HOME PAGE | < Previous | Contents | Next >

Guidance for Those Who are Familiar with Predecessor Products


Item

D146/D147/D148/D149/D150

Predecessor

Purpose


Image transfer

ITB cleaning unit position

upper of ITB unit

No lubricant in ITB cleaning unit

No bias voltage on PTR Encoder less control (FG control) of ITB Adjustment value of ID

sensor is provided by a seal attached on ID sensor


ITB cleaning unit position

left side of ITB unit lubricant in ITB cleaning unit

Bias voltage on PTR Encoder control of ITB Adjustment value of ID sensor is provided by a seal included in ID sensor


Downsizing

Cleaning ability up according to new lubricant

in PCDU


Process control

Real time process control

(when it is without SRA3 option (Imageable Area Extension Unit Type M3))

)


Normal process control


Image quality stabilization and reduction of interval time


Fusing


Item

D146/D147/D148/D149/D150

Predecessor

Purpose


Fusing sleeve material




change (Ni+Cu)

Fusing sleeve material



Two heaters + shield

(SUS: stainless)



Fusing unit replacement

Three heaters



required only at

(one is postcard purpose)

AC-TEC


SC544-02/554-02

Fusing unit replacement

reduction


occurrence

required at

Grease

Fusing

Metal single purpose grease

SC544-00/554-00/564-00/

lubulicant ability


adopted (Fluotribo) on

574-00 occurrence

up


pressure roller and the

Plastic purpose grease on

Machine layout


bushing

pressure roller and the

change


(this can be also used for the

bushing (Barrierta)



predecessors)

Pressure release motor turn



Pressure release motor turn

by both way



by one way