Anti-Condensation Heater for Paper Feed Trays


Installation

Installation

Installation

2.4.4 CONNECTING TO PAPER FEED UNIT PB3150

1. Perform Steps 1 to 7 of page 2-59 "Connecting to Main Machine Tray".

2. Pull out the paper feed tray of PB3150.

3. Put the harness of the heater [A] for the optional paper feed unit through the hole at the inner rear frame, and then attach it imagex1).

image

4. Remove the securing brackets [A] of Paper Feed Unit PB3150.


image

5. Remove the rear cover [A] of Paper Feed Unit PB3150.


image

Anti-Condensation Heater for Paper Feed Trays


6. Remove the bracket [A] on the bottom of the main unit imagex1).

The removed bracket can be discarded.


image

7. Connect the PFU harness [A] of the optional paper feed unit to the relay harness [B] of the main unit and the heater harness [C] image x4).

image

8. Reinstall the removed parts and covers.

9. Connect the power supply cord and turn ON the main power.

Do the following two steps to set the anti-condensation heater to be constantly ON.

1. Set the setting of SP5-805-001 (Anti-Condensation Heater ON/OFF setting) to [1].

2. Manually disconnect the PCU and scanner heaters.


The PCU and scanner heaters must be disabled because the temperature in the machine could become too high, causing problems with toner clogging, or damage to the scanner lamp stabilizer