HOME PAGE | < Previous | Contents | Next >

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


1.2 G3 INTERFACE UNIT TYPE M19 (D3BV-07, -08, -12)


1.2.1 ACCESSORY CHECK

Check the quantity and condition of the accessories against the following list.


No.

Description

Q'ty

Remarks

1

SG3 Interface Unit

1


2

Telephone Cable

1

NA only

3

Ferrite Core

1


4

FFC

1


5

FFC Holder

1


6

Screw: M3x6

3


-

EMC Address Decal

1

EU only

-

FCC Decal

1

NA only



image


1.2.2 INSTALLATION PROCEDURE


Before installing this fax unit, print out all data in the printer buffer. Turn the main power OFF and disconnect the power cord and the network cable.

An additional two SG3 boards can be added for this model. Follow the procedures for installing a single SG3 board or double SG3 board as required.

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

Single G3 Board


If the Fax Option Type M19 is not installed in the machine, install the Fax Option Type M19 first (Link).

1. Remove the I/F cover [A].

image

2. Remove the rear cover [A].


image


3. Remove the controller box cover [A].

Red circle: Remove Blue circle: Loosen

image

4. Remove the "LINE2" [A] cover using a screwdriver.

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


image

5. Connect the FFC [A] to the FCU.

image

Release the connector lock [B] and connect the FFC, and then lock the FFC.

Connect the folded side [C] as shown below.


image

6. Install the SG3 interface unit [A].

Insert the tab [C] of the controller box into the cutout [B] of the SG3 interface unit.

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


image

Insert the tab [D] of the controller box into the cutout of the SG3 interface unit [E].


image

7. Take the FFC [A] out and connect the CCU interface board connector [B].


image

8. Secure the FFC [B] with the supplied clamp [A].

Make sure that the FFC is connected securely.

G3 Interface Unit Type M19 (D3BV-07, -08, -12)



image

9. Reinstall the controller box cover, rear cover and I/F cover.

10. Make two loops with the telephone cord, and then attach the ferrite core [A].


image

11. Connect the telephone cord to the "LINE 2" jack.

12. Attach the clamps [A] to the rear cover of the optional paper feed unit, and then hold the telephone line with the clamps as shown below.

image

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

13. Insert the power plug into the outlet. Turn ON the main power of the machine.

14. Enter the service mode. Set Bit 1 of Communication Switch 16 to "1" (SP1-104-023).

15. Exit the service mode.

16. Turn the main power OFF then ON.

17. Print out the system parameter list. Check that "G3" is displayed as an option.

18. Set up and program the items required for PSTN-2 communications.


Double G3 Boards


If the Fax Option Type M19 is not installed in the machine, install the Fax Option Type M19 first. (Link).

1. Remove the I/F cover [A].

image

2. Remove the rear cover [A].


image


3. Remove the controller box cover [A].

Red circle: Remove Blue circle: Loosen

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


image

4. Remove the "LINE2" [A] and "LINE3" [B] covers using a screwdriver.

image

5. Remove the CCU I/F board and SG3 board [A] from the SG3 interface unit.

Repeat the same procedure for the second SG3 interface unit.

image

6. Remove the SG3 board [A] from one of the CCU I/F and SG3 board assemblies removed in step 5.

7. Attach the SG3 board removed in step 6 to the other CCU I/F and SG3 board assembly [B].

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


image


8. Attach the boards (CCU I/F board and two SG3 boards) to the SG3 interface unit bracket.

Use two screws from the six screws removed in step 5.


image

9. Connect the FFC [A] to the FCU.

image

Release the connector lock [B] and connect the FFC, and then lock the FFC.

Connect the folded side [C] as shown below.

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


image

10. Install the SG3 interface unit [A].

Insert the tab [C] of the controller box into the cutout [B] of the SG3 interface unit.


image

Insert the tab [D] of the controller box into the cutout of the SG3 interface unit [E].


image

11. Take the FFC [A] out and connect the CCU interface board connector [B].

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

FAX OPTION M19 (D3DV) FOR D243/D244

G3 Interface Unit Type M19 (D3BV-07, -08, -12)


image

12. Secure the FFC [B] with a supplied clamp [A].

Make sure that the FFC is connected securely.


image

13. Reinstall the controller box cover, rear cover and I/F cover.

14. Make two loops with the telephone cord for each telephone line (LINE2, LINE3). Attach the ferrite core [A] to each telephone line.

image

15. Connect the telephone cords to the "LINE2" and "LINE3" jacks.

16. Attach the clamps [A] to the rear cover of the optional paper feed unit, and then hold the telephone lines with the clamps as shown below.