HOME PAGE | < Previous | Contents | Next >

Troubleshooting for SC Errors


Troubleshooting

Troubleshooting

Troubleshooting

4. Replace PSU


6.12.7 WHEN SC672 (CONTROLLER START UP ERROR) IS DISPLAYED

Symptom

Note: CTL = Controller The following occur:



SC672-00

Communication error between operation panel and CTL after machine is powered on.


SC672-10

Communication error (receive) between operation panel and CTL after machine is powered on.


SC672-11

Communication error (send) between operation panel and CTL after machine is powered on.


SC672-12

Communication error between operation panel and CTL after normal start-up.


SC672-13

Communication error between operation panel and CTL after normal start-up; Operation panel not detected.


SC672 does not appear on the SMC report, as it is not logged.

The Smart Operation Panel communicates with the controller via a USB cable and IPU. SC672 is triggered when the panel cannot communicate with the controller.


Causes

Possible causes of SC672 include:

USB communication path failure (USB cable, IPU)

CTL boot up error and/or operation panel boot up error due to abnormal break in operations of CTL.

Possible causes of operation panel cannot light include:

USB communication path failure (USB cable, IPU)

Operation panel cannot communicate with CTL due to CTL boot-up error