HOME PAGE | < Previous | Contents | Next >
3.1 PM PARTS SETTINGS
3.1.1 REPLACEMENT PROCEDURE OF THE PM PARTS
1. Enter the SP mode.
2. Output the SMC logging data with SP5-990-004.
3. Set the following SPs to "1" before you turn the power off.
Preventive Maintenance
Preventive Maintenance
Preventive Maintenance
4. Replace the PM parts and turn the power on, then, the machine will reset the PM counters automatically. In the case of developer, the developer initialization will also be done automatically.
5. Exit the SP mode.
Item | SP |
PCDU | Black: 3701-002, 003 Yellow: 3701-025, 026 Cyan: 3701-048, 049 Magenta: 3701-071, 072 |
Development unit | Black: 3701-003 Yellow: 3701-026 Cyan: 3701-049 Magenta: 3701-072 |
PCU | Black: 3701-002 Yellow: 3701-025 Cyan: 3701-048 Magenta: 3701-071 |
Pressure Roller (not necessary for complete fusing unit and Heating sleeve belt unit; see below) | Pressure roller: 3701-118 |
Image Transfer Belt Unit | 3701-093 |
Image Transfer Belt Cleaning Unit | 3701-102 |
PTR Unit | 3701-109 |