5.7 SERVICE CALL 620-689
5.7.1 SC600 (ENGINE: COMMUNICATION AND OTHERS)
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC620-01 | D | ADF Communication error |
After ADF connection was recognized on startup, an error is detected. (disconnection detection) | ||
SC620-02 | D | ADF Communication Error |
After ADF connection was recognized on startup, an error is detected. (Retry out due to communication error) | ||
ADF connection fault ADF defection IPU board defection Noise contamination | ||
Check the ADF cable connection Replace the ADF Replace the IPU board |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC621-00 | D | Finisher communication error |
Detected an error when connecting the communication line. Received a communication error notification from the URAT. | ||
Finisher control board defective. BCU defective IOB defective Connection fault between finisher and main machine. | ||
Reconnect the Finisher interface cable Replace the BCU Replace the finisher Turn the power off/on |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-689
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC622-00 | D | Paper bank communication error |
Detected an error when connecting the communication line. Received a communication error notification from the URAT. | ||
Paper bank control board defective BCU defective IOB defective Paper bank-main machine connection fault | ||
Reconnect the optional paper tray connection cable Replace the BCU Replace the optional paper tray Turn the power off/on |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC623-00 | D | 2nd bank communication error |
During superposition of single bank - double bank, double bank - side LICT, and LCIT - side LCIT, 1. When the upper bank side recognizes the lower bank, the break of the lower bank is not canceled within t5ms. 2. After the upper bank side recognizes the lower bank, there is no ACK within t6ms after transmission of a data frame to the lower bank, and a timeout error occurs for 3 times consecutively even if retransmission is performed (Bank/LCIT transmits "between bank 1 - bank 2: communication error" to the main machine.) | ||
Bank control board fault Connector disconnected | ||
Reset the optional paper tray connecting cable Replace the BCU Replace the optional paper tray Turn the power off/on |
Service Call 620-689
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC664 | ASIC on the IOB SRAM program expansion error | |
SC664-01 | D | Access permission error to ASIC on the IOB SRAM (write permission fails) |
SC664-02 | D | Write error to ASIC on the IOB SRAM (write result error) |
SC664-03 | D | ASIC on the IOB program startup error |
Noise Hardware defection | ||
Replace the imaging IOB and paper transport IOB Check the harness |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC665 | FFC set detection | |
FFC set error is detected by port lead and AD value read-out | ||
SC665-01 | D | BCU-IPU connection error |
SC display LED blink mode correction on BCU | ||
SC665-02 | D | BCU - imaging IOB connection error |
SC display | ||
SC665-03 | D | BCU - paper transport IOB connection error |
SC display |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC669 | EEPROM Communication Error | |
SC669-01 | D | EEPROM OPEN: ID error |
SC669-02 | D | EEPROM OPEN: Channel error |
SC669-03 | D | EEPROM OPEN: Device error |
SC669-04 | D | EEPROM OPEN: Communication abort error |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-689
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC669-05 | D | EEPROM OPEN: Communication timeout error |
SC669-06 | D | EEPROM OPEN: Operation stopped error |
SC669-07 | D | EEPROM OPEN: Buffer full |
SC669-08 | D | EEPROM OPEN: No error code |
SC669-09 | D | EEPROM CLOSE: ID error |
SC669-10 | D | EEPROM CLOSE: No error code |
SC669-11 | D | EEPROM Data write: ID error |
SC669-12 | D | EEPROM Data write: Channel error |
SC669-13 | D | EEPROM Data write: Device error |
SC669-14 | D | EEPROM Data write: Communication abort error |
SC669-15 | D | EEPROM Data write: Communication timeout error |
SC669-16 | D | EEPROM Data write: Operation stopped error |
SC669-17 | D | EEPROM Data write: Buffer full |
SC669-18 | D | EEPROM Data write: No error code |
SC669-19 | D | EEPROM Data read: ID error |
SC669-20 | D | EEPROM Data read: Channel error |
SC669-21 | D | EEPROM Data read: Device error |
SC669-22 | D | EEPROM Data read: Communication abort error |
SC669-23 | D | EEPROM Data read: Communication timeout error |
SC669-24 | D | EEPROM Data read: Operation stopped error |
SC669-25 | D | EEPROM Data read: Buffer full |
SC669-26 | D | EEPROM Data read: No error code |
SC669-27 | D | EEPROM Device detection: ID error |
SC669-28 | D | EEPROM Device detection: Channel error |
SC669-29 | D | EEPROM Device detection: Device error |
Service Call 620-689
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC669-30 | D | EEPROM Device detection: Communication abort error |
SC669-31 | D | EEPROM Device detection: Communication timeout error |
SC669-32 | D | EEPROM Device detection: Operation stopped error |
SC669-33 | D | EEPROM Device detection: Buffer full |
SC669-34 | D | EEPROM Device detection: No error code |
Electrical noise EEPROM not connected fully EEPROM not installed EEPROM damaged BCU damaged | ||
Turn the power off/on Reconnect the EEPROM Replace the EEPROM Replace the BCU |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC681- | Toner Cartridge: ID Chip Communication Error | |
01 - 04 | D | Invalid Device ID |
06 - 09 | D | Channel error |
11 - 14 | D | Device Error |
16 - 19 | D | Communication aborted (error during communication) |
21 - 24 | D | Communication timeout |
26 - 29 | D | Device stopped (logically stopped) |
31 - 34 | D | Requested buffer full |
36 - 39 | D | No error code |
When abnormality occurs at cable connection When error notification was received during communication with the tag and operation is not resumed after 3 retries. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 620-689
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
There was an error during (wired) communication with the ID chip on the toner bottle. | ||
Replace the development unit SC branch number: 01, 06, 11, 16, 21, 26, 31, 36: K 02, 07, 12, 17, 22, 27, 32, 37: M 03, 08, 13, 18, 23, 28, 33, 38: C 04, 09, 14, 19, 24, 29, 34, 39: Y |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC682- | PCU: ID Chip Communication Error | |
01 - 04 | D | Invalid Device ID |
06 - 09 | D | Channel error |
11 - 14 | D | Device Error |
16 - 19 | D | Communication aborted (error during communication) |
21 - 24 | D | Communication timeout |
26 - 29 | D | Device stopped (logically stopped) |
31 - 34 | D | Requested buffer full |
36 - 39 | D | No error code |
When error notification was received during communication with the tag and operation is not resumed after 3 retries. |
Service Call 620-689
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
HST sensor defective | ||
EEPROM defective | ||
PCU set error | ||
01 - 04 | ||
Device ID data corruption | ||
06 - 09 | ||
Connection fault (bus disconnect, etc.) | ||
11 - 14 | ||
No ID chip | ||
16 – 19, 21 – 24, 26 - 29 | ||
Noise | ||
31 - 34, 36 - 39 | ||
Software defection | ||
Replace the PCU |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
SC687-00 | D | PER Not Received Error |
Unable to receive the PER command from the controller. | ||
Communication error | ||
Replace the BCU |