HOME PAGE | < Previous | Contents | Next >
Troubleshooting
Troubleshooting
Troubleshooting
6.10 SERVICE CALL 816-899
6.10.1 SC800 (CONTROLLER)
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC816-** | [0x0000] | Energy save I/O subsystem error |
SC816-01 | D | Subsystem error |
SC816-02 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-03 | D | Transition to STR was denied. |
SC816-04 | D | Interrupt in kernel communication driver |
SC816-05, 06 | D | Preparation for transition to STR failed. |
SC816-07 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-08 | D | Sysarch (LPUX_ENGINE_TIMERCTRL) error |
SC816-09 | D | Sysarch (LPUX_RETURN_FACTOR_STR) error |
SC816-10 to 12 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-13 | D | open() error |
SC816-14 | D | Memory address error |
SC816-15 to 18 | D | open() error |
SC816-19 | D | Double open() error |
SC816-20 | D | open() error |
SC816-22 | D | Parameter error |
SC816-23, 24 | D | read() error |
SC816-25 | D | write () error |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC816-26 to 28 | D | write() communication retry error |
SC816-29, 30 | D | read() communication retry error |
SC816-35 | D | read() error |
SC816-36 to 96, 99 | D | Subsystem error |
Energy save I/O subsystem detected some abnormality. | ||
Energy save I/O subsystem defective Energy save I/O subsystem detected a controller board error (non-response). Error was detected during preparation for transition to STR. SC816-99 occurs as a subsystem error except any error from -06 to 96. | ||
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step. 1. Update the "System/Copy" firmware and the other system firmware modules to the latest version. 2. Disable the STR shift function by SP5-191-001 (Power Str Set). 3. Replace the controller board. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC817-00 | D | Monitor error: File detection / Digital signature error |
Bootloader cannot read any of diagnostic module, kernel, or root filesystem. In a bootloader SD card, the digital signature checking for any of diagnostic module, kernel, or root filesystem is failed. | ||
Any of the following items does not exist or is broken OS Flash ROM, Diagnostic module in SD card, Kernel, Root filesystem Any of the following items is revised fraudulently: Diagnostic module in SD card, Kernel, Root filesystem | ||
ROM update for controller system Use another booting SD card having a valid digital signature |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC818-00 | D | Watchdog timer error |
The system program fell into a bus-hold state or an endless loop of the program interruption occurred, causing other process to stop. | ||
System program defective Controller board defective Optional board defective | ||
Turn the main power OFF/ON. Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC819-00 | D | Kernel halt error [xxxx]: Detailed error code |
Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
[0x5032] | HAIC-P2 error | |
HAIC-P2 decompression error (An error occurred in the ASIC compression/decompression module.) | ||
The code data saved in the HDD was broken for an unexpected reason. (HDD device defective) The code data saved to memory was broken for an unexpected reason. (Memory device defective) ASIC defective Data other than code data was unzipped due to a software malfunction. | ||
Turn the main power OFF/ON. Replace the HDD. Replace the memory Replace the controller board. Fix the software | ||
[0x5245] | Link up error | |
Link up transaction between Engine ASIC and Veena was not completed within 100 ms. | ||
Either one of following message appears on console if Link up error occurs. RESUME:PCI-Express bus ROOT_DL status error RESUME:PCI-Express bus DETUP status error "0x53554D45" -> Link up error Also, error code "0x5245" and detail code ""0x53554D45" -> Link up error" appears on operation panel. | ||
Turn the main power OFF/ON. Replace the controller board or the engine board (IPU, BCU) | ||
[0x5355] | L2 status time out | |
L2 status register between Engine ASIC and Veena was not reached the target value within 1 sec. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
Engine ASIC during operation was rebooted or shifted to energy saving mode. Machine reboots when SC23x, SC30x occurs. If Engine ASIC is working when rebooting (or shifting to the energy saving mode), L2 status value is not on target. The following message appears on console. SUSPEND:PCI-Express L2 Status Check Error SUSPEND:PCI-Express L2 Status Check Error Also, error code "0x5355" and detail code ""0x5350454E44" -> L2 status time out" appears on operation panel. | ||
Turn the main power OFF/ON. Replace the controller board or the engine board (IPU, BCU) | ||
[0x6261] | HDD defective | |
Received file system data was broken even if the initialization succeeds and there was no error reply from the HDD. | ||
Power supply disconnection during data writing to the HDD. | ||
Replace the HDD. This SC may occur when turning on the machine for the first time with a new HDD. In this case, turn the main power off/on. | ||
[0x696e] | gwinit processing end | |
If the SCS process is ended for some reason | ||
If an unexpected error occurs at SCS processing end, gwint processing also halts (this result is judged a kernel stop error, by gwinit specification) "0x69742064" -> "init died" | ||
Turn the main power OFF/ON. | ||
[0x766d] | VM full error | |
Occurs when too much RAM is used during system processing | ||
"vm_pageout: VM is full" | ||
Turn the main power OFF/ON. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
Console string | Other error (characters on operation panel) | |
System detected internal mismatch error | ||
Software defective Insufficient memory Hardware driver defective (RAM, flash memory) | ||
Replace with a larger capacity RAM, or flash memory. Replace the controller board. Replace the connected controller option with a new one. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC820-00 | C | Self-diagnostics error: CPU [XXXX]: Detailed error code |
[0612] | ASIC interrupt error | |
Interrupt occurs in an ASIC. | ||
ASIC device error Peripherals device error | ||
Replace the controller board Replace the connected controller option with a new one. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC821-00 | D | Self-diagnostics error: ASIC [xxxx]: Detailed error code |
[0B00] | ASIC register check error | |
The write-&-verify check has occurred in the ASIC. | ||
Defective ASIC device | ||
Replace the controller board. | ||
[0B06] | ASIC detection error | |
Error in the I/O ASIC for system control detection |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
Defective ASIC Defective North Bridge and PCII/F | ||
Replace the controller board. | ||
[0D05] | Comparison error of CPU and ASIC timer | |
The CPU checks if the ASIC timer works correctly compared with the CPU timer. If the ASIC timer does not function in the specified range, this SC code is displayed. | ||
Defective ASIC timer device Defective CPU device | ||
Replace the controller board. | ||
[50A1] | Video bridge device detection error | |
Video bridge device is not detected. | ||
Video bridge device ASIC (HARP or KLAVIER) defective. Connection error between PCI I / F of the controller ASIC and video bridge device ASIC. | ||
Replace the controller board | ||
[50A2] | Video bridge device (ASIC) register error | |
The CPU detects the video bridge device, but detects error data from the video bridge device. | ||
Defective I/F between the video bridge device and the controller | ||
Replace the controller board. |
Service Call 816-899
No. | Type | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
SC822-00 | D | Self-diagnostic error: HDD [xxxx]: Detailed error code |
[3003] | HDD timeout | |
Check performed only when HDD is installed: HDD device busy for over 31sec. After a diagnostic command is set for the HDD, but the device remains busy for over 6sec. | ||
HDD defective HDD harness disconnected, defective Controller board defective | ||
Replace the HDD. Replace the HDD connector. Replace the controller board. | ||
[3004] | Diagnostic command error | |
No response to the self-diagnostic command from the ASIC to the HDD. | ||
HDD defective | ||
Replace the HDD. | ||
[3013] | HDD timeout (first machine) | |
HDD device busy for over 31 seconds. A diagnostic command is set for the HDD, but the device remains busy for over 6 seconds. | ||
Defective HDD device Defective HDD connector Defective ASIC device | ||
Replace or remove the HDD device. Replace the HDD connector Replace the controller board |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Details (Symptom, Possible Cause, Troubleshooting Procedures) |
[3014] | Diagnostics command error (First machine) | |
Result of the issuance of diagnostic command is error. | ||
Defective HDD device | ||
Replace the HDD device. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC823-00 | B | Self-diagnostics error: NIC [XXXX]: Detailed error code |
[6101] | MAC address check sum error | |
The result of the MAC address check sum does not match the check sum stored in ROM. | ||
Defective SEEP ROM Defective I2C bus (connection) | ||
Replace the controller board. | ||
[6104] | PHY IC error | |
The PHY IC on the controller cannot be correctly recognized. | ||
Defective PHY chip Defective ASIC MII I/F | ||
Replace the controller board. | ||
[6105] | PHY IC loop-back error | |
An error occurred during the loop-back test for the PHY IC on the controller. | ||
PHY chip Defective MAC of ASIC (SIMAC/COMIC/CELLO) Defective I/F with the PHY board Defective solder on the PHY board | ||
Replace the controller board. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC824-00 | C | Self-diagnostics error: NVRAM (resident) [XXXX]: Detailed error code |
[1401] | NVRAM verify error | |
NVRAM device is missing or NVRAM device is damaged. | ||
The NVRAM device is missing. The NVRAM device is damaged. NVRAM backup battery exhausted NVRAM socket damaged | ||
Replace the NVRAM device. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC833-00 | D | Self-diagnostic error: Engine I/F ASIC [XXXX]: Detailed error code |
[0F30] | Engine I/F ASIC detection error | |
ASIC (Mandolin) for engine control could not be detected. | ||
ASIC (Mandolin) error | ||
Replace the Engine I/F board (mother board). | ||
[50B1] | Video device: clock generator detection error | |
Could not initialize or read the bus connection. | ||
Defective connection bus Defective SSCG | ||
Replace the Engine I/F board (mother board). | ||
[50B2] | Video device: clock generator verify error | |
Value of the SSCG register is incorrect. | ||
Defective connection bus Defective SSCG | ||
Replace the Engine I/F board (mother board). |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC834-00 | D | Self-diagnostic error: Optional memory |
[5101] | Engine I/F optional memory verify error | |
An error occurs after write/verify check for optional RAM on the engine I/F board (mother board). | ||
Defective memory device | ||
Replace the Engine I/F board (mother board). |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC835-00 | B | Self-diagnostic error: Centronic device [xxxx]: Detailed error code |
[1102] | Verify error | |
The loopback connector is connected but check results is an error. | ||
IEEE1284 connector error Centronic loopback connector defective | ||
Replace the controller board. | ||
[110C] | DMA verify error | |
The loopback connector is connected but check results is an error. | ||
ASIC device error IEEE1284 connector error Centronic loopback connector is defective | ||
Replace the controller board. | ||
[1120] | Loopback connector not detected | |
Centronic loopback connector is not connected for detailed self-diagnostic test. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
Centronic loopback connector not connected correctly Centronic loopback connector is defective ASIC device is defective | ||
Connect the centronic loopback connector Replace the centronic loopback connector Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC838-00 | C | Self-diagnostic Error: Clock Generator [xxxx]: Detailed error code |
[2701] | Verify error | |
A verify error occurred when setting data was read from the clock generator via the I2C bus. | ||
Defective clock generator Defective I2C bus Defective I2C port on the CPU | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC839-00 | D | Self-diagnostic Error: Serial Flash [xxxx]: Detailed error code |
[9001] | Serial Flash access error | |
USB NAND Flash ROM cannot be read. | ||
Defective controller board | ||
Replace the controller board. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC840-00 | D | EEPROM access error |
During the I/O processing, a reading error occurred. The 3rd reading failure causes this SC code. During the I/O processing, a writing error occurred. | ||
Defective EEPROM | ||
- |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC841-00 | D | EEPROM read data error |
Mirrored data of the EEPROM is different from the original data in EEPROM. | ||
Data in the EEPROM is overwritten for some reason. | ||
- |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC842-00 | C | Nand-Flash updating verification error |
SCS write error (verify error) occurred at the Nand-Flash module when remote ROM or main ROM was updated. | ||
Nand-Flash defective | ||
Turn the main power OFF/ON. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC842-01 | C | Insufficient Nand-Flash blocks (threshold exceeded) |
At startup, or when machine returned from low power mode, the Nand-Flash status was read and judged that the number of unusable blocks had exceeded threshold, and then SCS generated the SC code. | ||
Number of unusable blocks exceeded threshold for Nand-Flash | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC842-02 | C | Number of Nand-Flash block deletions exceeded |
At startup, or when the machined returned from low power mode, the Nand-Flash was read and judged that the number of deleted blocks had exceeded threshold, and then SCS generated this SC code. | ||
Number of blocks deleted exceeded threshold for Nand-Flash | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC845 | Hardware Error Detected when the automatic firmware update | |
SC845-01 | D | Engine Board |
SC845-02 | D | Controller Board |
SC845-03 | D | Operation Panel (Normal) |
SC845-04 | D | Operation Panel (Smart Panel) |
SC845-05 | D | FCU |
When updating the firmware automatically (ARFU), the firmware cannot be read or written normally, and the firmware update cannot be completed even by 3 retries. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
Hardware abnormality of the target board | ||
Replacing the target board For SC845-02, HDD and memory may cause the problem. Replace the HDD or memory if the SC cannot be recovered by replacing the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC853-00 | B | Bluetooth device connection error |
The Bluetooth hardware (USB type) was connected after the machine was turned on. | ||
The Bluetooth hardware (USB type) was connected after the machine was turned on. | ||
Always connect the Bluetooth device (USB type) before the machine is turned on. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC854-00 | B | Bluetooth device disconnected |
The Bluetooth hardware (USB type) was disconnected after the machine was turned on. | ||
The Bluetooth hardware (USB type) was disconnected after the machine was turned on. | ||
Never remove Bluetooth (USB type) after machine starts |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC855-01 | B | Wireless LAN board error (driver attachment failure) |
Wireless LAN board error (wireless LAN card: 802.11 is covered) | ||
Defective wireless LAN board Loose connection | ||
Turn the main power OFF/ON. Replace wireless LAN board |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC855-02 | B | Wireless LAN board error (driver initialization failure) |
Wireless LAN board error (wireless LAN card: 802.11 is covered) | ||
Defective wireless LAN board Loose connection | ||
Turn the main power OFF/ON. Replace wireless LAN board |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC857-00 | B | USB I/F Error |
The USB interface is unusable because of a driver error. | ||
USB driver error (There are three causes of USB error: RX error/CRC error/STALL. SC is issued only in the case of STALL.) | ||
Check USB connection. Replace the controller board. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC858-00 | A | Data encryption conversion error (Key Setting Error) |
A serious error occurred during an attempt to update the encryption key. | ||
USB Flash, other data, corrupted Communication error caused by electrostatic noise Controller board defective | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC858-01 | A | Data encryption conversion error (HDD Key Setting Error) |
A serious error occurred during an attempt to update the encryption key. | ||
USB Flash, other data, corrupted Communication error caused by electrostatic noise Controller board defective | ||
Turn the main power OFF/ON. If the error persists, replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC858-02 | A | Data encryption conversion error (NVRAM Read/Write Error) |
A serious error occurred after data conversion during an attempt to update the encryption key. | ||
NVRAM defective | ||
Replace the NVRAM. Replace the controller board. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC858-30 | A | Data encryption conversion error (NVRAM Before Replace Error) |
A serious error occurred after data conversion during an attempt to update the encryption key. | ||
Software error such as conversion parameters being invalid. | ||
Turn the main power OFF/ON. If the error persists, replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC858-31 | A | Data encryption conversion error (Other Error) |
A serious error occurred after data conversion during an attempt to update the encryption key. | ||
Controller board defective | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC859-00 | B | Data encryption conversion HDD conversion error |
When the data encryption key was updated, HDD data was converted, but not correctly. Image displayed at conversion only (this SC is not displayed), but SC is displayed after machine is cycled off/on. | ||
HDD conversion was set with the data encryption key update function, but the HDD was removed. Machine lost power during data encryption key update Electrostatic noise, or an HDD error occurred, during data encryption key update, and data was not encrypted. | ||
Check HDD connection. Format the HDD (SP5-832: HDD formatting). If there is a problem with the HDD, it has to be replaced. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC859-01 | B | Data encryption conversion HDD conversion error (HDD check error) |
When the data encryption key was updated, HDD data was converted, but not correctly. Image displayed at conversion only (this SC is not displayed), but SC is displayed after machine is cycled off/on. | ||
HDD conversion was set with the data encryption key update function, but the HDD was removed. Machine lost power during data encryption key update Electrostatic noise, or an HDD error occurred, during data encryption key update, and data was not encrypted. | ||
Check HDD connection. Format the HDD (SP5-832: HDD formatting). If there is a problem with the HDD, it has to be replaced. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC859-02 | B | Data encryption conversion HDD conversion error (Power failure during conversion) |
When the data encryption key was updated, HDD data was converted, but not correctly. Image displayed at conversion only (this SC is not displayed), but SC is displayed after machine is cycled off/on. Details: NVRAM/HDD conversion is incomplete. | ||
Power failure occurred during encryption key update. | ||
None The display after restart instructs the user to format the HDD. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC859-10 | B | Data encryption conversion HDD conversion error (Data read/write command error) |
When the data encryption key was updated, HDD data was converted, but not correctly. Image displayed at conversion only (this SC is not displayed), but SC is displayed after machine is cycled off/on. Details: Abnormal DMAC return value has been received two or more times (DMAC timeout, serial communication error etc.) | ||
HDD was not successfully converted during encryption key update due to HDD errors or cable noises. | ||
Check HDD connection. Format the HDD (SP5-832: HDD formatting). If there is a problem with the HDD, it has to be replaced. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC860-00 | B | HDD startup error at main power on (HDD error) |
The HDD is connected but the driver detected the following errors. SS_NO.T_READY:/* (-2)HDD does not become READY*/ SS_BAD_LABEL:/* (-4)Wrong partition type*/ SS_READ_ERROR:/* (-5)Error occurred while reading or checking the label*/ SS_WRITE_ERROR:/* (-6)Error occurred while writing or checking the label*/ SS_FS_ERROR:/* (-7)Failed to repair the filesystem*/ SS_MOUNT_ERROR:/* (-8)Failed to mount the filesystem*/ SS_COMMAND_ERROR:/* (-9)Drive not responding to command*/ SS_KERNEL_ERROR:/* (-10)Internal kernel error*/ SS_SIZE_ERROR:/* (-11)Drive size too small*/ SS_NO._PARTITION:/* (-12)The specified partition does not exist*/ SS_NO._FILE:/* (-13)Device file does not exist*/ Attempted to acquire HDD status through the driver but there has been no response for 30 seconds or more. | ||
Unformatted HDD Label data corrupted HDD defective | ||
Format the HDD (SP5-832: HDD formatting) through SP mode. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC862-00 | D | Number of the defective sector reaches the maximum count |
101 defective sectors are generated at the image storage area in the HDD. | ||
SC863 occurs during the HDD reading and defective sectors are registered up to 101. | ||
Format the HDD with SPSP5-832. Replace the HDD. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC863-01 | D | HDD data read failure |
The data written to the HDD cannot be read normally. | ||
Bad sectors were generated during operation. (An error occurred in an area that does not belong to a partition, such as the disk label area.) | ||
Guide for when to replace the HDD 1. When SC863 has occurred ten times or more The interval is short. Repeatedly occurs in the same situation (At power-on, etc.). Startup takes a long time when the main power is turned on. 2. It takes a long time after main power on for the operation panel to become ready. HDD access may be consuming time. Normal HDD access time after main power on is about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20 to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD, HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data and check them. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC863-02 to 23 | D | HDD data read failure |
The data written to the HDD cannot be read normally. | ||
Bad sectors were generated during operation. (An error occurred in partition "a" (SC863-02) to partition "v" (SC863-23)). | ||
Guide for when to replace the HDD 1. When SC863 has occurred ten times or more The interval is short. Repeatedly occurs in the same situation (At power-on, etc.). Startup takes a long time when the main power is turned on. 2. It takes a long time after main power on for the operation panel to become ready. HDD access may be consuming time. Normal HDD access time after main power on is about 5 seconds. If the machine is not waiting for the engine to be ready and it still takes 20 to 30 seconds or more, the HDD may be the cause. If there is a problem with the HDD, HDD-related SCs such as SC860 and SC863 will occur frequently. Print the SC log data and check them. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC864-00 | D | HD data CRC error |
During HD operation, the HD cannot respond to a CRC error query. Data transfer did not execute normally while data was being written to the HD. | ||
HD defective | ||
- |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC864-01 | D | HDD data CRC error |
During HDD operation, the HDD cannot respond to a CRC error query. Data transfer did not execute normally while data was being written to the HDD. | ||
Bad sectors were generated during operation. (An error occurred in an area that does not belong to a partition, such as the disk label area.) | ||
Format the HDD. Replace the HDD. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC864-02 to 23 | D | HDD data CRC error |
During HDD operation, the HDD cannot respond to a CRC error query. Data transfer did not execute normally while data was being written to the HDD. | ||
Bad sectors were generated during operation. (An error occurred in partition "a" (SC864-02) to partition "v" (SC864-23)). | ||
Format the HDD. Replace the HDD. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC865-00 | D | HD access error |
During HDD operation, the HDD returned an error. | ||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). | ||
Replace the HDD. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC865-01 | D | HDD access error |
During HDD operation, the HDD returned an error. | ||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in an area that does not belong to a partition, such as the disk label area.) | ||
Replace the HDD. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC865-02 to 23 | D | HDD access error |
During HDD operation, the HDD returned an error. | ||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). (An error occurred in partition "a" (SC865-02) to partition "v" (SC865-23)). | ||
Replace the HDD. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC865-50 to 73 | D | HDD time-out error |
The machine does not detect a reply from the HDD during the HDD operation. | ||
The HDD does not respond to the read/ write command from the machine. | ||
Check the harness connections between the controller board and HDD. Replace the HDD. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC866-00 | B | SD card authentication error |
A license error of an application that is started from the SD card was detected. | ||
Invalid program data is stored on the SD card. | ||
Store a valid program data on the SD card. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC867-00 | C | SD card removed |
The SD card was removed while the machine is on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd0). | ||
Turn the main power OFF/ON. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC867-01 | C | SD card removed |
The SD card was removed while the machine is on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd1). | ||
Turn the main power OFF/ON. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC867-02 | C | SD card removed |
The SD card was removed while the machine is on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd2). | ||
Turn the main power OFF/ON. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC868-** | SD card access error | |
SC868-00 | D | The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd0) |
SC868-01 | D | The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) |
SC868-02 | D | The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd2) |
SD card defective SD controller defective | ||
Slot number is displayed on the sub code. Detail code is described in SMC print can confirm the details of the error. -13 to -3: File system check error Otherwise (no code, -2) : Device access error | ||
SD card that starts an application 1. Turn the main power off and check the SD card insertion status. 2. If no problem is found, insert the SD card and turn the main power on. 3. If an error occurs, replace the SD card. 4. If the error persists even after replacing the SD card, replace the controller board. SD card for users 1. In case of a file system error, reformat the SD card (using the "SD Formatter" made by Panasonic).* In case of a device access error 1. Turn the main power off and check the SD card insertion status. 2. If no problem is found, insert the SD card and turn the main power on. 3. If an error occurs, use another SD card. 4. If the error persists even after replacing the SD card, replace the controller board. |
Service Call 816-899
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for firmware update by a customer engineer.
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC869-** | Malfunction of the proximity sensor (human detection sensor) is detected | |
SC869-01 | C | Continuously detecting malfunction |
The proximity sensor (human detection sensor) keeps in a detection state and accumulated time exceeds 24 hours. | ||
The proximity sensor (human detection sensor) is disabled and is in the detection state at all times. | ||
SC869-02 | C | Continuously non-detecting malfunction |
In the non-detection state, the following operations are detected 20 times continuously. Pressing "energy saver" key or touching the operation panel Opening/closing the plate cover or ADF Setting the original Opening the front cover Opening the paper feed tray | ||
The proximity sensor (human detection sensor) is disabled and is in the non-detection state at all times. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
1. Go to the SP5-102-203 (AutoDetect: HumanDetectSetting). 2. Cover the sensor with 10 sheets of plain paper, and then execute the SP. Make sure that it becomes "0". (Do not place your hand near the sensor, even over the paper, when covering the sensor) 3. Remove the paper from the sensor and make sure that it becomes "1". 4. If the sensor reacts normally in step 2 and 3, check if there are any other possible factors around the machine that may cause the temperature change such as a heater or a fan. (Deal with the issue as necessary) 5. Replace the proximity sensors (human detection sensors) and proximity sensor (human detection sensor) board if an abnormal value is detected during steps 2 and 3. 6. Turn on the main power on and perform steps 1, 2, and 3 again. 7. If the SC is not solved, turn the main power off and replace the harness which connects the proximity sensors (human detection sensors) and the proximity sensor (human detection sensor) board. 8. If the SC is still not solved, there is a possibility that other parts of the machine such as the connector at the controller side or the harness between proximity sensor (human detection sensor) board and IPU are broken. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC870-00 | B | Address Book data error (Anytime: Address Book Error.) |
SC870-01 | B | Address Book data error (On startup: Media required for storing the Address Book is missing.) |
SC870-02 | B | Address Book data error (On startup: encryption is configured but the module required for encryption (DESS) is missing.) |
SC870-03 | B | Address Book data error (Initialization: Failed to generate a file to store internal Address Book.) |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC870-04 | B | Address Book data error (Initialization: Failed to generate a file to store delivery sender.) |
SC870-05 | B | Address Book data error (Initialization: Failed to generate a file to store delivery destination.) |
SC870-06 | B | Address Book data error (Initialization: Failed to generate a file to store information required for LDAP search.) |
SC870-07 | B | Address Book data error (Initialization: Failed to initialize entries required for machine operation.) |
SC870-08 | B | Address Book data error (Machine configuration: HDD is present but the space for storing the Address Book is unusable.) |
SC870-09 | B | Address Book data error (Machine configuration: Inconsistency in the NVRAM area used for storing settings required for Address Book configuration.) |
SC870-10 | B | Address Book data error (Machine configuration: Cannot make a directory for storing the Address Book in the SD/USB FlashROM.) |
SC870-11 | B | Address Book data error (On startup: Inconsistency in Address Book entry number.) |
SC870-20 | B | Address Book data error (File I/O: Failed to initialize file.) |
SC870-21 | B | Address Book data error (File I/O: Failed to generate file.) |
SC870-22 | B | Address Book data error (File I/O: Failed to open file.) |
SC870-23 | B | Address Book data error (File I/O: Failed to write to file.) |
SC870-24 | B | Address Book data error (File I/O: Failed to read file.) |
SC870-25 | B | Address Book data error (File I/O: Failed to check file size.) |
SC870-26 | B | Address Book data error (File I/O: Failed to delete data.) |
SC870-27 | B | Address Book data error (File I/O: Failed to add data.) |
SC870-30 | B | Address Book data error (Search: Failed to obtain data from cache when searching in the machine Address Book. delivery destination/sender.) |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC870-31 | B | Address Book data error (Search: Failed to obtain data from cache during LDAP search.) |
SC870-32 | B | Address Book data error (Search: Failed to obtain data from cache while searching the WS-Scanner Address Book.) |
SC870-41 | B | Address Book data error (Cache: failed to obtain data from cache.) |
SC870-50 | B | Address Book data error (On startup: Detected abnormality of the Address Book encryption status.) |
SC870-51 | B | Address Book data error (Encryption settings: Failed to create directory required for conversion between plaintext and encrypted text.) |
SC870-52 | B | Address Book data error (Encryption settings: Failed to convert from plaintext to encrypted text.) |
SC870-53 | B | Address Book data error (Encryption settings: Failed to convert from encrypted text to plaintext.) |
SC870-54 | B | Address Book data error (Encryption settings: Detected data inconsistency when reading the encrypted Address Book.) |
SC870-55 | B | Address Book data error (Encryption settings: Failed to delete file when changing encryption setting.) |
SC870-56 | B | Address Book data error (Encryption settings: Failed to erase the file that records the encryption key during an attempt to change the encryption setting.) |
SC870-57 | B | Address Book data error (Encryption settings: Failed to move a file during an attempt to change the encryption setting.) |
SC870-58 | B | Address Book data error (Encryption settings: Failed to delete a directory during an attempt to change the encryption setting.) |
SC870-59 | B | Address Book data error (Encryption settings: Detected a resource shortage during an attempt to change the encryption setting.) |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC870-60 | B | Address Book data error (Unable to obtain the on/off setting for administrator authentication (06A and later).) |
When an error related to the Address Book is detected during startup or operation. | ||
Software bug Inconsistency of Address Book source location (machine/delivery server/LDAP server) Inconsistency of Address Book encryption setting or encryption key (NVRAM or HDD was replaced individually without formatting the Address Book) Address Book storage device (SD/HDD) was temporarily removed or hardware configuration does not match the application configuration. Address Book data corruption was detected. | ||
Install the device that contains address book information properly, and turn the main power off/on. If SC occurs again, do the following steps. 1. After installing the HDD, or SD/USB ROM, execute SP5-846-046 (UCS Setting). 2. Wait more than 3 seconds, then execute SP5-832 (HDD Formatting). 3. Turn the main power OFF/ON. Procedure after SC870 is cleared 1. If there is backup data in SD card or Web Image Monitor, restore the address book data. (To restore from SD card, enter the encryption password which is the same as when you enter to backup.) |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC871-00 | D | FCU error |
An error occurred when FCS detects FCU defective. | ||
Time-out error Abnormal Parameter | ||
Turn the main power OFF/ON. Update the firmware if more recent firmware was released. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC872-00 | B | HDD mail reception error |
An error was detected on the HDD immediately after the machine was turned on. | ||
HDD defective Power was turned off while the machine used the HDD. | ||
Format the HDD (SP5-832-007: HDD Formatting: Mail RX Data).). Replace the HDD. When you do the above, the following information will be initialized. Partly received partial mail messages. Already-read statuses of POP3-received messages (All messages on the mail server are handled as new messages). |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC873-00 | B | HDD mail reception error |
An error was detected on the HDD immediately after the machine was turned on. | ||
HDD defective Power was turned off while the machine used the HDD. | ||
Format the HDD (SP5-832-007 : HDD Formatting: Mail RX Data). Replace the HDD. When you do the above, the following information will be initialized. Sender’s mail text Default sender name/password (SMB/FTP/NCP) Administrator mail address Scanner delivery history |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC874-05 | D | Delete all error (Delete data area) : Read error |
SC874-06 | D | Delete all error (Delete data area) : Write error |
SC874-09 | D | Delete all error (Delete data area) : No response from HDD |
SC874-10 | D | Delete all error (Delete data area) : Error in Kernel |
SC874-12 | D | Delete all error (Delete data area) : No designated partition |
SC874-13 | D | Delete all error (Delete data area) : No device file |
SC874-14 | D | Delete all error (Delete data area) : Start option error |
SC874-15 | D | Delete all error (Delete data area) : No designated sector number |
SC874-16 | D | Delete all error (Delete data area) : failure in performing hdderase |
SC874-41 | D | Delete all error (Delete data area) : Other fatal errors |
SC874-42 | D | Delete all error (Delete data area) : End by cancellation |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC874-61 to -65 | D | Delete all error (Delete data area) : library error |
SC874-66 | D | Delete all error (Delete data area) : Unavailable |
SC874-67 | D | Delete all error (Delete data area) : Erasing not finished |
SC874-68 | D | Delete all error (Delete data area) : HDD format failure (Normal) |
SC874-69 | D | Delete all error (Delete data area) : HDD format failure (Abnormal) |
SC874-70 | D | Delete all error (Delete data area) : Unauthorized library |
SC874-99 | D | Delete all error (Delete data area) : other errors |
An error occurred while data was being erased on HDD or NVRAM. | ||
Error detected in HDD data delete program Error detected in NVRAM data delete program The "Delete All" option was not set | ||
Turn the main power switch off and back on, and then execute "Erase All Memory" under UP mode again. (However, if there is a defective sector or other problem with the hard disk, the error will persist even after trying the above.) If the "Delete All" option is not installed when this error occurs, install the option. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC875-01 | D | Delete all error (HDD erasure) (hddchack –i error) |
SC875-02 | D | Delete all error (HDD erasure) (Data deletion failure) |
An error was detected before HDD/data erasure starts. (Failed to erase data/failed to logically format HDD) | ||
HDD logical formatting failed. The modules failed to erase data. | ||
Turn the main power OFF/ON. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC876-00 | D | Log Data Error |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Damaged log data file. Log encryption is enabled but encryption module is not installed. Inconsistency of encryption key between NV-RAM and HDD. Software bug. | ||
Try the SC876-01 to -99 solutions listed below. If it is not solved, do the following steps (for when only an HDD is replaced): 1. Disconnect the HDD and turn ON the main power. 2. Execute SP5-801-019 (Memory Clear: LCS Memory Clr) to Initialize the LCS settings. 3. Turn OFF the main power. 4. Connect the HDD and turn ON the main power. 5. Execute SP5-832-004 (HDD Formatting (Job Log)). 6. Turn OFF the main power. * The following step is to configure the logging/encryption setting again. 7. Turn ON the main power. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC876-01 | D | Log Data Error 1 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Damaged log data file | ||
Initialize the HDD (SP5-832-004). |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC876-02 | D | Log Data Error 2 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Log encryption is enabled but encryption module is not installed. | ||
Replace or set again the encryption module. Disable the log encryption setting. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC876-03 | D | Log Data Error 3 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Inconsistency of encryption key between NV-RAM and HDD. | ||
Disable the log encryption setting. Initialize LCS memory (SP5801-019). Initialize the HDD (SP5-832-004). |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC876-04 | D | Log Data Error 4 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Log encryption key is disabled but the log data file is encrypted. (NVRAM data corruption) Log encryption key is enabled but the log data file is not encrypted. (NVRAM data corruption) | ||
Initialize the HDD (SP5-832-004). |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC876-05 | D | Log Data Error 5 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Only the NV-RAM has been replaced with one previously used in another machine. Only the HDD has been replaced with one previously used in another machine. | ||
Attach the original NV-RAM. Attach the original HDD. With the configuration that caused the SC, initialize the HDD (SP5-832-004). |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC876-99 | D | Log Data Error 99 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Other causes | ||
- |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC877-00 | B | Data Overwrite Security card error |
The "Auto Erase Memory" function of the Data Overwrite Security is set to on but it cannot be done. | ||
Data Overwrite Security option SD card is broken. Data Overwrite Security option SD card has been removed. | ||
If the SD card is broken, prepare a new Data Overwrite Security option SD card and replace the NVRAM. If the SD card has been removed, turn the main power off and reinstall a working Data Overwrite Security option SD card. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC878-00 | D | TPM authentication error |
TPM electronic recognition failure | ||
Update of system module attempted without correct update path USB flash memory not operating correctly | ||
Replace the controller board. |
Trusted Platform Module
In computing, Trusted Platform Module (TPM) is both the name of a published specification detailing a secure crypto processor that can store cryptographic keys that protect information, as well as the general name of implementations of that specification often called the "TPM chip" or "TPM Security Device" (as designated in certain Dell BIOS settings).
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC878-01 | D | USB flash error |
There is a problem in the file system of the USB flash memory. | ||
USB Flash system files corrupted | ||
Replace the controller board. |
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC878-02 | D | TPM error |
An error occurred in either TPM or the TPM driver | ||
TPM not operating correctly | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC878-03 | D | TCSD error |
An error occurred in the TPM software stack. | ||
TPM, TPM software cannot start A file required by TPM is missing | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC878-20 | D | Random number test error |
An error was detected when a random number table was generated during a self-test. The random number table is generated by TPM (Trusted Platform Module). The table generated by TPM failed the test. TPM (Trusted Platform Module) is a computer chip that can securely store information used to authenticate the platform. This information can include passwords, certificates, and encryption keys. | ||
TPM is defective | ||
Turn the main power OFF/ON. Replace the controller board. |
Troubleshooting
Troubleshooting
Troubleshooting
Service Call 816-899
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC880-00 | D | MLB error |
Reply to MLB access was not returned within a specified time. | ||
MLB defective | ||
Replace the MLB. Remove the MLB. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC881-01 | D | Management area error |
A problem was detected in the software This error may even occur is an IC card option is not installed. | ||
This is caused by accumulation of abnormal authentication information in the software. (User operation will not directly cause it.) At login Example: When a job is sent to the printer/when logged on from the operation panel/when logged on from a Web browser | ||
Turn the main power OFF/ON. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC899-00 | D | Software performance error (signal reception end) |
Unknown software error occurred. | ||
Occurs when an internal program behaves abnormally. | ||
In the case of a hardware defect Replace the hardware. In the case of a software error Turn the main power OFF/ON. Try updating the firmware. |