HOME PAGE | < Previous | Contents | Next >
6.11.2 SC900 (CONTROLLER)
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC900-00 | A | Electric counter error |
The electric total counter value is out of specification. Error is detected when increasing the total counter. | ||
Unexpected NV-RAM is attached. NV-RAM defective NV-RAM data corrupted. Data written to unexpected area because of external factor etc. The count requested by the SRM on receiving PRT is not completed. | ||
Replace the NV-RAM. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC910-01 | C | External controller error 1 |
SC910-02 | C | External controller error 2 |
SC910-03 | C | External controller error 3 |
-01 | ||
The external controller receives the unexpected command from | ||
the engine side. | ||
-02 | ||
The external controller wrongly receives the command from the | ||
engine side. | ||
-03 | ||
The external controller receives the engine status out of | ||
specification. | ||
Refer to the instructions for the external controller | ||
Turn the main power OFF/ON. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 900-998
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC910-10 | C | External controller error 1 |
The external controller error is detected due to other reason shown in SC910-01 to -03. | ||
Refer to the instructions for the external controller | ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC919-00 | D | External controller down |
While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, of BREAK signal from the other station was detected. | ||
External controller and the machine had been operating correctly (*) but the external controller was turned off or rebooted, or the video bus was disconnected. * Printing or scanning using the external controller. | ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC920-02 | B | Printer application error (WORK memory cannot be acquired) |
SC920-04 | B | Printer application error (Filter process ended abnormally) |
An error was detected in the application, and no further operation is possible. | ||
There is a bug in the software. The hardware configuration is not as planned (for example, insufficient memory). | ||
Turn the main power OFF/ON. Increase the memory storage capacity. |
Service Call 900-998
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC921-00 | B | Printer application error (Resident font not found) |
The resident fonts cannot be found at printer startup. | ||
The resident font file is missing. | ||
Turn the main power off/on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC925-00 | B | NetFile function error |
SC925-01 | B | NetFile function error |
The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue. | ||
HDD defective HDD inconsistency caused by power failure during HDD access, etc. Software bug |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 900-998
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
If another SC related to HDD errors (SC860 to SC865) is issued at the same time, the HDD is the cause. Solve the other SC. If SC860 to SC865 is not issued Turn the main power off/on. If this does not work, initialize the HDD NetFile partition (SP5-832-011: HDD Formatting (Ridoc I/F)). Approval by the customer is required because received fax message waiting to be delivered and documents waiting to be captured will be lost. Procedure: 1. Go into the User Tools mode and do "Delivery Settings" to print all received fax documents that are scheduled for delivery. Then erase them. 2. In the User Tools mode, do Document Management> Batch Delete Transfer Documents. 3. Do SP5-832-011, then turn the machine power off and on. If this does not solve the problem, initialize all partitions of the HDD (SP5-832-001: HDD Formatting (ALL)), then turn the machine power off and on. Approval by the customer is required because documents and Address Book information in the HDD will be lost. Received fax messages stored are protected but the order may be changed. If this does not solve the problem, replace the HDD. |
Service Call 900-998
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC990-00 | D | Software operation error |
Software attempted an unexpected operation. | ||
Parameter error Internal parameter error Insufficient work memory Operation error caused by abnormalities that are normally undetectable. | ||
Turn the main power off/on. Reinstall the software of the controller and BCU board. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC991-00 | C | Recoverable software operation error |
Software attempted an unexpected operation. SC991 covers recoverable errors as opposed toCS990. | ||
Parameter error Internal parameter error Insufficient work memory Operation error caused by abnormalities that are normally undetectable. | ||
Logging only |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC992-00 | D | Undefined SC issued. |
An SC, that is not controlled by the system, occurred. | ||
An SC for the previous model was used mistakenly, etc. Basically a software bug. | ||
Turn the main power OFF/ON. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 900-998
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC994-00 | C | Operation error caused by abnormalities that are normally undetectable. |
An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. | ||
This can occur if there are too many application screens open on the operation panel. | ||
Logging only. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC997-00 | D | Application function selection error |
The application selected by the operation panel key operated abnormally (No response, abnormal ending). | ||
Software bug (mainly the application) | ||
Check the optional RAM, DIMM, boards required by the application program. Check if the combination of downloaded programs are correct. |
Service Call 900-998
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC998-00 | D | Application start error |
No application was registered to system within a specified time after the main power was turned on. (No application starts/All applications have been terminated abnormally) Application started but cannot be drawn now for some reason. | ||
Software bug (mainly the application) The optional RAM, DIMM, boards required by the application program. Are not installed correctly. | ||
Turn the main power OFF/ON. Check the optional RAM, DIMM, boards Check the combination of programs Replace the controller board. |