HOME PAGE | < Previous | Contents | Next >
5-804-245 | Bank: Tray4: Transport Mt: Standard Speed | ENG | |
5-804-246 | Bank: Tray5: Transport Mt: Standard Speed | ENG | |
5804 | [OUTPUT Check] | ||
Drives specified motor for a certain period of time to test operation. | |||
5-804-247 | Bank: Tray3: PU Solenoid | ENG | [0 or 1 / 0 / 1/step] |
5-804-248 | Bank: Tray4: PU Solenoid | ENG | |
5-804-249 | Bank: Tray5: PU Solenoid | ENG |
ADF
6008 | [ADF OUTPUT Check] | ||
Checks operation of the load of ADF. | |||
6-008-003 | Feed Motor Forward | ENG | [0 or 1 / 0 / 1/step] |
Rotates paper feed motor forward. | |||
6-008-004 | Feed Motor Reverse | ENG | [0 or 1 / 0 / 1/step] |
Rotates paper feed motor backward. | |||
6-008-005 | Relay Motor Forward | ENG | [0 or 1 / 0 / 1/step] |
Rotates carry motor forward. | |||
6-008-006 | Relay Motor Reverse | ENG | [0 or 1 / 0 / 1/step] |
Rotates carry motor backward. | |||
6-008-011 | Inverter Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Interval drives reverse solenoid. | |||
6-008-012 | Stamp | ENG | [0 or 1 / 0 / 1/step] |
Interval drives DONE stamp. | |||
6-008-013 | Fan Motor | ENG | [0 or 1 / 0 / 1/step] |
Input and Output Check
Interval drives FAN motor. | |||
6-008-014 | Feed Clutch | ENG | [0 or 1 / 0 / 1/step] |
Interval drives paper feed clutch. | |||
6-008-015 | Feed Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Interval drives paper feed solenoid. |
6012 | [1-Pass ADF OUTPUT Check] | ||
For Single-Pass simultaneous duplex models only. | |||
6-012-001 | Pick-Up Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF pick up motor. | |||
6-012-003 | Feed Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper feed motor. | |||
6-012-005 | Relay Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper carry motor. | |||
6-012-009 | Exit Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper exit motor. | |||
6-012-010 | Bottom Plate Motor For/Rev | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Moves up/down the bottom plate by driving the ADF bottom plate motor forward, backward. |
Engine SP Mode Tables
Engine SP Mode Tables
Engine SP Mode Tables