HOME PAGE | < Previous | Contents | Next >

Adjustment after ADF Replacement


SPDF DF3100 (D3B0)

SPDF DF3100 (D3B0)

SPDF DF3100 (D3B0)

1.8.3 CHECKING SKEW

1. Make sure that the difference between both end positions of the line [A] that you wrote on the original (see above) is within 0±2mm.

2. If not within the standard, change the position of the fixing screw [A] to the long hole

[B] at the right hinge.


image


1.8.4 CHECKING MAGNIFICATION

1. Copy the original and make sure that the length of the line [B] that you wrote on the original (see above) is within 100±1mm.

2. If not within the standard, adjust with the SP mode.

SP6-017-001 (DF Magnification Adj.)


1.8.5 PLATEN ADJUSTMENT

1. Open the ADF and remove the white cover [A].

image

2. Put the white cover [A] in the correct position on the exposure glass, aligning it with the glass cover [B] and the rear scale [C].

Adjustment after ADF Replacement


image

image

3. Close the ADF [A] slowly and attach the ADF to the white cover [B] with the hook and loop fastener.