HOME PAGE | < Previous | Contents | Next >

Imageable Area Extension Unit Type M3


2.30 IMAGEABLE AREA EXTENSION UNIT TYPE M3


2.30.1 ACCESSORY CHECK


Description

Q’ty

Paper transfer roller (Extended)

1


2.30.2 INSTALLATION PROCEDURE


image

Do not touch the roller surface during replacement.

1. Check the Engine firmware. If the version is earlier than 1.22, then you must input all the SPs in the following table. If the version is 1.22 or later, then you only need to do SP2-400-001.


SP

Description

Default

Setting


SP2-400-001

Paper Transfer Roller Settings Width of Paper Transfer Roller


0


1

SP3-232-040

Vtref Correct:Pixel Initial ProCon Thresh

100

10

SP3-232-041

Vtref Correct:Pixel High Coverage Thresh:H

100

60

SP3-232-050

Vtref Correct:Pixel ProCon Thresh

100

50

SP3-234-011

Vtref Corr :Disp/Set Corr Amt(+):K

0

0.05

SP3-234-012

Vtref Corr :Disp/Set Corr Amt(+):C

0

0.05

SP3-234-013

Vtref Corr :Disp/Set Corr Amt(+):M

0

0.05

SP3-234-014

Vtref Corr :Disp/Set Corr Amt(+):Y

0

0.05

SP3-234-021

Vtref Corr :Disp/Set Corr Amt(-):K

0

0.05

SP3-234-022

Vtref Corr :Disp/Set Corr Amt(-):C

0

0.05

SP3-234-023

Vtref Corr :Disp/Set Corr Amt(-):M

0

0.05

SP3-234-024

Vtref Corr :Disp/Set Corr Amt(-):Y

0

0.05

SP3-533-003

Interrupt ProCon :Set Corr(Short):BW

1

0.1

Installation

Installation

Installation

Imageable Area Extension Unit Type M3


SP

Description

Default

Setting

SP3-533-013

Interrupt ProCon :Set Corr(Short):FC

1

0.25

SP3-534-001

JobEnd ProCon :Set Interval:Set:BW

500

250

SP3-534-003

JobEnd ProCon :Set Corr(Short):BW

1

0.2

SP3-534-011

JobEnd ProCon :Set Interval:Set:FC

200

100

SP3-534-013

JobEnd ProCon :Set Corr(Short):FC

1

0.5



D150: 31

D150: 25


SP1-102-024


Feed Permit Setting Temp.:Lower Delta:Press

D149: 31

D148: 22

D147: 31

D149: 25

D148: 16

D147: 26



D146: 31

D146: 26



D150: 48




or 49

D150: 42


SP1-102-025


Feed Permit Setting Temp.:Lower Delta:Press

D149: 48

or 49

D148: 39

D149: 42

D148: 33

D147: 43



D147: 48

D146: 43



D146: 48




D150: 22

D150: 19


SP1-102-031


Feed Permit Setting Temp.:Lower Delta:Press

D149: 22

D148: 16

D147: 22

D149: 19

D148: 13

D147: 19



D146: 22

D146: 19



D150: 41

D150: 36


SP1-102-032


Feed Permit Setting Temp.:Lower Delta:Press

D149: 41

D148: 35

D147: 41

D149: 36

D148: 30

D147: 36



D146: 41

D146: 36

Imageable Area Extension Unit Type M3


SP

Description

Default

Setting




D150: 20




D149: 20



D150: 5

D148: 20


SP1-117-144


Repeat Temp. Correction Temp.:End:1:SRA3:M-thick

D149: 5

D148: 5

D147: 25

D147:

25(same as Int)



D146: 25

D146:




25(same




as Int)


image

When SP2-400-001 is changed over, a message is displayed stating “Switch the power OFF/ON”.

2. After all SP values are changed, turn the power off.

3. Replace the roller.


image

[A]: Standard roller

[B]: Imageable Area Extension Unit Type M3


image

During PM replacement, do not install the wrong type of roller.

4. Turn the power on.

5. Using SRA3 paper, check that a full-bleed halftone image is output, and that the image extends to 315 mm in width.

 

When you forgot to change the SP