HOME PAGE | < Previous | Contents | Next >
3.1 DIP SWITCHES
DIP-SW | Function | |||
1 | 2 | 3 | 4 | |
0 | 0 | 0 | 0 | Normal operating mode (Default) |
0 | 0 | 0 | 1 | Free run: With original: One-sided mode: 100% speed |
0 | 0 | 1 | 0 | Free run: With original: Two-sided mode: 100% speed |
0 | 0 | 1 | 1 | Free run: No original: One-sided mode: 100% speed |
0 | 1 | 0 | 0 | Free run: No original: Two-sided mode: 100% speed |
0 | 1 | 0 | 1 | Free run: With original: One-sided mode: 32% speed |
0 | 1 | 1 | 0 | Free run: With original: Two-sided mode: 32% speed |
0 | 1 | 1 | 1 | Free run: With original: One-sided mode: 70% speed |
1 | 0 | 0 | 0 | Free run: With original: Two-sided mode: 70% speed |
1 | 0 | 0 | 1 | Free run: With original: One-sided mode: 200% speed |
1 | 0 | 1 | 0 | Free run: With original: Two-sided mode: 200% speed |
1 | 0 | 1 | 1 | Transport Motor On |
1 | 1 | 0 | 0 | Feed Motor On |
1 | 1 | 0 | 1 | Transport Motor On with random mode |
1 | 1 | 1 | 0 | Feed Motor On with random mode |
1 | 1 | 1 | 1 |