HOME PAGE | < Previous | Contents | Next >

Key Counter Bracket Type M3 (D739-09)


Installation

Installation

Installation

2.33 KEY COUNTER BRACKET TYPE M3 (D739-09)


2.33.1 ACCESSORY CHECK


No.

Description

Q’ty

Remarks

-

Screw: M3X8

1


-

Binding Self-Tapping Screw: M4X8

3


-

Clamp:LWS-1211Z

2


-

Clamp:NK-3N

1


-

Double Sided Tape

2


-

Key Counter Plate Nut

2


-

Key Counter Harness

1



2.33.2 INSTALLATION PROCEDURE


When installing this option, turn OFF the main power and unplug the power cord from the wall socket. If installing without turning OFF the main power, an electric shock or a malfunction may occur.

1. Hold the key counter plate nuts [A] on the inside of the key counter bracket [B] and insert the key counter holder [C].

2. Secure the key counter holder to the bracket imagex2).

3. Install the key counter cover [D] imagex2).

Key Counter Bracket Type M3 (D739-09)


image

4. Open the right door.

5. Right rear cover [A] imagex4, among them, tapping screw x1)


image


When installing, insert the projections [A] in the holes [B], taking care not to trap the harness inside.

Installation

Installation

Installation

Key Counter Bracket Type M3 (D739-09)


image

6. Remove the rear cover [A].


image


7. Remove the controller box cover [A]. Red Circle: Remove / Blue Circle: Loosen

image

8. Route the key counter’s cable inside the machine and fasten it using the screw hole [A].

Key Counter Bracket Type M3 (D739-09)


image

9. Connect the key counter’s cable to the 4-pin connector [A] on the machine.

image

10. Attach the supplied clamp [A], and then route the cable as shown.


image

11. Open the slit in the rear cover to put the cable through, and then attach the rear cover while putting the cable through.

Installation

Installation

Installation

Key Counter Bracket Type M3 (D739-09)


image

12. Connect the key counter and cable.

13. Attach the key counter [A] to the machine’s rear right.

image

14. Reinstall all the covers on the main machine.

15. Peel off double sided tape on the key counter bracket and attach the key counter to the scanner right cover.

16. Reassemble the machine.

 