Waste Toner


Detailed Descriptions

Detailed Descriptions

Detailed Descriptions

bottle full sensor is first switched ON.

After the full sensor was first switched ON, the days remaining which is computed from when the sensor switched ON is displayed (upper limit is 18)

When the bottle is replaced before the machine detects a full waste toner bottle and stops printing, it is necessary to reset PM counters manually (SP3-701-142).

When the bottle is replaced after the machine stopped due to detecting a full waste toner bottle, it is not necessary to reset PM counters. If the counters are reset, the replace counter will count up twice.

SP descriptions

SP3-701-142 (Manual New Unit Set: Waste Toner Bottle)

Enables/disables the new unit detection function. When this function is ON, the machine automatically resets the PM counter when a new unit is detected.


Waste Toner Cover

The latch which existed with the previous machine has been removed for this machine.

The waste toner cover is opened by pulling the 1st paper tray, and inserting a finger into the gap (red circle) shown below.

image

The waste toner cover of the previous machine (MP C2003/C2503/C2011) is opened by pressing it with your fingers.

image