENG | |
130 | Development Motor FC: Low Speed | ENG | |
5804 | [OUTPUT Check] | ||
Moves drum motor FC. | |||
132 | Drum Motor FC: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
133 | Drum Motor FC: Middle Speed | ENG | |
134 | Drum Motor FC: Low Speed | ENG | |
5804 | [OUTPUT Check] | ||
Moves transfer drum motor K. | |||
136 | Transfer Drum Motor K: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
137 | Transfer Drum Motor K: Middle Speed | ENG | |
138 | Transfer Drum Motor K: Low Speed | ENG | |
5804 | [OUTPUT Check] | ||
Moves paper transfer divide motor. | |||
140 | PTR Contact Motor:CW | ENG | [0 or 1 / 0 / 1/step] |
141 | PTR Contact Motor:CCW | ENG | |
5804 | [OUTPUT Check] | ||
Moves toner supply motor. | |||
142 | Toner Supply Motor Y: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
146 | Toner Supply Motor M:CCW:Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
150 | Toner Supply Motor M:CW:(ITB Contact) | ENG | [0 or 1 / 0 / 1/step] |
Moves image transfer divide motor (reverse to toner supply motor M). | |||
151 | Toner Supply Motor C: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
155 | Toner Supply Motor K: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
5804 | [OUTPUT Check] | ||
Moves toner bottle drive motor. | |||
159 | Toner Bottle Drive Motor Y | ENG | [0 or 1 / 0 / 1/step] |
160 | Toner Bottle Drive Motor M | ENG | |
161 | Toner Bottle Drive Motor C | ENG | |
162 | Toner Bottle Drive Motor K | ENG |
Output Check Table
5804 | [OUTPUT Check] | ||
Moves relay carry motor (bridge unit)/left paper exit carry motor (left paper exit tray). | |||
163 | Bridge Relay/Left Exit Motor: Normal Speed | ENG | [0 or 1 / 0 / 1/step] |
164 | Bridge Relay/Left Exit Motor: Middle Speed | ENG | |
165 | Bridge Relay/Left Exit Motor: Low Speed | ENG | |
166 | Bridge Relay/Left Ex Mt: Normal Speed Upper | ENG | |
5804 | [OUTPUT Check] | ||
169 | Bridge Junction/Left Exit Junction Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Moves relay divide solenoid (bridge unit)/left paper exit divide solenoid (left paper exit tray). | |||
170 | Shift Tray Motor:CW | ENG | [0 or 1 / 0 / 1/step] |
Moves shift tray motor. | |||
171 | Shift Tray Motor:CCW | ENG | [0 or 1 / 0 / 1/step] |
Moves shift tray motor. | |||
172 | Toner End Sensor: K Power | ENG | [0 or 1 / 0 / 1/step] |
Supples power to toner end sensor (K). | |||
173 | Toner End Sensor: FC Power | ENG | [0 or 1 / 0 / 1/step] |
Supples power to toner end sensor (FC). | |||
175 | Drum PCL: FC | ENG | [0 or 1 / 0 / 1/step] |
Lights (PWM drive) the drum PCL (FC). |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
5804 | [OUTPUT Check] | ||
Outputs PWM for electrify HVP (DC/AC:Y/M/C/K). | |||
176 | PP: Charge DC: Y | ENG | [0 or 1 / 0 / 1/step] |
177 | PP: Charge DC: M | ENG | |
178 | PP: Charge DC: C | ENG | |
179 | PP: Charge DC: K | ENG | |
180 | PP: Charge AC: Y | ENG | |
181 | PP: Charge AC: M | ENG | |
182 | PP: Charge AC: C | ENG | |
183 | PP: Charge AC: K | ENG | |
5804 | [OUTPUT Check] | ||
Outputs PWM for develop HVP. | |||
184 | PP: Development: Y | ENG | [0 or 1 / 0 / 1/step] |
185 | PP: Development: M | ENG | |
186 | PP: Development: C | ENG | |
187 | PP: Development: K | ENG | |
5804 | [OUTPUT Check] | ||
Outputs PWM for divide HVP. | |||
194 | PP: Separation | ENG | [0 or 1 / 0 / 1/step] |
5804 | [OUTPUT Check] | ||
Outputs PWM for transfer HVP (image transfer: Y/M/C/K). | |||
195 | PP: ITB: Y | ENG | [0 or 1 / 0 / 1/step] |
196 | PP: ITB: M | ENG | |
197 | PP: ITB: C | ENG | |
198 | PP: ITB: K | ENG |
Output Check Table
5804 | [OUTPUT Check] | ||
Outputs PWM for transfer HVP (paper transfer: +/-). | |||
199 | PP: PTR: + | ENG | [0 or 1 / 0 / 1/step] |
200 | PP: PTR: - | ENG | |
5804 | [OUTPUT Check] | ||
201 | Duplex Guide Plate Open/Close LED | ENG | [0 or 1 / 0 / 1/step] |
Lights duplex guide plate open/close LED. | |||
5804 | [OUTPUT Check] | ||
202 | Scanner Lamp | ENG | [0 or 1 / 0 / 1/step] |
Checks output of scanner lamp. Use to check light source malfunction when SC101-01, SC101-02, SC102-00, SC142-00 occurs. | |||
206 | PTR Open/Close LED | ENG | [0 or 1 / 0 / 1/step] |
Lights paper transfer open/close LED. | |||
208 | TM/P Sensor: F | ENG | [0 or 1 / 0 / 1/step] |
Lights TM/P sensor: Front glowing part. | |||
209 | TM/P Sensor: C | ENG | [0 or 1 / 0 / 1/step] |
Lights TM/P sensor: Center glowing part. | |||
210 | TM/P Sensor: R | ENG | [0 or 1 / 0 / 1/step] |
Lights TM/P sensor: Rear glowing part. | |||
211 | HST Sensor Power | ENG | [0 or 1 / 0 / 1/step] |
Powers the HST sensor. | |||
5804 | [OUTPUT Check] | ||
Outputs PWM (Vcnt) to HST sensor: Y/M/C/K | |||
212 | HST Sensor: Y | ENG | [0 or 1 / 0 / 1/step] |
213 | HST Sensor: M | ENG |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
214 | HST Sensor: C | ENG | |
215 | HST Sensor: K | ENG | |
5804 | [OUTPUT Check] | ||
output check: LD1~LD4:Bk,Ma,Cy,Ye: Bk. Means that polygon lights when rotating. | |||
216 | LD1: K | ENG | [0 or 1 / 0 / 1/step] |
217 | LD2: K | ENG | |
218 | LD3: K | ENG | |
219 | LD4: K | ENG | |
220 | LD1: M | ENG | |
221 | LD2: M | ENG | |
222 | LD3: M | ENG | |
223 | LD4: M | ENG | |
224 | LD1: C | ENG | |
225 | LD2: C | ENG | |
226 | LD3: C | ENG | |
227 | LD4: C | ENG | |
228 | LD1: Y | ENG | |
229 | LD2: Y | ENG | |
230 | LD3: Y | ENG | |
231 | LD4: Y | ENG |
Output Check Table
5804 | [OUTPUT Check] | ||
235 | Fusing Shading Plate M: Stop Pos 1(HP) | ENG | [0 or 1 / 0 / 1/step] |
Moves shade plate of fusing Md to home position. | |||
236 | Fusing Shading Plate M: Stop Pos 2(A3 3rd) | ENG | [0 or 1 / 0 / 1/step] |
Moves shade plate of fusing Md to A3 3rd position. | |||
237 | Fusing Shading Plt M: Stop Pos 3(Pstcrd 3) | ENG | [0 or 1 / 0 / 1/step] |
Moves shade plate of fusing Md to JP post card 3rd position. | |||
5804 | [OUTPUT Check] | ||
Continuously drives specified motor for operation test. | |||
241 | Bank: Tray3: Feed Mt: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
242 | Bank: Tray4: Feed Mt: Standard Speed | ENG | |
243 | Bank: Tray5: Feed Mt: Standard Speed | ENG | |
244 | Bank: Tray3: Transport Mt: Standard Speed | ENG | |
245 | Bank: Tray4: Transport Mt: Standard Speed | ENG | |
246 | Bank: Tray5: Transport Mt: Standard Speed | ENG | |
5804 | [OUTPUT Check] | ||
Drives specified motor for a certain period of time to test operation. | |||
247 | Bank: Tray3: PU Solenoid | ENG | [0 or 1 / 0 / 1/step] |
248 | Bank: Tray4: PU Solenoid | ENG |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
249 | Bank: Tray5: PU Solenoid | ENG |
6008 | [ADF OUTPUT Check] | ||
Checks operation of the load of ADF. | |||
003 | Feed Motor Forward | ENG | [0 or 1 / 0 / 1/step] |
Rotates paper feed motor forward. | |||
004 | Feed Motor Reverse | ENG | [0 or 1 / 0 / 1/step] |
Rotates paper feed motor backward. | |||
005 | Relay Motor Forward | ENG | [0 or 1 / 0 / 1/step] |
Rotates carry motor forward. | |||
006 | Relay Motor Reverse | ENG | [0 or 1 / 0 / 1/step] |
Rotates carry motor backward. | |||
011 | Inverter Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Interval drives reverse solenoid. | |||
012 | Stamp | ENG | [0 or 1 / 0 / 1/step] |
Interval drives DONE stamp. | |||
013 | Fan Motor | ENG | [0 or 1 / 0 / 1/step] |
Interval drives FAN motor. | |||
014 | Feed Clutch | ENG | [0 or 1 / 0 / 1/step] |
Interval drives paper feed clutch. | |||
015 | Feed Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Interval drives paper feed solenoid. |
Output Check Table
6012 | [1-Pass ADF OUTPUT Check] | ||
For Single-Pass simultaneous duplex models only. | |||
001 | Pick-Up Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF pick up motor. | |||
003 | Feed Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper feed motor. | |||
005 | Relay Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper carry motor. | |||
009 | Exit Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper exit motor. | |||
010 | Bottom Plate Motor For/Rev | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Moves up/down the bottom plate by driving the ADF bottom plate motor forward, backward. | |||
012 | Stamp | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Stamps the DONE stamp. |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
015 | Pull-Out Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF pull out motor. | |||
016 | Middle Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF middle motor. |
6124 | [OUTPUT Check: 2K/3K FIN] | ||
001 | Entrance Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
002 | Horizontal Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
003 | Pre-Stack Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
004 | ITB Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
005 | Paper Exit Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
006 | Upper Junction Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Turns NO/OFF specified solenoid for validation. | |||
007 | TE Stack Plate Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
008 | Paper Exit Open/Close Guide Plate Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. |
Output Check Table
009 | Punching Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
010 | Punch Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
011 | S-to-S Registration Detection Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
012 | Lower Junction Solenoid Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
013 | Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
014 | Positioning Roller Rotation Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
015 | Feed-out Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
016 | Booklet Stapler Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
017 | Corner Stapler Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
018 | Booklet Stapler Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
019 | Booklet Stapler Jog Solenoid Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
020 | Booklet Stapler Standard Fence Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
021 | Booklet Stapler Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
022 | Dynamic Roller Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
023 | Folder Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
025 | Press-fold Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
026 | Tray Lift Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
027 | Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
028 | Front Shift Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. * Not use: currently, VOLGA-B does not have setting jogger in system configuration. | |||
029 | Rear Shift Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. * Not use: currently, VOLGA-B does not have setting jogger in system configuration. | |||
030 | Shift Jogger Retraction Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. * Not use: currently, VOLGA-B does not have setting jogger in system configuration. |
Output Check Table
031 | Drag Roller Vibrating Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
032 | LE Guide Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
033 | Navigation LED (All) | ENG | [0 or 1 / 0 / 1/step] |
Lights all guide LED. |
6136 | [OUTPUT Check: FrontFIN] | ||
Continuously drives specified motor for operation test. | |||
001 | Entrance Motor | *ENG | [0 or 1 / 0 / 1/step] |
002 | Carry Motor | ENG | [0 or 1 / 0 / 1/step] |
003 | Exit Motor | ENG | [0 or 1 / 0 / 1/step] |
6136 | [OUTPUT Check: FrontFIN] | ||
Drives specified motor for a certain period of time to test operation. | |||
004 | Front Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
005 | Rear Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
006 | Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
007 | Hitroll Motor | ENG | [0 or 1 / 0 / 1/step] |
008 | Exit Guide Plate Motor | ENG | [0 or 1 / 0 / 1/step] |
009 | Staple Moving Motor | ENG | [0 or 1 / 0 / 1/step] |
010 | Tray Motor | ENG | [0 or 1 / 0 / 1/step] |
011 | Staple Motor | ENG | [0 or 1 / 0 / 1/step] |
012 | Stopper Motor | ENG | [0 or 1 / 0 / 1/step] |
013 | Punch Motor | ENG | [0 or 1 / 0 / 1/step] |
014 | Punch Moving Motor | ENG | [0 or 1 / 0 / 1/step] |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
015 | Punch Registration Moving Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Continuously runs specified motor for operation test. | |||
001 | Entrance Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
002 | Proof Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
003 | Paper Feed/Positioning & Move Roller Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Drives specified motor for a certain period of time to test operation. | |||
004 | Junction Solenoid | ENG | [0 or 1 / 0 / 1/step] |
005 | Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
006 | Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
007 | Exit Guide Plate Open/Close Motor | ENG | [0 or 1 / 0 / 1/step] |
008 | Feed-out Motor | ENG | [0 or 1 / 0 / 1/step] |
009 | Tray Lift Motor | ENG | [0 or 1 / 0 / 1/step] |
011 | Positioning Roller Motor | ENG | [0 or 1 / 0 / 1/step] |
012 | Stapler Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
013 | Stapler Motor | ENG | [0 or 1 / 0 / 1/step] |
014 | Punch Motor | ENG | [0 or 1 / 0 / 1/step] |
015 | Punch Move Motor | ENG | [0 or 1 / 0 / 1/step] |
016 | S-to-S Registration Detection Move Motor | ENG | [0 or 1 / 0 / 1/step] |
017 | Stack Transport Motor: Upper | ENG | [0 or 1 / 0 / 1/step] |
018 | Stck Trns Uppr Prss Rls/Stndrd Fence Rtrct M | ENG | [0 or 1 / 0 / 1/step] |
Output Check Table
019 | Stack Lower Pressure Release Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Continuously runs specified motor for operation test. | |||
020 | Folder Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Drives specified motor for a certain period of time to test operation. | |||
021 | TE Stopper Motor | ENG | [0 or 1 / 0 / 1/step] |
022 | Folder Blade Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Lights all guide LED. | |||
023 | Navigation LED (All) | ENG | [0 or 1 / 0 / 1/step] |
Input and Output Check
Input and Output Check
Input and Output Check
Output Check Table
6171 | [Bridge: OUTPUT Check] | ||
009 | Bridge Relay Motor: Low Speed | ENG | [0 or 1 / 0 / 1/step] |
Checks operation of the load of relay motor. Rotates forward the carry motor for 73 mm/s. | |||
010 | Bridge Relay Motor: Middle Speed | ENG | [0 or 1 / 0 / 1/step] |
Checks operation of the load of relay motor. Rotates forward the carry motor for 256 mm/s. | |||
011 | Bridge Relay Motor: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
Checks operation of the load of relay motor. Rotates forward the carry motor for 450 mm/s. | |||
012 | Junction Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Checks operation of the load of solenoid. Turns ON the solenoid. |
6173 | [Shift Tray: OUTPUT Check] | ||
001 | Shift Tray Motor | ENG | [0 or 1 / 0 / 1/step] |
Checks operation of the load of shift tray motor. Rotates forward. |
RE V IS ION H IST ORY | ||
Page | Date | Added/ Updated/ New |
None |