Image Adjustment


4.20.2 SCANNING

Check the printing registration/side-to-side adjustment and the blank margin adjustment before you do the following scanner adjustments.

Use a C4 test chart to do the following adjustments.


Scanner Sub-scan Magnification


image

A: Sub-scan magnification

1. Put the test chart on the exposure glass. Then make a copy from one of the feed stations.

2. Check the magnification ratio. Adjust with SP4-008 if necessary. Standard: ±1.0%.


Scanner Leading Edge and Side-to-side Registration


image

A: Leading Edge Registration

1. Put the test chart on the exposure glass. Then make a copy from one of the feed stations.

2. Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.

Standard: 0 ± 2mm for the leading edge registration, 0 ± 2.5mm for the side-to-side registration.

 

Scanner Sub-scan MagnificationScanner Leading Edge and Side-to-side Registration