HOME PAGE | < Previous | Contents | Next >
Guidance for Those Who are Familiar with Predecessor Products
Detailed Descriptions
Detailed Descriptions
Detailed Descriptions
Laser Exposure
Items | MP C2003/C2503 /C2011 | MP C6004/C5504/C4504 /C3504/C3004 | MP C2004/C2504 |
Laser unit | LD 1 beam | MPC4504/C5504/C6004: LD 4 beams MP C3004/C3504: LD 1 beam | LD 1 beam |
PCDU (Photo Conductor and Development Unit)
Items | MP C2003/C2503 /C2011 | MP C6004/C5504/C4504 /C3504/C3004 | MP C2004/C2504 |
MPC4504/C5504/C6004: | |||
The seals for all colors | |||
Removal of PCDU seal | The seals must be pulled out for all colors. | must be wound up. MP C3004/C3504: The seal for K must be wound up with a special | The seals must be pulled out for all colors. |
tool, and the seals for | |||
CMY must be pulled out | |||
PCU | DC charge roller (Contact type) Correction SP value must be input when PCU is replaced No lubricant bar Discharge lamp is in the main frame | AC charge roller (No contact type) Lubricant bar No discharge lamp | DC charge roller (Contact type) Correction SP value must be input when PCU is replaced No lubricant bar Discharge lamp is in the main frame |