HOME PAGE | < Previous | Contents | Next >
Guidance for Those Who are Familiar with Predecessor Products
Detailed Descriptions
Detailed Descriptions
Detailed Descriptions
Electrical Parts
Items | MP C2003/C2503 /C2011 | MP C6004/C5504/C4504 /C3504/C3004 | MP C2004/C2504 |
SIO | Available | Not available The functions for this old board are included on the IPU | |
Human detection (Proximity sensor) | Not Available | Available Equipped with the proximity sensor (human detection sensor). | |
OPU | 1st generation Smart Operation Panel | 2nd generation Smart Operation Panel |
Exterior Cover / Air Flows (Fan Control)
Items | MP C2003/C2503 /C2011 | MP C6004/C5504/C4504 /C3504/C3004 | MP C2004/C2504 |
Air flow | 8 fans | MP C6004/C5504/C4504: 10 fans MP C3004/C3504: 7 fans | 7 fans |
Duct | - | Increased the rigidity of the duct Changed the duct shape | |
Noise control | - | Equipped with a Helmholtz silencer Labyrinth structure of the exterior |
Labyrinth structure of the exterior:
Exterior parts engage with each other to reduce the leaking of the driving noise.