HOME PAGE | < Previous | Contents | Next >
Adjustment after ADF Replacement
SPDF DF3100 (D3B0)
SPDF DF3100 (D3B0)
SPDF DF3100 (D3B0)
1.8.3 CHECKING SKEW
1. Make sure that the difference between both end positions of the line [A] that you wrote on the original (see above) is within 0±2mm.
2. If not within the standard, change the position of the fixing screw [A] to the long hole
[B] at the right hinge.
1.8.4 CHECKING MAGNIFICATION
1. Copy the original and make sure that the length of the line [B] that you wrote on the original (see above) is within 100±1mm.
2. If not within the standard, adjust with the SP mode.
SP6-017-001 (DF Magnification Adj.)
1.8.5 PLATEN ADJUSTMENT
1. Open the ADF and remove the white cover [A].
2. Put the white cover [A] in the correct position on the exposure glass, aligning it with the glass cover [B] and the rear scale [C].
Adjustment after ADF Replacement
3. Close the ADF [A] slowly and attach the ADF to the white cover [B] with the hook and loop fastener.