HOME PAGE | < Previous | Contents | Next >
4.14.4 REVERSE SENSOR
1. Paper exit unit (page 4-145)
2. Reverse sensor unit [A]
When attaching the reverse sensor, if you screw too tightly in the direction of the blue arrow, it may cause the gap between the guide plates [A] to be too narrow, resulting in paper jams. Make sure that there is a gap [A] of 3mm or more after you fasten the screw.
3. Reverse
sensor [A]