1.4 GUIDANCE FOR THOSE WHO ARE FAMILIAR WITH PREDECESSOR PRODUCTS
1.4.1 DIFFERENCES FROM PREDECESSOR
Scan, LD unit, Paper feed unit
Item | D146/D147/D148/D149/D150 | Predecessor | Purpose |
Scan | LED Scanning on all models Non contact sheet-through scan (DF use) | 45/55 CPM halogen scan Contact sheet-through scan | Energy saving Improvement of black line occurrence |
LD unit | Adjustment of original point after the unit replacement Download the SP value from the unit 1 SP for coarse and fine adjustment | Adjustment of original point after the unit replacement Hand- input in reference of sheet included in the unit. 2 SP for coarse and fine adjustment | Serviceability improvement |
Paper feed | RF system Paper weight capacity:52 to 300g/m2 Draw system tray Up to SRA3 compatible (opt) Paper tray detection: Specific sensor Clicked operational feeling at position of regular paper size Double feed detection (D150 only) Small size standard support(2nd tray only) Paper dust case removable by technician | FRR system Paper weight capacity:52 to 256g/m2 Locked tray Up to A3 Paper tray detection: Paper size detection sensor No clicked operation feeling No double feed detection Small size tray option Paper dust case removable by technician | Simplify the layout Paper capability improvement User ability improvement Expand paper size User ability improvement User ability improvement Spec improvement |