HOME PAGE | < Previous | Contents | Next >
Key Counter Interface Unit Installation
2.17 KEY COUNTER INTERFACE UNIT INSTALLATION
2.17.1 INSTALLATION PROCEDURE
1. Rear cover [1] x 6)
2. Install the key counter interface board in the location [2] x 4).
3. Connect the harness to CN3 on the key counter interface board.
4. Connect the other terminal of the harness to CN214 [3] on the IOB x 3).
Key Counter Interface Unit Installation
Installation
Installation
Installation
5. Cut off the part [4] of the rear cover.
6. Connect the harness from the counter device to CN4 on the key counter interface board and clamp it with three clamps [5].
7. Reassemble the machine.