Service Call 900-998


6.11.2 SC900 (CONTROLLER)


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC900-00

A

Electric counter error

The electric total counter value is out of specification. Error is detected when increasing the total counter.

Unexpected NV-RAM is attached.

NV-RAM defective

NV-RAM data corrupted.

Data written to unexpected area because of external factor etc.

The count requested by the SRM on receiving PRT is not completed.

Replace the NV-RAM.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC910-01

C

External controller error 1

SC910-02

C

External controller error 2

SC910-03

C

External controller error 3



-01

The external controller receives the unexpected command from

the engine side.

-02

The external controller wrongly receives the command from the

engine side.

-03

The external controller receives the engine status out of

specification.

Refer to the instructions for the external controller

Turn the main power OFF/ON.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 900-998


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC910-10

C

External controller error 1

The external controller error is detected due to other reason shown in SC910-01 to -03.

Refer to the instructions for the external controller

Turn the main power OFF/ON.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC919-00

D

External controller down

While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, of BREAK signal from the other station was detected.

External controller and the machine had been operating correctly (*) but the external controller was turned off or rebooted, or the video bus was disconnected.

* Printing or scanning using the external controller.

Turn the main power OFF/ON.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC920-02

B

Printer application error (WORK memory cannot be acquired)

SC920-04

B

Printer application error (Filter process ended abnormally)



An error was detected in the application, and no further operation is possible.

There is a bug in the software.

The hardware configuration is not as planned (for example, insufficient memory).

Turn the main power OFF/ON.

Increase the memory storage capacity.

Service Call 900-998


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC921-00

B

Printer application error (Resident font not found)

The resident fonts cannot be found at printer startup.

The resident font file is missing.

Turn the main power off/on.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC925-00

B

NetFile function error

SC925-01

B

NetFile function error



The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue.

HDD defective

HDD inconsistency caused by power failure during HDD access, etc.

Software bug

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 900-998


SC No.

Type

Error Name/Error Condition/Major Cause/Solution



If another SC related to HDD errors (SC860 to SC865) is issued at the same time, the HDD is the cause. Solve the other SC.

If SC860 to SC865 is not issued

Turn the main power off/on.

If this does not work, initialize the HDD NetFile partition (SP5-832-011: HDD Formatting (Ridoc I/F)). Approval by the customer is required because received fax message waiting to be delivered and documents waiting to be captured will be lost.

Procedure:

1. Go into the User Tools mode and do "Delivery Settings" to print all received fax documents that are scheduled for delivery. Then erase them.

2. In the User Tools mode, do Document Management> Batch Delete Transfer Documents.

3. Do SP5-832-011, then turn the machine power off and on.

If this does not solve the problem, initialize all partitions of the HDD (SP5-832-001: HDD Formatting (ALL)), then turn the machine power off and on.

Approval by the customer is required because documents and Address Book information in the HDD will be lost.

Received fax messages stored are protected but the order may be changed.

If this does not solve the problem, replace the HDD.

Service Call 900-998



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC990-00

D

Software operation error

Software attempted an unexpected operation.

Parameter error

Internal parameter error

Insufficient work memory

Operation error caused by abnormalities that are normally undetectable.

Turn the main power off/on.

Reinstall the software of the controller and BCU board.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC991-00

C

Recoverable software operation error

Software attempted an unexpected operation.

SC991 covers recoverable errors as opposed toCS990.

Parameter error

Internal parameter error

Insufficient work memory

Operation error caused by abnormalities that are normally undetectable.

Logging only



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC992-00

D

Undefined SC issued.

An SC, that is not controlled by the system, occurred.

An SC for the previous model was used mistakenly, etc.

Basically a software bug.

Turn the main power OFF/ON.

Troubleshooting

Troubleshooting

Troubleshooting

Service Call 900-998


SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC994-00

C

Operation error caused by abnormalities that are normally undetectable.

An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware.

This can occur if there are too many application screens open on the operation panel.

Logging only.



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC997-00

D

Application function selection error

The application selected by the operation panel key operated abnormally (No response, abnormal ending).

Software bug (mainly the application)

Check the optional RAM, DIMM, boards required by the application program.

Check if the combination of downloaded programs are correct.

Service Call 900-998



SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC998-00

D

Application start error

No application was registered to system within a specified time after the main power was turned on.

(No application starts/All applications have been terminated abnormally)

Application started but cannot be drawn now for some reason.

Software bug (mainly the application)

The optional RAM, DIMM, boards required by the application program. Are not installed correctly.

Turn the main power OFF/ON.

Check the optional RAM, DIMM, boards

Check the combination of programs

Replace the controller board.