Process Control


SP Descriptions

SP2-111-001 (Forced Line Position Adj.: Mode a)

Executes MUSIC mode a ( fine-tune x 2)

SP2-111-002 (Forced Line Position Adj.: Mode b)

Executes MUSIC mode b ( fine-tune x 1)

SP2-111-003 (Forced Line Position Adj.: Mode c)

Executes MUSIC mode c (rough-tune x 1)

SP2-111-004 (Forced Line Position Adj.: Mode d)

Executes MUSIC mode d (rough-tune then fine-tune)

SP2-194-007 (MUSIC Execution Result: Execution Result)

Displays the execution results of MUSIC. 0: Completed successfully, 1: Failed

SP2-194-010,-011, and -012 (MUSIC Execution Result:Error Result: C, M, Y)

Displays the details of MUSIC results for each color.

SP3-011-001 (Manual ProCon :Exe: Normal ProCon)

Executes Pro-Con.

SP3-011-002 (Manual ProCon :Exe: Density Adjustment)

Executes toner density adjusting Pro-Con.

SP3-011-003 (Manual ProCon :Exe: ACC RunTime ProCon)

Executes pre-ACC Pro-Con.

SP3-011-004 (Manual ProCon :Exe: Full MUSIC)

Executes Pro-Con / full MUSIC.

SP3-011-005 (Manual ProCon :Exe: Normal MUSIC)

Executes Pro-Con / normal MUSIC.

SP3-012-001 to 010 (ProCon OK?: Front)

Displays the history for past 10 times of ProCon results code detected by the front TM/ID sensor. The code is 2 digits per color from left, in the order of YMCK.

SP3-012-011 to 020 (ProCon OK?: Center)

Displays the history for past 10 times of ProCon results code detected by the center TM/ID sensor. The code is 2 digits per color from left, in the order of YMCK.

SP3-012-021 to 030 (ProCon OK?: Rear)

Displays the history for past 10 times of ProCon results code detected by the rear TM/ID sensor. The code is 2 digits per color from left, in the order of YMCK.

SP3-400-001 to 004 (Toner Supply Type: Select; Bk, C, M, Y)

Selects the toner supply mode. 0: FIXED, 2: PID, 4: DANK

Process Control


Detailed Descriptions

Detailed Descriptions

Detailed Descriptions

SP3-530-001 to 008 (PowerON ProCon :Set)

Specifies the non-use time setting, temperature, relative humidity, absolute humidity or page interval as the threshold of process control execution determination at power on.

SP3-531-001 to 004 (Non-useTime Procon :Set)

Specifies the non-use time setting, temperature, relative humidity, absolute humidity or page interval as the threshold of process control execution determination for during the

stanby-mode.

SP3-533-001 (Interrupt ProCon :Set: Interval:Set:BW)

Specifies the number of sheets interval for Interrupt Pro-Con (BW).

SP3-533-002 (Interrupt ProCon :Set: Interval:Disp:BW)

Displays the number of sheets interval for Interrupt Pro-Con (BW).

SP3-533-003 (Interrupt ProCon :Set: Corr(Short):BW)

Specifies the correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (BW).

SP3-533-004 (Interrupt ProCon :Set: Corr(Mid):BW)

Specifies the correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (BW).

SP3-533-011 (Interrupt ProCon :Set: Interval:Set:FC)

Specifies the number of sheets interval for Interrupt Pro-Con (FC).

SP3-533-012 (Interrupt ProCon :Set: nterval:Disp:FC)

Displays the number of sheets interval for Interrupt Pro-Con (FC).

SP3-533-013 (Interrupt ProCon :Set: Corr(Short):FC)

Specifies the correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (FC).

SP3-533-014 (Interrupt ProCon :Set: Corr(Mid):FC)

Specifies the correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (FC).

SP3-534-001 (JobEnd ProCon :Set: Interval:Set:BW)

Specifies the number of sheets interval for Job end Pro-Con (BW).

SP3-534-002 (JobEnd ProCon :Set: Interval:Disp:BW)

Displays the number of sheets interval for Job end Pro-Con (BW).

SP3-534-003 (JobEnd ProCon :Set: Corr(Short):BW)

Specifies the correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (BW).

SP3-534-004 (JobEnd ProCon :Set: Corr(Mid):BW)

Specifies the correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (BW).

SP3-534-011 (JobEnd ProCon :Set: Interval:Set:FC)

Specifies the number of sheets interval for Job end Pro-Con (FC).

Process Control


SP3-534-012 (JobEnd ProCon :Set: Interval:Disp:FC)

Displays the number of sheets interval for Job end Pro-Con (FC).

SP3-534-013 (JobEnd ProCon :Set: Corr(Short):FC)

Specifies the correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (FC).

SP3-534-014 (JobEnd ProCon :Set: Corr(Mid):FC)

Specifies the correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (BW).

SP3-539-001 (Dev Agitating Time :Set: Time) Specifies the developer agitating time.

SP3-600-002 (Select ProCon: LD Control)

Specifies the LD control mode. 0:OFF, 1:ON

SP3-600-030 (Select ProCon: IBACC:ON/OFF)

Specifies ON/OFF of IBACC. 0: OFF, 1: ON