HOME PAGE | < Previous | Contents | Next >

PM Parts Settings


3. PREVENTIVE MAINTENANCE


3.1 PM PARTS SETTINGS


3.1.1 REPLACEMENT PROCEDURE OF THE PM PARTS

1. Enter the SP mode.

2. Output the SMC logging data with SP5-990-004.

3. Set the following SPs to "1" before you turn the power off.

Preventive Maintenance

Preventive Maintenance

Preventive Maintenance

4. Replace the PM parts and turn the power on, then, the machine will reset the PM counters automatically. In the case of developer, the developer initialization will also be done automatically.

5. Exit the SP mode.


Item

SP


PCDU

Black: 3701-002, 003

Yellow: 3701-025, 026

Cyan: 3701-048, 049

Magenta: 3701-071, 072


Development unit

Black: 3701-003

Yellow: 3701-026

Cyan: 3701-049

Magenta: 3701-072


PCU

Black: 3701-002

Yellow: 3701-025

Cyan: 3701-048

Magenta: 3701-071

Pressure Roller

(not necessary for complete fusing unit and

Heating sleeve belt unit; see below)


Pressure roller: 3701-118

Image Transfer Belt Unit

3701-093

Image Transfer Belt Cleaning Unit

3701-102

PTR Unit

3701-109