Process Control | Operative Condition | Related SPs | |
3 | Interrupt ProCon :Set | When the value of the job interrupt counter becomes more than the threshold | SP3-533-001 to 004 SP3-533-011 to 014 |
4 | Non-useTime Procon :Set | When the value of the non-use time counter becomes more than the threshold | SP3-531-001 to 004 |
5 | Manual ProCon :Exe | When SP 3-011 is used | SP3-011-001 to 005 |
6 | Toner End Recovery | After the Toner End Status is cleared (Recovery is NOT done in the near end status) | - |
7 | Initial Developer Setting Process Control | When the machine detects a new PCU or development unit | - |
Result Code for Executing Process Control
Check the following SPs.
SP3-012-001 to 010 (Front)
SP3-012-011 to 020 (Center)
SP3-012-021 to 030 (Rear)
Category | Code | Result name | Description |
00 and larger | 00 | Not executed | Factory default setting (SP default) |
10 and larger Result (Normal) | 11 | Succeeded | - |
40 and larger ID Sensor | 41 | ID sensor output error (Max) | Vt > Max |
42 | ID sensor output error (Min) | Vt < Min |
Process Control
Category | Code | Result name | Description |
43 | ID Sensor error (Max) | Development gamma is in target, but Vt value is less than upper limit. | |
44 | ID Sensor error (Min) | Development gamma is in target, but Vt value is less than lower limit. | |
45 and larger ID Pattern detection | 45 | ID Pattern extract error | Cannot detect ID Pattern |
50 | Vmin_Bk/K2 error (Max) | K:Vmin_Bk / CMY:K2 > Max | |
51 | Vmin_Bk/K2 error (Min) | K:Vmin_Bk / CMY:K2 < Min | |
52 | K5 error (Max) | K5 > Max | |
53 | K5 error (Min) | K5 < Min | |
54 | K5 calculated approximate point error | K5 calculated approximate point < Min | |
55 | Development gamma error (Max) | Development gamma > Max | |
56 | Development gamma error (Min) | Development gamma < Min | |
57 | Start developing voltage: Vk error(Max) | Start developing voltage: Vk > Max | |
58 | Start developing voltage: Vk error(Min) | Start developing voltage: Vk < Min | |
59 | Not enough valid data | Adhesion amount data for development gamma calculation point is under 2. | |
90 and larger Result(End) | 90 | Potential not adjusted | Potential control method is set as [0:FIX]. |
99 | Stopped | Stopped by door open, power off, error. (Set when execute.) |